Comparison between stereophotogrammetric, digital, and conventional impression techniques in implant-supported fixed complete arch prostheses: An in vitro study

被引:37
作者
Tohme, Hani [1 ,4 ]
Lawand, Ghida [2 ]
Chmielewska, Maja [3 ]
Makhzoume, Joseph [1 ]
机构
[1] St Joseph Univ, Fac Dent Med, Dept Removable Prosthodont, Beirut, Lebanon
[2] St Joseph Univ, Fac Dent Med, Dept Prosthodont & Esthet Dent, Beirut, Lebanon
[3] Private practice, Gdansk, Poland
[4] St Joseph Univ, Dept Removable Prosthodont, Damascus St,BP 11-5076,Riad Solh, Beirut 11072180, Lebanon
关键词
MULTIPLE IMPLANTS; INTRAORAL SCANNER; EDENTULOUS PATIENTS; ACCURACY; PHOTOGRAMMETRY; PRECISION; TRUENESS; CASTS; TECHNOLOGY; STRATEGIES;
D O I
10.1016/j.prosdent.2021.05.006
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Conventional impressions and digital intraoral scanning for implant-supported fixed complete arch prostheses still have many problems that influence accuracy. Although stereophotogrammetry may offer a reliable alternative to other techniques, it has seldom been investigated.Purpose. The purpose of this in vitro study was to measure and compare the intraoral scan body deviations of the reference cast with the intraoral scan body distortions obtained by conventional, digital, and stereophotogrammetric techniques.Materials and methods. An edentulous maxillary "all-on-four " cast was prepared with 2 straight and two 17-degree angled screw-retained abutments screwed on the implant. Three capture techniques were compared: the conventional impression technique (CI group) using impression plaster (IP), the digital intraoral scanning (DIS group) technique, and the stereophotogrammetry (SPG group) technique. A calibrated extraoral scanner was used to digitize the definitive cast to compare its intraoral scan body positions with those of the other techniques in terms of global angular distortion and 3D deviations of the whole scan body and flat angled surface alone by using an inspection and metrology software program and the best fit alignment technique. The Kolmogorov-Smirnov and Shapiro-Wilk tests showed normal distribution of the quantitative variables. Thus, the repeated measures analyses of variance followed by univariate analysis and Bonferroni multiple comparison tests were performed to analyze the data (a=.05).Results. Significant global angular discrepancies and 3D deviations of the whole scan body and flat angled surface were found among the CI, DI, and SPG groups for both trueness (P <.001) and precision (P <.001).Conclusions. The stereophotogrammetry capture technique reported the highest accuracy in terms of trueness and precision for the intraoral scan bodies of all the techniques evaluated. However, at the flat angled surface region of the scan body, higher trueness was detected with the digital technique. Conventional impressions showed better trueness results than the digital ones, but the opposite was true of precision.
引用
收藏
页码:354 / 362
页数:9
相关论文
共 50 条
  • [41] In Vivo Complete-Arch Implant Digital Impressions: Comparison of the Precision of Three Optical Impression Systems
    Orejas-Perez, Jaime
    Gimenez-Gonzalez, Beatriz
    Ortiz-Collado, Ignacio
    Thuissard, Israel J.
    Santamaria-Laorden, Andrea
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2022, 19 (07)
  • [42] Knowledge structure and research hotspots on digital scanning for implant-supported complete-arch prosthesis: A bibliometric analysis
    Gao, Yutong
    Zhao, Mingyu
    Xia, Shici
    Sa, Yue
    HELIYON, 2024, 10 (17)
  • [43] Comparison of Intraoral Scanning Modes in Three Distinct Full-Arch Digital Implant Impression Scenarios: An In Vitro Study
    Sezer, Taygun
    Yilmaz, Erkan
    Esim, Emir
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2024, 39 (06) : e217 - e222
  • [44] Clinical evaluation of full-arch screw-retained implant-supported fixed prostheses and full-arch telescopic-retained implant-supported fixed prostheses: A 5-12 year follow-up retrospective study
    Mori, Gentaro
    Oda, Yukari
    Sakamoto, Kei
    Ito, Taichi
    Yajima, Yasutomo
    CLINICAL ORAL IMPLANTS RESEARCH, 2019, 30 (03) : 197 - 205
  • [45] Improved scanning accuracy with newly designed scan bodies: An in vitro study comparing digital versus conventional impression techniques for complete-arch implant rehabilitation
    Huang, Ruoxuan
    Liu, Yuanxiang
    Huang, Baoxin
    Zhang, Chaobiao
    Chen, Zhuofan
    Li, Zhipeng
    CLINICAL ORAL IMPLANTS RESEARCH, 2020, 31 (07) : 625 - 633
  • [46] A completely digital approach to replicating functional and esthetic parameters in mandibular implant-supported complete-arch prostheses
    de Almeida, Daniel Costa Ferreira
    Calasans-Maia, Monica Diuana
    Zimmermann, Diego
    Moraschini, Vittorio
    JOURNAL OF PROSTHETIC DENTISTRY, 2021, 126 (05) : 622 - 625
  • [47] Complications of Fixed Full-Arch Implant-Supported Metal-Ceramic Prostheses
    Gonzalez-Gonzalez, Ignacio
    deLlanos-Lanchares, Hector
    Brizuela-Velasco, Aritza
    Alvarez-Riesgo, Jose-Antonio
    Llorente-Pendas, Santiago
    Herrero-Climent, Mariano
    Alvarez-Arenal, Angel
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2020, 17 (12) : 1 - 23
  • [48] Clinician preferences for complete-arch fixed implant-supported prostheses: A survey of the membership of the Pacific Coast Society for Prosthodontics
    Schoenbaum, Todd R.
    Guichet, David L.
    Jang, Jae Y.
    Kim, Young K.
    Wadhwani, Chandur P. K.
    JOURNAL OF PROSTHETIC DENTISTRY, 2020, 124 (06) : 699 - 705
  • [49] Obtaining reliable intraoral digital scans for an implant-supported complete-arch prosthesis: A dental technique
    Iturrate, Mikel
    Minguez, Rikardo
    Pradies, Guillermo
    Solaberrieta, Eneko
    JOURNAL OF PROSTHETIC DENTISTRY, 2019, 121 (02) : 237 - 241
  • [50] Accuracy of Implant Level Intraoral Scanning and Photogrammetry Impression Techniques in a Complete Arch with Angled and Parallel Implants: An In Vitro Study
    Tohme, Hani
    Lawand, Ghida
    Eid, Rita
    Ahmed, Khaled E.
    Salameh, Ziad
    Makzoume, Joseph
    APPLIED SCIENCES-BASEL, 2021, 11 (21):