Lab-made 3D-printed electrochemical sensors for tetracycline determination

被引:30
作者
Lopes, Carlos E. C. [1 ]
de Faria, Lucas V. [2 ]
Araujo, Diele A. G. [3 ]
Richter, Eduardo M. [2 ]
Paixao, Thiago R. L. C. [3 ]
Dantas, Luiza M. F. [1 ]
Munoz, Rodrigo A. A. [2 ]
da Silva, Iranaldo S. [1 ]
机构
[1] Univ Fed Maranhao, Chem Technol Dept, BR-65080805 Sao Luis, MA, Brazil
[2] Univ Fed Uberlandia, Inst Chem, BR-38408100 Uberlandia, MG, Brazil
[3] Univ Sao Paulo, Inst Chem, Dept Fundamental Chem, BR-05508000 Sao Paulo, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
3D-printing; Conductive filament; Antibiotic; Batch injection analysis; Amperometry; GLASSY-CARBON ELECTRODE; FLOW-INJECTION; AMPEROMETRIC DETERMINATION; RESIDUES; MONTMORILLONITE; MILK;
D O I
10.1016/j.talanta.2023.124536
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Antibiotics such as tetracycline (TC) are widely prescribed to treat humans or dairy animals. Therefore, it is important to establish affordable devices in laboratories with minimal infrastructure. 3D printing has proven to be a powerful and cost-effective tool that revolutionizes many applications in electrochemical sensing. In this work, we employ a conductive filament based on graphite (Gr) and polylactic acid (PLA) (40:60; w/w; synthesized in our lab) to manufacture 3D-printed electrodes. This electrode was used "as printed" and coupled to batch injection analysis with amperometric detection (BIA-AD) for TC sensing. Preliminary studies by cyclic voltammetry and differential pulse voltammetry revealed a mass transport governed by adsorption of the species and consequent fouling of the redox products on the 3D printed surface. Thus, a simple strategy (solution stirring and application of successive potentials, +0.95 V followed by +1.2 V) was associated with the BIA-AD system to solve this effect. The proposed electrode showed analytical performance comparable to costly conventional electrodes with linear response ranging from 0.5 to 50 mu mol L-1 and a detection limit of 0.19 mu mol L-1. Additionally, the developed method was applied to pharmaceutical, tap water, and milk samples, which required minimal sample preparation (simple dilution). Recovery values of 92-117% were obtained for tap water and milk samples, while the content found of TC in the capsule was close to the value reported by the manufacturer. These results indicate the feasibility of the method for routine analysis involving environmental, pharmaceutical, and food samples.
引用
收藏
页数:8
相关论文
共 56 条
[1]  
Age^ncia Nacional de Vigila^ncia Sanitaria - Anvisa PAMVetmonit, 2007, RES LEIT EXP AO CONS
[2]   Voltammetric and spectrophotometric studies of toxic disinfection by-product 2,6-dichloro-1,4-benzoquinone and its behavior with DNA [J].
Aguiar, Allan Carlos S. ;
Veloso, William B. ;
da Silva, Iranaldo S. ;
Tanaka, Auro A. ;
Dantas, Luiza Maria F. .
CHEMICAL PAPERS, 2022, 76 (01) :575-583
[3]   Chemiluminescence Determination of Tetracyclines via Aluminum Sensitized Fluorescence [J].
Anastasopoulos, Panagiotis ;
Timotheou-Potamia, Meropi .
ANALYTICAL LETTERS, 2011, 44 (1-3) :25-37
[4]  
[Anonymous], 2018, COND PLA PROT PAST S
[5]  
Bard A.J., 2022, ELECTROCHEMICAL METH
[6]   Development of a highly sensitive xanthine oxidase-based biosensor for the determination of antioxidant capacity in Amazonian fruit samples [J].
Becker, Magda Marcia ;
Ribeiro, Eliane Braga ;
Brasil de Oliveira Marques, Paulo Roberto ;
Marty, Jean-Louis ;
Nunes, Gilvanda Silva ;
Catanante, Gaelle .
TALANTA, 2019, 204 :626-632
[7]   Designing and fabrication of a novel sensitive electrochemical aptasensor based on poly (L-glutamic acid)/MWCNTs modified glassy carbon electrode for determination of tetracycline [J].
Benvidi, Ali ;
Yazdanparast, Samira ;
Rezaeinasab, Masoud ;
Tezerjani, Marzieh Dehghan ;
Abbasi, Saleheh .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2018, 808 :311-320
[8]   Flow injection amperometric determination of procaine in pharmaceutical formulation using a screen-printed carbon electrode [J].
Bergamini, Marcio F. ;
Santos, Andre L. ;
Stradiotto, Nelson R. ;
Zanoni, Maria Valnice B. .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 43 (01) :315-319
[9]   3D Printed Graphene Electrodes' Electrochemical Activation [J].
Browne, Michelle P. ;
Novotny, Filip ;
Sofer, Zdenek ;
Pumera, Martin .
ACS APPLIED MATERIALS & INTERFACES, 2018, 10 (46) :40294-40301
[10]  
Calixto CMF, 2012, J BRAZIL CHEM SOC, V23, P938, DOI 10.1590/S0103-50532012000500020