Sharing calibration information among laser-induced breakdown spectroscopy instruments using spectral line binning and calibration transfer

被引:4
作者
Lepore, K. H. [1 ]
Dyar, M. D. [1 ,2 ]
Ytsma, C. R. [3 ,4 ]
机构
[1] Mt Holyoke Coll, Dept Astron, 50 Coll St, South Hadley, MA 01075 USA
[2] Planetary Sci Inst, 1700 E Ft Lowell Rd Suite 106, Tucson, AZ 85719 USA
[3] UCL, London WC1E 6BT, England
[4] Cai Consulting, Cottingham, England
基金
美国国家航空航天局;
关键词
LIBS; Multivariate analysis; Spectral resolution; Calibration transfer; CHEMCAM INSTRUMENT; GALE CRATER; OBJECTIVES; UNIVARIATE; PREDICTION; ACCURACY; SUITE; ROCKS; UNIT; SOIL;
D O I
10.1016/j.sab.2023.106839
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
The ability of a publicly accessible preexisting laser-induced breakdown spectroscopy (LIBS) database to train multivariate models to predict rock and mineral compositions from other laboratories or from remotely collected spectra is evaluated using LIBS spectra collected on >2500 unique geological targets using three different instruments and a range of collection protocols. Datasets collected under increasingly disparate conditions are utilized, including a single instrument with different resolution settings; two different instruments with very similar ablation and collection optics; and a benchtop instrument and portable instrument with different collection protocols, resolutions, and plasma conditions. Cross-calibration among datasets is performed for a range of scenarios designed to test the efficacy of post-processing techniques. Major element predictions are most accurate when instrument parameters match among training and test spectra. Use of a piecewise direct standardization-partial least squares (PDS-PLS) calibration transfer algorithm reduces major element prediction uncertainties when the resolution of training and test spectra do not match. Even when training and test spectra are collected on different instruments, reasonable predictions can be derived by binning peak areas prior to training calibration models. Finally, incorporating a large, preexisting database into a smaller dataset collected under test conditions has the potential to greatly improve the reliability of predicted compositions. With careful consideration to match plasma conditions and utilize post-processing, existing large-scale LIBS calibration databases like the one used in this study can be used to boost LIBS accuracy and expand the potential of LIBS as a widely-applicable quantitative geochemical tool.
引用
收藏
页数:12
相关论文
共 59 条
[1]   Characterization of LIBS emission lines for the identification of chlorides, carbonates, and sulfates in salt/basalt mixtures for the application to MSL ChemCam data [J].
Anderson, D. E. ;
Ehlmann, B. L. ;
Forni, O. ;
Clegg, S. M. ;
Cousin, A. ;
Thomas, N. H. ;
Lasue, J. ;
Delapp, D. M. ;
McInroy, R. E. ;
Gasnault, O. ;
Dyar, M. D. ;
Schroeder, S. ;
Maurice, S. ;
Wiens, R. C. .
JOURNAL OF GEOPHYSICAL RESEARCH-PLANETS, 2017, 122 (04) :744-770
[2]  
Anderson D.E., 2015, Lunar Planet. Sci. XLVI
[3]   Post-landing major element quantification using SuperCam laser induced breakdown spectroscopy [J].
Anderson, Ryan B. ;
Forni, Olivier ;
Cousin, Agnes ;
Wiens, Roger C. ;
Clegg, Samuel M. ;
Frydenvang, Jens ;
Gabriel, Travis S. J. ;
Ollila, Ann ;
Schroder, Susanne ;
Beyssac, Olivier ;
Gibbons, Erin ;
Vogt, David S. ;
Clave, Elise ;
Manrique, Jose-Antonio ;
Legett, Carey ;
Pilleri, Paolo ;
Newell, Raymond T. ;
Sarrao, Joseph ;
Maurice, Sylvestre ;
Arana, Gorka ;
Benzerara, Karim ;
Bernardi, Pernelle ;
Bernard, Sylvain ;
Bousquet, Bruno ;
Brown, Adrian J. ;
Alvarez-Llamas, Cesar ;
Chide, Baptiste ;
Cloutis, Edward ;
Comellas, Jade ;
Connell, Stephanie ;
Dehouck, Erwin ;
Delapp, Dorothea M. ;
Essunfeld, Ari ;
Fabre, Cecile ;
Fouchet, Thierry ;
Garcia-Florentino, Cristina ;
Garcia-Gomez, Laura ;
Gasda, Patrick ;
Gasnault, Olivier ;
Hausrath, Elisabeth M. ;
Lanza, Nina L. ;
Laserna, Javier ;
Lasue, Jeremie ;
Lopez, Guillermo ;
Manuel Madariaga, Juan ;
Mandon, Lucia ;
Mangold, Nicolas ;
Meslin, Pierre-Yves ;
Nelson, Anthony E. ;
Newsom, Horton .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2022, 188
[4]   Improved accuracy in quantitative laser-induced breakdown spectroscopy using sub-models [J].
Anderson, Ryan B. ;
Clegg, Samuel M. ;
Frydenvang, Jens ;
Wiens, Roger C. ;
McLennan, Scott ;
Morris, Richard V. ;
Ehlmann, Bethany ;
Dyar, M. Darby .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2017, 129 :49-57
[5]   The influence of multivariate analysis methods and target grain size on the accuracy of remote quantitative chemical analysis of rocks using laser induced breakdown spectroscopy [J].
Anderson, Ryan B. ;
Morris, Richard V. ;
Clegg, Samuel M. ;
Bell, James F., III ;
Wiens, Roger C. ;
Humphries, Seth D. ;
Mertzman, Stanley A. ;
Graff, Trevor G. ;
McInroy, Rhonda .
ICARUS, 2011, 215 (02) :608-627
[6]  
Blank J.G., 2015, Lunar Planet. Sci. XLVI
[7]   Proximal methods for calibration transfer [J].
Boucher, Thomas ;
Dyar, M. Darby ;
Mahadevan, Sridhar .
JOURNAL OF CHEMOMETRICS, 2017, 31 (04)
[8]   A study of machine learning regression methods for major elemental analysis of rocks using laser-induced breakdown spectroscopy [J].
Boucher, Thomas F. ;
Ozanne, Marie V. ;
Carmosino, Marco L. ;
Dyar, M. Darby ;
Mahadevan, Sridhar ;
Breves, Elly A. ;
Lepore, Kate H. ;
Clegg, Samuel M. .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2015, 107 :1-10
[9]   Convolutional neural network as a novel classification approach for laser-induced breakdown spectroscopy applications in lithological recognition [J].
Chen, Junxi ;
Pisonero, Jorge ;
Chen, Sha ;
Wang, Xu ;
Fan, Qingwen ;
Duan, Yixiang .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2020, 166
[10]   Probabilistic multivariable calibration for major elements analysis of MarSCoDe Martian laser-induced breakdown spectroscopy instrument on Zhurong rover [J].
Chen, Zhaopeng ;
Ren, Xin ;
Liu, Jianjun ;
Xu, Weiming ;
Zhang, Yizhong ;
Liu, Xiangfeng ;
Zhou, Qin ;
Chen, Wangli .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2022, 197