Technological advances in ventricular tachycardia catheter ablation: the relentless quest for novel solutions to old problems

被引:10
作者
Compagnucci, Paolo [1 ]
Valeri, Yari [1 ,2 ]
Conti, Sergio [3 ]
Volpato, Giovanni [1 ,2 ]
Cipolletta, Laura [1 ]
Parisi, Quintino [1 ]
D'Angelo, Leonardo [1 ,2 ]
Campanelli, Francesca [1 ,2 ]
Carboni, Laura [4 ]
Sgarito, Giuseppe [3 ]
Natale, Andrea [2 ,5 ,6 ,7 ]
Casella, Michela [1 ,8 ]
Dello Russo, Antonio [1 ,2 ]
机构
[1] Marche Univ Hosp, Cardiol & Arrhythmol Clin, Ancona, Italy
[2] Marche Polytech Univ, Dept Biomed Sci & Publ Hlth, Via Conca 71, I-60126 Ancona, Italy
[3] ARNAS Civ Di Cristina Benfratelli, Dept Cardiol, Electrophysiol Unit, Palermo, Italy
[4] Univ Hosp Ospedali Riuniti, Cardiac Surg Anesthesia & Crit Care Unit, Ancona, Italy
[5] Texas Cardiac Arrhythmia Inst, St Davids Med Ctr, Austin, TX USA
[6] Case Western Reserve Univ, Metro Hlth Med Ctr, Sch Med, Dept Internal Med, Cleveland Hts, OH USA
[7] Intervent Electrophysiol Scripps Clin, San Diego, CA USA
[8] Marche Polytech Univ, Dept Clin Special & Dent Sci, Ancona, Italy
关键词
Ventricular tachycardia; Catheter ablation; Pulsed field ablation; CENTAURI (TM); QDOT Micro (TM); TactiFlex (TM);
D O I
10.1007/s10840-023-01705-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BackgroundSeveral novel technologies allowing catheter ablation (CA) with a favorable safety/efficacy profile have been recently developed, but not yet extensively clinically tested in the setting of ventricular tachycardia CA.MethodsIn this technical report, we overview technical aspects and preclinical/clinical information concerning the application of three novel CA technologies in the ventricular milieu: a pulsed field ablation (PFA) generator (CENTAURI (TM), Galaxy Medical) to be used with linear, contact force-sensing radiofrequency ablation catheters; a contact force-sensing radiofrequency ablation catheter equipped with six thermocouples and three microelectrodes (QDOT Micro (TM), Biosense-Webster), allowing high-resolution mapping and temperature-controlled CA; and a flexible and mesh-shaped irrigation tip, contact force-sensing radiofrequency ablation catheter (Tactiflex, Abbott). We also report three challenging VT cases in which CA was performed using these technologies.ResultsThe CENTAURI system was used with the Tacticath (TM) (Abbott) ablation catheter to perform ventricular PFA in a patient with advanced heart failure, electrical storm, and a deep intramural septal substrate. Microelectrode mapping using QDOT Micro (TM) helped to refine substrate assessment in a VT patient with congenitally corrected transposition of the great arteries, and allowed the identification of the critical components of the VT circuit, which were successfully ablated. Tactiflex (TM) was used in two challenging CA cases (one endocardial and one epicardial), allowing acute and mid-term control of VT episodes without adverse events.ConclusionThe ideation and development of novel technologies initially intended to treat atrial arrhythmias and successfully implemented in the ventricular milieu is contributing to the progressive improvement in the clinical benefits derived from VT CA, making this procedure key for successful management of increasingly complex patients.
引用
收藏
页码:855 / 864
页数:10
相关论文
共 31 条
[1]   Implantable defibrillator-detected heart failure status predicts ventricular tachyarrhythmias [J].
Compagnucci, Paolo ;
Casella, Michela ;
Bianchi, Valter ;
Franculli, Fabio ;
Vitali, Francesco ;
Santini, Luca ;
Savarese, Gianluca ;
Santobuono, Vincenzo Ezio ;
Chianese, Raffaele ;
Lavalle, Carlo ;
Amellone, Claudia ;
Pecora, Domenico ;
Calvanese, Raimondo ;
Stronati, Giulia ;
Santoro, Amato ;
Ziacchi, Matteo ;
Campari, Monica ;
Valsecchi, Sergio ;
Calo, Leonardo ;
Guerra, Federico ;
Dello Russo, Antonio .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2023, 34 (05) :1257-1267
[2]   Ablation Index Predicts Successful Ablation of Focal Atrial Tachycardia: Results of a Multicenter Study [J].
Compagnucci, Paolo ;
Dello Russo, Antonio ;
Bergonti, Marco ;
Anselmino, Matteo ;
Zucchelli, Giulio ;
Gasperetti, Alessio ;
Cipolletta, Laura ;
Volpato, Giovanni ;
Ascione, Ciro ;
Ferraris, Federico ;
Valeri, Yari ;
Bongiorni, Maria Grazia ;
Natale, Andrea ;
Tondo, Claudio ;
De Ferrari, Gaetano Maria ;
Casella, Michela .
JOURNAL OF CLINICAL MEDICINE, 2022, 11 (07)
[3]   Recent advances in three-dimensional electroanatomical mapping guidance for the ablation of complex atrial and ventricular arrhythmias [J].
Compagnucci, Paolo ;
Volpato, Giovanni ;
Falanga, Umberto ;
Cipolletta, Laura ;
Conti, Manuel ;
Grifoni, Gino ;
Verticelli, Letizia ;
Schicchi, Nicolas ;
Giovagnoni, Andrea ;
Casella, Michela ;
Guerra, Federico ;
Dello Russo, Antonio .
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2021, 61 (01) :37-43
[4]  
Cronin EM, 2020, J INTERV CARD ELECTR, V59, P145, DOI 10.1007/s10840-019-00663-3
[5]   Stepwise endo-/epicardial catheter ablation for atrial fibrillation: The Mediterranea approach [J].
De Martino, Giuseppe ;
Compagnucci, Paolo ;
Mancusi, Carmine ;
Vassallo, Enrico ;
Calvanese, Claudia ;
Della Ratta, Giuseppe ;
Librera, Mariateresa ;
Franciulli, Marco ;
Marino, Luigi ;
Dello Russo, Antonio ;
Casella, Michela .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2021, 32 (08) :2107-2115
[6]   High-power short-duration catheter ablation of atrial fibrillation: is it really a new era? Comparison between new and old radiofrequency contact force-sensing catheters [J].
Dello Russo, Antonio ;
D'Angelo, Leonardo ;
Compagnucci, Paolo ;
Cipolletta, Laura ;
Parisi, Quintino ;
Valeri, Yari ;
Campanelli, Francesca ;
Volpato, Giovanni ;
Carboni, Laura ;
Ciliberti, Giuseppe ;
Stronati, Giulia Emily ;
Barbarossa, Alessandro ;
La Piscopia, Valentina ;
Bondavalli, Barbara ;
Guerra, Federico ;
Natale, Andrea ;
Casella, Michela .
JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2024, 67 (03) :549-557
[7]   Microelectrode voltage mapping for substrate assessment in catheter ablation of ventricular tachycardia: A dual-center experience [J].
Dello Russo, Antonio ;
Compagnucci, Paolo ;
Bergonti, Marco ;
Cipolletta, Laura ;
Parisi, Quintino ;
Volpato, Giovanni ;
Santarelli, Giulia ;
Colonnelli, Michela ;
Saenen, Johan ;
Valeri, Yari ;
Carboni, Laura ;
Marchese, Procolo ;
Marini, Marco ;
Sarkozy, Andrea ;
Natale, Andrea ;
Casella, Michela .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2023, 34 (05) :1216-1227
[8]   Utility of Prolonged Duration Endocardial Ablation for Ventricular Arrhythmias Originating From the Left Ventricular Summit [J].
Garg, Lohit ;
Daubert, Thomas ;
Lin, Aung ;
Dhakal, Bishnu ;
Santangeli, Pasquale ;
Schaller, Robert ;
Hyman, Matthew C. ;
Kumareswaran, Ramanan ;
Arkles, Jeffrey ;
Nazarian, Saman ;
Lin, David ;
Riley, Michael P. ;
Supple, Gregory E. ;
Frankel, David S. ;
Zado, Erica ;
Callans, David J. ;
Marchlinski, Francis E. ;
Dixit, Sanjay .
JACC-CLINICAL ELECTROPHYSIOLOGY, 2022, 8 (04) :465-476
[9]   Endocardial substrate of ventricular tachycardia in an adult patient with congenitally corrected transposition of great arteries without surgical repair [J].
Gonzalez-Lozano, Jaime ;
Ballesteros, Gabriel ;
Cano, Joaquin ;
Osorio, Diego ;
Urbano, Cristobal .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2024, 47 (03) :440-444
[10]   Ventricular Tachycardia Ablation Past, Present, and Future Perspectives [J].
Guandalini, Gustavo S. ;
Liang, Jackson J. ;
Marchlinski, Francis E. .
JACC-CLINICAL ELECTROPHYSIOLOGY, 2019, 5 (12) :1363-1383