Fault-Tolerant Control for Single-Phase Open-Circuit and Short-Circuit Fault in Five-Phase PMSM With Third-Order Harmonic Back EMF Using Coefficients Reconfiguration

被引:4
|
作者
Wang, Huanran [1 ]
Gu, Chunyang [1 ,2 ]
Zhao, Weiduo [1 ]
Wang, Shuo [1 ]
Zhang, Xiaochen [3 ,4 ]
Buticchi, Giampaolo [1 ]
Gerada, Chris [5 ]
Zhang, He [1 ]
机构
[1] Univ Nottingham Ningbo China, Key Lab More Elect Aircraft Technol Zhejiang Prov, Ningbo 315100, Peoples R China
[2] Yongjiang Lab, Adv Elect Machine Drive Res Ctr, Ningbo 315202, Peoples R China
[3] Yongjiang Lab, Ningbo 315202, Peoples R China
[4] Univ Nottingham Ningbo China, Nottingham Ningbo China Beacons Excellence Res & I, Ningbo 315100, Peoples R China
[5] Univ Nottingham, Nottingham NG7 2RD, England
基金
中国国家自然科学基金;
关键词
Harmonic analysis; Torque; Fault tolerant systems; Fault tolerance; Circuit faults; Fluctuations; Impedance; Fault tolerant control; Open-circuit (OC) fault; Short-circuit (SC) fault; Third-order harmonic back EMF; Coefficients reconfiguration; MULTIPHASE INDUCTION-MOTOR; PERMANENT-MAGNET MOTOR; SYNCHRONOUS MOTOR; CURRENT INJECTION; TORQUE CONTROL; MACHINES; DESIGN;
D O I
10.1109/TEC.2023.3327507
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
For a five-phase permanent magnet synchronous machine (PMSM), the third-order harmonic back EMF is increased by changing the shape of the permanent magnet for increasing average torque in healthy operation. Additionally, in the open-circuit (OC) and short-circuit (SC) faults, the effect of injected third-order harmonic back EMF also needs to be considered. Therefore, this paper proposes a fault-tolerant control method with original transformation matrixes and coefficients reconfiguration in fundamental and third-order harmonic subspaces for both single-phase OC and SC faults. Fault tolerance can be applied by reconfiguring the relative coefficients after an OC or SC fault occurs, depending on the type of fault. Besides, the proposed method aims to optimize the OC fault tolerance strategies and effectively solve the single-phase SC fault, considering the influence in the third-order harmonic back EMF. According to experimental results, the torque fluctuation after applying the proposed method is similar to that in the healthy stage and much lower than that using most fault-tolerant control methods without considering the third-order harmonic back EMF.
引用
收藏
页码:782 / 792
页数:11
相关论文
共 50 条
  • [1] Fault-Tolerant SVPWM Control Strategy for Five-Phase PMSM under Single-Phase Open-Circuit Fault
    Chen Yiguang
    Bao Zhenmao
    Lin Chenghan
    Zhao Xiaobin
    INNOVATIVE SOLUTIONS FOR ENERGY TRANSITIONS, 2019, 158 : 2605 - 2610
  • [2] Open-Circuit Fault-Tolerant Control for Nonsinusoidal Back EMF Five-Phase PMSM With Copper Loss Reduction
    Wang, Huanran
    Gu, Chunyang
    Zhao, Weiduo
    Wang, Shuo
    Zhao, Han
    Buticchi, Giampaolo
    Gerada, Chris
    Zhang, He
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2024, 71 (07) : 6524 - 6533
  • [3] Short-circuit fault-tolerant control for five-phase fault-tolerant permanent magnet motors with trapezoidal back-EMF
    Chen, Qian
    Xia, Yuhang
    Wang, Jiabin
    Zhao, Wenxiang
    Liu, Guohai
    FUNDAMENTAL RESEARCH, 2022, 2 (06): : 964 - 973
  • [4] Open-circuit Fault Tolerant Control of Five-Phase Permanent Magnet Motors with Third-Harmonic Back-EMF
    Dwari, Suman
    Parsa, Leila
    IECON 2008: 34TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, VOLS 1-5, PROCEEDINGS, 2008, : 3010 - 3015
  • [5] Sensorless Speed Control of Five-Phase PMSM Drives in Case of a Single-Phase Open-Circuit Fault
    Saleh, Kamel
    Sumner, Mark
    IRANIAN JOURNAL OF SCIENCE AND TECHNOLOGY-TRANSACTIONS OF ELECTRICAL ENGINEERING, 2019, 43 (03) : 501 - 517
  • [6] Sensorless Speed Control of Five-Phase PMSM Drives in Case of a Single-Phase Open-Circuit Fault
    Kamel Saleh
    Mark Sumner
    Iranian Journal of Science and Technology, Transactions of Electrical Engineering, 2019, 43 : 501 - 517
  • [7] Fault-Tolerant Operation of an Open-End Winding Five-Phase PMSM Drive With Short-Circuit Inverter Fault
    Ngac Ky Nguyen
    Meinguet, Fabien
    Semail, Eric
    Kestelyn, Xavier
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2016, 63 (01) : 595 - 605
  • [8] Rotor-Flux Observer Based Sensorless Control of Five-Phase Fault-Tolerant PMSM with Open-Circuit Fault
    Zhou H.
    Ye C.
    Chen C.
    Zhang D.
    Chen Q.
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2023, 38 (02): : 422 - 434
  • [9] Online Full Range Copper Loss Minimization for Single-Phase Short-Circuit Fault Tolerant Control in Five-Phase PMSM
    Wang, Huanran
    Gu, Chunyang
    Zhao, Weiduo
    Wang, Shuo
    Zhang, Xiaochen
    Buticchi, Giampaolo
    Gerada, Chris
    Zhang, He
    IEEE TRANSACTIONS ON TRANSPORTATION ELECTRIFICATION, 2024, 10 (02): : 2777 - 2788
  • [10] Single-Phase Open-Circuit Fault-Tolerant Control for a Dual Five-Phase Permanent Magnet Motor With Multioperational Modes
    Liu, Yu
    Chen, Qian
    Chen, Shulong
    Ding, Wenqiang
    Liu, Guohai
    Zhao, Wenxiang
    IEEE TRANSACTIONS ON TRANSPORTATION ELECTRIFICATION, 2024, 10 (04): : 9591 - 9600