Flow and mass transfer prediction in anisotropic TPMS-structures as extracorporeal oxygenator membranes using reduced order modeling

被引:7
作者
Barbian, Kai P. [1 ]
Hirschwald, Lukas T. [2 ]
Linkhorst, John [2 ,3 ]
Neidlin, Michael [1 ]
Steinseifer, Ulrich [1 ]
Wessling, Matthias [2 ,3 ]
Wiegmann, Bettina [4 ,5 ,6 ]
Jansen, Sebastian, V [1 ]
机构
[1] Rhein Westfal TH Aachen, Inst Appl Med Engn, Dept Cardiovasc Engn, Forckenbeckstr 55, D-52074 Aachen, Germany
[2] Rhein Westfal TH Aachen, Chem Proc Engn, Forckenbeckstr 51, D-52074 Aachen, Germany
[3] DWI Leibniz Inst Interact Mat, Forckenbeckstr 50, D-52074 Aachen, Germany
[4] Hannover Med Sch, Dept Cardiothorac Transplantat & Vasc Surg, Carl Neuberg Str 1, D-30625 Hannover, Germany
[5] Implant Res & Dev NIFE, Lower Saxony Ctr Biomed Engn, Stadtfelddamm 34, D-30625 Hannover, Germany
[6] German Ctr Lung Res DZL, Carl Neuberg Str 1, D-30625 Hannover, Germany
关键词
Membrane oxygenator; TPMS; Reduced order modeling; Gas transfer simulation; Anisotropic; MATHEMATICAL-MODEL; GAS-EXCHANGE; PERMEABILITY; DIFFUSION; TRANSPORT; CFD; PERFORMANCE; NETWORK; PDMS;
D O I
10.1016/j.memsci.2023.122160
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Currently, hollow fiber membranes are the standard technology for extracorporeal membrane oxygenators. Apart from the inevitable contact of the circulating blood with the artificial material, a suboptimal flow distribution within the oxygenator favors thrombus formation which leads to a rapid loss of gas exchange capacity. The current advancement in additive manufacturing allows the design of three-dimensional membrane structures, based on triply periodic minimal surfaces (TPMS). One of their unique advantages is local geometry variation to manipulate the flow distribution. But how this anisotropy influences the overall device performance is non-trivial and requires numerical simulation. The aim of this study was to develop a reduced order model (ROM) that is able to efficiently predict three-dimensional flow distribution and gas transfer inside TPMSstructures. We performed a parametric study using a validated micro scale computational fluid dynamics (CFD) model. Afterwards, two different modeling approaches of Sherwood-correlations and artificial neural networks (NN) were compared to characterize flow and mass transfer from the simulated data. To create the ROM, the NN modeling strategy was then implemented into a porous medium CFD model. The developed ROM was also validated. Finally, an anisotropic TPMS-membrane-structure was compared numerically with an isotropic predicate. The NN fitting strategy showed superior accuracy over the Sherwood-correlations for characterizing mass transfer in TPMS-structures. With the ROM, the gas transfer rates of oxygen and carbon dioxide from the micro CFD model could be predicted within relative root mean squared errors (RRMSE) of 2.7% and 5.1%. The pressure drop in the experiments was predicted with an RRMSE accuracy of 7.6%. In comparison with the isotropic TPMS-structure, the anisotropic structure showed a homogenized flow distribution and increased gas transfer rates of 4% to 5% for oxygen and 2.3% to 7.4% for carbon dioxide at the simulated flow rates.
引用
收藏
页数:13
相关论文
共 62 条
[1]   Biohybrid lung Development: Towards Complete Endothelialization of an Assembled Extracorporeal Membrane Oxygenator [J].
Alabdullh, Hussam Almesto ;
Pflaum, Michael ;
Maelzer, Marisa ;
Kipp, Marcel ;
Naghilouy-Hidaji, Hossein ;
Adam, Denise ;
Kuehn, Christian ;
Natanov, Russlan ;
Niehaus, Adelheid ;
Haverich, Axel ;
Wiegmann, Bettina .
BIOENGINEERING-BASEL, 2023, 10 (01)
[2]   Permeability and fluid flow-induced wall shear stress in bone scaffolds with TPMS and lattice architectures: A CFD analysis [J].
Ali, Davar ;
Ozalp, Mehmet ;
Blanquer, Sebastien B. G. ;
Onel, Selis .
EUROPEAN JOURNAL OF MECHANICS B-FLUIDS, 2020, 79 :376-385
[3]  
[Anonymous], 1995, Science of advanced materials and process engineering series, V40
[4]   Analytical model for the prediction of permeability of triply periodic minimal surfaces [J].
Asbai-Ghoudan, Reduan ;
Ruiz de Galarreta, Sergio ;
Rodriguez-Florez, Naiara .
JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2021, 124
[5]  
Barth T.J., 1989, DESIGN APPL UPWIND S, DOI DOI 10.2514/6.1989-366
[6]  
Bergman T.L., 2011, FUNDAMENTALS HEAT MA, V7th
[7]   Analysis of Thrombotic Deposits in Extracorporeal Membrane Oxygenators by High-resolution Microcomputed Tomography: A Feasibility Study [J].
Birkenmaier, Clemens ;
Dornia, Christian ;
Lehle, Karla ;
Mueller, Thomas ;
Gruber, Michael ;
Philipp, Alois ;
Krenkel, Lars .
ASAIO JOURNAL, 2020, 66 (08) :922-928
[8]   An Accelerated Thrombosis Model for Computational Fluid Dynamics Simulations in Rotary Blood Pumps [J].
Blum, Christopher ;
Gross-Hardt, Sascha ;
Steinseifer, Ulrich ;
Neidlin, Michael .
CARDIOVASCULAR ENGINEERING AND TECHNOLOGY, 2022, 13 (4) :638-649
[9]   Analysis of the Casson and Carreau-Yasuda non-Newtonian blood models in steady and oscillatory flows using the lattice Boltzmann method [J].
Boyd, Joshua ;
Buick, James M. ;
Green, Simon .
PHYSICS OF FLUIDS, 2007, 19 (09)
[10]  
Brodie D., 2022, Extracorporeal life support: the ELSO red book. 6th ed