Integration of Centralized and Distributed Methods to Mitigate Voltage Unbalance Using Solar Inverters

被引:8
作者
Girigoudar, Kshitij [1 ]
Yao, Mengqi [2 ]
Mathieu, Johanna L. L. [2 ]
Roald, Line A. A. [1 ]
机构
[1] Univ Wisconsin, Dept Elect & Comp Engn, Madison, WI 53715 USA
[2] Univ Michigan, Dept Elect Engn & Comp Sci, Ann Arbor, MI 48103 USA
关键词
Voltage control; Reactive power; Inverters; Voltage measurement; Power measurement; Load modeling; Loss measurement; Reactive power compensation; solar PV; Steinmetz design; three-phase optimal power flow; voltage unbalance; REACTIVE POWER-CONTROL; DISTRIBUTION NETWORK; DISTRIBUTION-SYSTEMS; ENERGY-STORAGE; REDUCTION; DESIGN;
D O I
10.1109/TSG.2022.3214192
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Growing penetrations of single-phase distributed generation such as rooftop solar photovoltaic (PV) systems can increase voltage unbalance in distribution grids. However, PV systems are also capable of providing reactive power compensation to reduce unbalance. In this paper, we compare two methods to mitigate voltage unbalance with solar PV inverters: a centralized optimization-based method utilizing a three-phase optimal power flow formulation and a distributed approach based on Steinmetz design. While the Steinmetz-based method is computationally simple and does not require extensive communication or full network data, it generally leads to less unbalance improvement and more voltage constraint violations than the optimization-based method. In order to improve the performance of the Steinmetz-based method without adding the full complexity of the optimization-based method, we propose an integrated method that incorporates design parameters computed from the set-points generated by the optimization-based method into the Steinmetz-based method. We test and compare all methods on a large three-phase distribution feeder with time-varying load and PV data. The simulation results indicate trade-offs between the methods in terms of computation time, voltage unbalance reduction, and constraint violations. We find that the integrated method can provide a good balance between performance and information/communication requirements.
引用
收藏
页码:2034 / 2046
页数:13
相关论文
共 41 条
[1]  
[Anonymous], 2022, OP MOD FRAM
[2]  
[Anonymous], 2019, DATAPORT WORLDS LARG
[3]  
[Anonymous], 2022, GRIDLAB D TAX FEED
[4]  
[Anonymous], 2022, MEASUREMENT INSTRUME
[5]  
Bajo CG, 2015, 2015 IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL TECHNOLOGY (ICIT), P2875, DOI 10.1109/ICIT.2015.7125522
[6]   Comprehensive Modeling of Three-Phase Distribution Systems via the Bus Admittance Matrix [J].
Bazrafshan, Mohammadhafez ;
Gatsis, Nikolaos .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2018, 33 (02) :2015-2029
[7]  
Electromagnetic Compatibility (EMC), 2018, 6100022 IEC, V2
[8]  
Fonescue C. L., 1918, Proc. Am. Inst. Electr. Eng., V37, P629
[9]   Convergence of Distributed Steinmetz Control for Balancing Distribution Network Voltages [J].
Geng, Sijia ;
Hiskens, Ian A. .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2022, 37 (05) :3370-3380
[10]   Linearized Three-Phase Optimal Power Flow Models for Distribution Grids with Voltage Unbalance [J].
Girigoudar, Kshitij ;
Roald, Line A. .
2021 60TH IEEE CONFERENCE ON DECISION AND CONTROL (CDC), 2021, :4214-4221