Lab-made 3D-printed electrochemical sensors for tetracycline determination

被引:30
作者
Lopes, Carlos E. C. [1 ]
de Faria, Lucas V. [2 ]
Araujo, Diele A. G. [3 ]
Richter, Eduardo M. [2 ]
Paixao, Thiago R. L. C. [3 ]
Dantas, Luiza M. F. [1 ]
Munoz, Rodrigo A. A. [2 ]
da Silva, Iranaldo S. [1 ]
机构
[1] Univ Fed Maranhao, Chem Technol Dept, BR-65080805 Sao Luis, MA, Brazil
[2] Univ Fed Uberlandia, Inst Chem, BR-38408100 Uberlandia, MG, Brazil
[3] Univ Sao Paulo, Inst Chem, Dept Fundamental Chem, BR-05508000 Sao Paulo, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
3D-printing; Conductive filament; Antibiotic; Batch injection analysis; Amperometry; GLASSY-CARBON ELECTRODE; FLOW-INJECTION; AMPEROMETRIC DETERMINATION; RESIDUES; MONTMORILLONITE; MILK;
D O I
10.1016/j.talanta.2023.124536
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Antibiotics such as tetracycline (TC) are widely prescribed to treat humans or dairy animals. Therefore, it is important to establish affordable devices in laboratories with minimal infrastructure. 3D printing has proven to be a powerful and cost-effective tool that revolutionizes many applications in electrochemical sensing. In this work, we employ a conductive filament based on graphite (Gr) and polylactic acid (PLA) (40:60; w/w; synthesized in our lab) to manufacture 3D-printed electrodes. This electrode was used "as printed" and coupled to batch injection analysis with amperometric detection (BIA-AD) for TC sensing. Preliminary studies by cyclic voltammetry and differential pulse voltammetry revealed a mass transport governed by adsorption of the species and consequent fouling of the redox products on the 3D printed surface. Thus, a simple strategy (solution stirring and application of successive potentials, +0.95 V followed by +1.2 V) was associated with the BIA-AD system to solve this effect. The proposed electrode showed analytical performance comparable to costly conventional electrodes with linear response ranging from 0.5 to 50 mu mol L-1 and a detection limit of 0.19 mu mol L-1. Additionally, the developed method was applied to pharmaceutical, tap water, and milk samples, which required minimal sample preparation (simple dilution). Recovery values of 92-117% were obtained for tap water and milk samples, while the content found of TC in the capsule was close to the value reported by the manufacturer. These results indicate the feasibility of the method for routine analysis involving environmental, pharmaceutical, and food samples.
引用
收藏
页数:8
相关论文
共 56 条
[21]   A novel Pb-poly aminophenol glassy carbon electrode for determination of tetracycline by adsorptive differential pulse cathodic stripping voltammetry [J].
Dizavandi, Zeinab Rajab ;
Aliakbar, Alireza ;
Sheykhan, Mehdi .
ELECTROCHIMICA ACTA, 2017, 227 :345-356
[22]   Reduced graphene oxide/ZnO nanocomposite modified electrode for the detection of tetracycline [J].
Durovic, Ana ;
Stojanovic, Zorica ;
Bytesnikova, Zuzana ;
Kravic, Snezana ;
Svec, Pavel ;
Pribyl, Jan ;
Richtera, Lukas .
JOURNAL OF MATERIALS SCIENCE, 2022, 57 (09) :5533-5551
[23]  
Faria LV, 2019, ANAL METHODS-UK, V11, P5328, DOI [10.1039/C9AY01759C, 10.1039/c9ay01759c]
[24]   Determination of Tetracycline on the Surface of a High-Performance Graphene Modified Screen-Printed Carbon Electrode in Milk and Honey Samples [J].
Filik, Hayati ;
Avan, Asiye A. ;
Aydar, Sevda ;
Ozyurt, Dilek ;
Demirata, Birsen .
CURRENT NANOSCIENCE, 2016, 12 (04) :527-533
[25]   Determination of Tetracyclines in Bovine and Human Urine using a Graphite-Polyurethane Composite Electrode [J].
Fioramonti Calixto, Carolina Maria ;
Gomes Cavalheiro, Eder Tadeu .
ANALYTICAL LETTERS, 2015, 48 (09) :1454-1464
[26]   An amperometric FIA system with carrier recycling: an environmentally friendly approach for atenolol determination in pharmaceutical formulations [J].
Franco, M. A. ;
Araujo, D. A. G. ;
Oliveira, L. H. ;
Trindade, M. A. G. ;
Takeuchi, R. M. ;
Santos, A. L. .
ANALYTICAL METHODS, 2016, 8 (48) :8420-8426
[27]   Accurate determination of four tetracycline residues in chicken meat by isotope dilution-liquid chromatography/tandem mass spectrometry [J].
Gab-Allah, Mohamed A. ;
Lijalem, Yared Getachew ;
Yu, Hyeonwoo ;
Lim, Dong Kyu ;
Ahn, Seonghee ;
Choi, Kihwan ;
Kim, Byungjoo .
JOURNAL OF CHROMATOGRAPHY A, 2023, 1691
[28]   Simple and novel electrochemical sensor for the determination of tetracycline based on iron/zinc cations-exchanged montmorillonite catalyst [J].
Gan, Tian ;
Shi, Zhaoxia ;
Sun, Junyong ;
Liu, Yanming .
TALANTA, 2014, 121 :187-193
[29]   Recent Advances in Analytical Chemistry by 3D Printing [J].
Gross, Bethany ;
Lockwood, Sarah Y. ;
Spence, Dana M. .
ANALYTICAL CHEMISTRY, 2017, 89 (01) :57-70
[30]   Magnetic solid phase extraction based on phenyl silica adsorbent for the determination of tetracyclines in milk samples by capillary electrophoresis [J].
Ibarra, Israel S. ;
Rodriguez, Jose A. ;
Miranda, Jose M. ;
Vega, Marisol ;
Barrado, Enrique .
JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (16) :2196-2202