Towards Automated and High-Throughput Quantitative Sizing and Isotopic Analysis of Nanoparticles via Single Particle-ICP-TOF-MS

被引:8
|
作者
Manard, Benjamin T. T. [1 ]
Bradley, Veronica C. C. [1 ]
Quarles, C. Derrick [2 ]
Hendriks, Lyndsey [3 ]
Dunlap, Daniel R. R. [1 ]
Hexel, Cole R. R. [1 ]
Sullivan, Patrick [2 ]
Andrews, Hunter B. B. [4 ]
机构
[1] Oak Ridge Natl Lab, Chem Sci Div, Oak Ridge, TN 37831 USA
[2] Elemental Sci Inc, Omaha, NE 68122 USA
[3] TOFWERK AG, CH-3645 Thun, Switzerland
[4] Oak Ridge Natl Lab, Radioisotope Sci & Technol Div, Oak Ridge, TN 37831 USA
关键词
nanoparticles; automated; high throughput; single particle; ICP-TOF-MS; SP-ICP-MS; PLASMA-MASS SPECTROMETRY; INTRODUCTION SYSTEM; SIZE;
D O I
10.3390/nano13081322
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The work described herein assesses the ability to characterize gold nanoparticles (Au NPs) of 50 and 100 nm, as well as 60 nm silver shelled gold core nanospheres (Au/Ag NPs), for their mass, respective size, and isotopic composition in an automated and unattended fashion. Here, an innovative autosampler was employed to mix and transport the blanks, standards, and samples into a high-efficiency single particle (SP) introduction system for subsequent analysis by inductively coupled plasma-time of flight-mass spectrometry (ICP-TOF-MS). Optimized NP transport efficiency into the ICP-TOF-MS was determined to be >80%. This combination, SP-ICP-TOF-MS, allowed for high-throughput sample analysis. Specifically, 50 total samples (including blanks/standards) were analyzed over 8 h, to provide an accurate characterization of the NPs. This methodology was implemented over the course of 5 days to assess its long-term reproducibility. Impressively, the in-run and day-to-day variation of sample transport is assessed to be 3.54 and 9.52% relative standard deviation (%RSD), respectively. The determination of Au NP size and concentration was of <5% relative difference from the certified values over these time periods. Isotopic characterization of the Ag-107/Ag-109 particles (n = 132,630) over the course of the measurements was determined to be 1.0788 +/- 0.0030 with high accuracy (0.23% relative difference) when compared to the multi-collector-ICP-MS determination.
引用
收藏
页数:12
相关论文
共 47 条
  • [31] Development of a MALDI-TOF MS Strategy for the High-Throughput Analysis of Biomarkers: On-Target Aptamer Immobilization and Laser-Accelerated Proteolysis
    Zhang, Xueyang
    Zhu, Shaochun
    Xiong, Ya
    Deng, Chunhui
    Zhang, Xiangmin
    ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2013, 52 (23) : 6055 - 6058
  • [32] APPLICATION OF MAGNETIC NANOPARTICLES IN HIGH-THROUGHPUT SINGLE NUCLEOTIDE POLYMORPHLSMS (SNPs) AND COPY NUMBER VARIATIONS (CNVs) ANALYSIS
    He Nongyue
    PROGRESS ON POST-GENOME TECHNOLOGIES AND MODERN NATURAL PRODUCTS, 2011, 2011, : 24 - 26
  • [33] High-Throughput Sulfide Sensing with Colorimetric Analysis of Single Au-Ag Core-Shell Nanoparticles
    Hao, Jinrui
    Xiong, Bin
    Chen, XiaoDong
    He, Yan
    Yeung, Edward S.
    ANALYTICAL CHEMISTRY, 2014, 86 (10) : 4663 - 4667
  • [34] A quantitative nanoparticle extraction method for microsecond time resolved single-particle ICP-MS data in the presence of a high background
    Mozhayeva, Darya
    Engelhard, Carsten
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2019, 34 (08) : 1571 - 1580
  • [35] Capillary array reversed-phase liquid chromatography-based multidimensional separation system coupled with MALDI-TOF-TOF-MS detection for high-throughput proteome analysis
    Gu, Xue
    Deng, Chunhui
    Yan, Guoquan
    Zhang, Xiangmin
    JOURNAL OF PROTEOME RESEARCH, 2006, 5 (11) : 3186 - 3196
  • [36] Can ultrafast single-particle analysis using ICP-MS affect the detection limit? Case study: Silver nanoparticles
    Mestek, Oto
    Loula, Martin
    Kana, Antonin
    Vosmanska, Magda
    TALANTA, 2020, 210
  • [37] Single-particle/Cell Analysis by Highly Time-resolved ICP-MS Using a High-efficiency Sample Introduction System
    Myashita, Shin-ichi
    Fujii, Shin-ichiro
    Inagaki, Kazumi
    BUNSEKI KAGAKU, 2017, 66 (09) : 663 - 676
  • [38] Quantitative analysis of underivatized 17 β-estradiol using a high-throughput LC-MS/MS assay - Application to support a pharmacokinetic study in ovariectomized guinea pigs
    Gandhi, Adarsh
    Matta, Murali K.
    Stewart, Sharron
    Chockalingam, Ashok
    Knapton, Alan
    Rouse, Rodney
    Wu, Wendy
    Patel, Vikram
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2020, 178
  • [39] High-Throughput Single-Particle Analysis of Metal-Enhanced Fluorescence in Free Solution Using Ag@SiO2 Core-Shell Nanoparticles
    Yang, Ya
    Meng, Lingyan
    Zhang, Wenqiang
    Zheng, Yan
    Wang, Shuo
    Ren, Bin
    Yang, Zhilin
    Yan, Xiaomei
    ACS SENSORS, 2017, 2 (09): : 1369 - 1376
  • [40] High-throughput and simultaneous quantitative analysis of homocysteine–methionine cycle metabolites and co-factors in blood plasma and cerebrospinal fluid by isotope dilution LC–MS/MS
    Seu Ping Guiraud
    Ivan Montoliu
    Laeticia Da Silva
    Loïc Dayon
    Antonio Núñez Galindo
    John Corthésy
    Martin Kussmann
    Francois-Pierre Martin
    Analytical and Bioanalytical Chemistry, 2017, 409 : 295 - 305