Flow and mass transfer prediction in anisotropic TPMS-structures as extracorporeal oxygenator membranes using reduced order modeling

被引:7
作者
Barbian, Kai P. [1 ]
Hirschwald, Lukas T. [2 ]
Linkhorst, John [2 ,3 ]
Neidlin, Michael [1 ]
Steinseifer, Ulrich [1 ]
Wessling, Matthias [2 ,3 ]
Wiegmann, Bettina [4 ,5 ,6 ]
Jansen, Sebastian, V [1 ]
机构
[1] Rhein Westfal TH Aachen, Inst Appl Med Engn, Dept Cardiovasc Engn, Forckenbeckstr 55, D-52074 Aachen, Germany
[2] Rhein Westfal TH Aachen, Chem Proc Engn, Forckenbeckstr 51, D-52074 Aachen, Germany
[3] DWI Leibniz Inst Interact Mat, Forckenbeckstr 50, D-52074 Aachen, Germany
[4] Hannover Med Sch, Dept Cardiothorac Transplantat & Vasc Surg, Carl Neuberg Str 1, D-30625 Hannover, Germany
[5] Implant Res & Dev NIFE, Lower Saxony Ctr Biomed Engn, Stadtfelddamm 34, D-30625 Hannover, Germany
[6] German Ctr Lung Res DZL, Carl Neuberg Str 1, D-30625 Hannover, Germany
关键词
Membrane oxygenator; TPMS; Reduced order modeling; Gas transfer simulation; Anisotropic; MATHEMATICAL-MODEL; GAS-EXCHANGE; PERMEABILITY; DIFFUSION; TRANSPORT; CFD; PERFORMANCE; NETWORK; PDMS;
D O I
10.1016/j.memsci.2023.122160
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Currently, hollow fiber membranes are the standard technology for extracorporeal membrane oxygenators. Apart from the inevitable contact of the circulating blood with the artificial material, a suboptimal flow distribution within the oxygenator favors thrombus formation which leads to a rapid loss of gas exchange capacity. The current advancement in additive manufacturing allows the design of three-dimensional membrane structures, based on triply periodic minimal surfaces (TPMS). One of their unique advantages is local geometry variation to manipulate the flow distribution. But how this anisotropy influences the overall device performance is non-trivial and requires numerical simulation. The aim of this study was to develop a reduced order model (ROM) that is able to efficiently predict three-dimensional flow distribution and gas transfer inside TPMSstructures. We performed a parametric study using a validated micro scale computational fluid dynamics (CFD) model. Afterwards, two different modeling approaches of Sherwood-correlations and artificial neural networks (NN) were compared to characterize flow and mass transfer from the simulated data. To create the ROM, the NN modeling strategy was then implemented into a porous medium CFD model. The developed ROM was also validated. Finally, an anisotropic TPMS-membrane-structure was compared numerically with an isotropic predicate. The NN fitting strategy showed superior accuracy over the Sherwood-correlations for characterizing mass transfer in TPMS-structures. With the ROM, the gas transfer rates of oxygen and carbon dioxide from the micro CFD model could be predicted within relative root mean squared errors (RRMSE) of 2.7% and 5.1%. The pressure drop in the experiments was predicted with an RRMSE accuracy of 7.6%. In comparison with the isotropic TPMS-structure, the anisotropic structure showed a homogenized flow distribution and increased gas transfer rates of 4% to 5% for oxygen and 2.3% to 7.4% for carbon dioxide at the simulated flow rates.
引用
收藏
页数:13
相关论文
共 62 条
[51]   Numerical washout study of a pulsatile total artificial heart [J].
Sonntag, Simon J. ;
Kaufmann, Tim A. S. ;
Buesen, Martin R. ;
Laumen, Marco ;
Graef, Felix ;
Linde, Torsten ;
Steinseifer, Ulrich .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2014, 37 (03) :241-252
[52]   A mathematical model to predict CO2 removal in hollow fiber membrane oxygenators [J].
Svitek, R. G. ;
Federspiel, W. J. .
ANNALS OF BIOMEDICAL ENGINEERING, 2008, 36 (06) :992-1003
[53]   Analysis on the convective heat transfer process and performance evaluation of Triply Periodic Minimal Surface (TPMS) based on Diamond, Gyroid and Iwp [J].
Tang, Wei ;
Zhou, Hua ;
Zeng, Yun ;
Yan, Minglei ;
Jiang, Chenglu ;
Yang, Ping ;
Li, Qing ;
Li, Zhida ;
Fu, Junheng ;
Huang, Yi ;
Zhao, Yang .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2023, 201
[54]   Micro-scale modeling of flow and oxygen transfer in hollow-fiber membrane bundle [J].
Taskin, M. Ertan ;
Fraser, Katharine H. ;
Zhang, Tao ;
Griffith, Bartley P. ;
Wu, Zhongjun J. .
JOURNAL OF MEMBRANE SCIENCE, 2010, 362 (1-2) :172-183
[55]   Polymeric hollow fiber membrane oxygenators as artificial lungs: A review [J].
Teber, Oguz Orhun ;
Altinay, Aysegul Derya ;
Mehrabani, Seyed Ali Naziri ;
Tasdemir, Reyhan Sengur ;
Zeytuncu, Bihter ;
Genceli, Esra Ates ;
Dulekgurgen, Ebru ;
Pekkan, Kerem ;
Koyuncu, Ismail .
BIOCHEMICAL ENGINEERING JOURNAL, 2022, 180
[56]  
VDI-Warmeatlas: Mit 320 Tabellen, 2013, VDI-Buch, V11
[57]   FLOW IN POROUS-MEDIA .1. A THEORETICAL DERIVATION OF DARCYS-LAW [J].
WHITAKER, S .
TRANSPORT IN POROUS MEDIA, 1986, 1 (01) :3-25
[58]  
White F.M, 2003, Mcgraw-Hill Series in Mechanical Engineering
[59]  
[吴桐 Wu Tong], 2022, [系统仿真学报, Journal of System Simulation], V34, P1015
[60]   Extracorporeal membrane oxygenation and V/Q ratios: an ex vivo analysis of CO2 clearance within the Maquet Quadrox-iD oxygenator [J].
Zakhary, Bishoy ;
Sheldrake, Jayne ;
Pellegrino, Vincent .
PERFUSION-UK, 2020, 35 :29-33