Towards Automated and High-Throughput Quantitative Sizing and Isotopic Analysis of Nanoparticles via Single Particle-ICP-TOF-MS

被引:8
|
作者
Manard, Benjamin T. T. [1 ]
Bradley, Veronica C. C. [1 ]
Quarles, C. Derrick [2 ]
Hendriks, Lyndsey [3 ]
Dunlap, Daniel R. R. [1 ]
Hexel, Cole R. R. [1 ]
Sullivan, Patrick [2 ]
Andrews, Hunter B. B. [4 ]
机构
[1] Oak Ridge Natl Lab, Chem Sci Div, Oak Ridge, TN 37831 USA
[2] Elemental Sci Inc, Omaha, NE 68122 USA
[3] TOFWERK AG, CH-3645 Thun, Switzerland
[4] Oak Ridge Natl Lab, Radioisotope Sci & Technol Div, Oak Ridge, TN 37831 USA
关键词
nanoparticles; automated; high throughput; single particle; ICP-TOF-MS; SP-ICP-MS; PLASMA-MASS SPECTROMETRY; INTRODUCTION SYSTEM; SIZE;
D O I
10.3390/nano13081322
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The work described herein assesses the ability to characterize gold nanoparticles (Au NPs) of 50 and 100 nm, as well as 60 nm silver shelled gold core nanospheres (Au/Ag NPs), for their mass, respective size, and isotopic composition in an automated and unattended fashion. Here, an innovative autosampler was employed to mix and transport the blanks, standards, and samples into a high-efficiency single particle (SP) introduction system for subsequent analysis by inductively coupled plasma-time of flight-mass spectrometry (ICP-TOF-MS). Optimized NP transport efficiency into the ICP-TOF-MS was determined to be >80%. This combination, SP-ICP-TOF-MS, allowed for high-throughput sample analysis. Specifically, 50 total samples (including blanks/standards) were analyzed over 8 h, to provide an accurate characterization of the NPs. This methodology was implemented over the course of 5 days to assess its long-term reproducibility. Impressively, the in-run and day-to-day variation of sample transport is assessed to be 3.54 and 9.52% relative standard deviation (%RSD), respectively. The determination of Au NP size and concentration was of <5% relative difference from the certified values over these time periods. Isotopic characterization of the Ag-107/Ag-109 particles (n = 132,630) over the course of the measurements was determined to be 1.0788 +/- 0.0030 with high accuracy (0.23% relative difference) when compared to the multi-collector-ICP-MS determination.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Isotopic analysis of Nd nanoparticles using single particle MC-ICP-MS: A comparative study with single particle-ICP-TOF-MS
    Manard, Benjamin T.
    Bradley, Veronica C.
    Hendriks, Lyndsey
    Dunlap, Daniel R.
    Zirakparvar, N. Alex
    Ticknor, Brian W.
    Toro-Gonzalez, Miguel
    Andrews, Hunter B.
    TALANTA, 2025, 286
  • [2] Arraying of Single Cells for Quantitative High Throughput Laser Ablation ICP-TOF-MS
    Loehr, Konrad
    Borovinskaya, Olga
    Tourniaire, Guilhem
    Panne, Ulrich
    Jakubowski, Norbert
    ANALYTICAL CHEMISTRY, 2019, 91 (18) : 11520 - 11528
  • [3] Non-target analysis and characterisation of nanoparticles in spirits via single particle ICP-TOF-MS
    de Vega, Raquel Gonzalez
    Lockwood, Thomas E.
    Paton, Lhiam
    Schlatt, Lukas
    Clases, David
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2023, 38 (12) : 2656 - 2663
  • [4] Facile separation, sizing, and quantitative analysis of engineered nanoparticles in an organism model using single particle ICP-MS
    Johnson, Monique
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2016, 251
  • [5] Quantifying platinum binding on protein-functionalized magnetic microparticles using single particle-ICP-TOF-MS
    Bradley, Veronica C.
    Manard, Benjamin T.
    Hendriks, Lyndsey
    Dunlap, Daniel R.
    Bible, Amber N.
    Sedova, Ada
    Saint-Vincent, Patricia
    Sanders, Brian C.
    Andrews, Hunter B.
    ANALYTICAL METHODS, 2024, 16 (20) : 3192 - 3201
  • [6] Automated High-Throughput Permethylation for Glycosylation Analysis of Biologics Using MALDI-TOF-MS
    Shubhakar, Archana
    Kozak, Radoslaw P.
    Reiding, Karli R.
    Royle, Louise
    Spencer, Daniel I. R.
    Fernandes, Daryl L.
    Wuhrer, Manfred
    ANALYTICAL CHEMISTRY, 2016, 88 (17) : 8562 - 8569
  • [7] High-Throughput/High-Precision Sampling of Single Cells into ICP-MS for Elucidating Cellular Nanoparticles
    Wei, Xing
    Zheng, Dong-Hua
    Cai, Yi
    Jiang, Rui
    Chen, Ming-Li
    Yang, Ting
    Xu, Zhang-Run
    Yu, Yong-Liang
    Wang, Jian-Hua
    ANALYTICAL CHEMISTRY, 2018, 90 (24) : 14543 - 14550
  • [8] Fully Automated, Intelligent, High-Throughput Elemental Analysis of Drinking Waters using SQ-ICP-MS
    Manecki, Marcus
    Kutscher, Daniel
    Wehe, Christoph
    Henry, Robert
    Wills, Julian
    Ducos, Shona McSheehy
    BRAZILIAN JOURNAL OF ANALYTICAL CHEMISTRY, 2018, 5 (19): : 65 - 69
  • [9] Fully Automated, Intelligent, High-Throughput Elemental Analysis of Drinking Waters using SQ-ICP-MS
    Manecki, Marcus
    Kutscher, Daniel
    Wehe, Christoph
    Henry, Robert
    Wills, Julian
    Ducos, Shona McSheehy
    BRAZILIAN JOURNAL OF ANALYTICAL CHEMISTRY, 2021, 8 (33): : 105 - 110
  • [10] High-Throughput Sizing, Counting, and Elemental Analysis of Anisotropic Multimetallic Nanoparticles with Single- Particle Inductively Coupled Plasma Mass Spectrometry
    Koolen, Cedric David
    Torrent, Laura
    Agarwal, Ayush
    Meili-Borovinskaya, Olga
    Gasilova, Natalia
    Li, Mo
    Luo, Wen
    Zuttel, Andreas
    ACS NANO, 2022, 16 (08) : 11968 - 11978