Human Fatty Liver Volume Measurement Device Using Nano Graphene Polyvinyl Sensor

被引:0
作者
Srilekha, M. K. [1 ]
Deepa, S. N. [2 ]
Shanker, N. R. [3 ]
Priya, M. [4 ]
机构
[1] SRM Inst Sci & Technol, Dept Elect & Commun Engn, Coll Engn & Technol, Chennai 603203, Tamil Nadu, India
[2] Natl Inst Technol Calicut, Dept Elect Engn, Kozhikode 673601, India
[3] Anna Univ, Aalim Muhammed Salegh Coll Engn, Chennai 600055, India
[4] Anna Univ, Saveetha Engn Coll, Chennai 602105, India
关键词
Liver; Ultrasonic imaging; Sensors; Volume measurement; Monitoring; Liver diseases; Ultrasonic variables measurement; Fatty liver (FL); human FL (HFL); multisynchrosqueezing transform (MSST); nano graphene polyvinyl (NGP); nonalcoholic FL diseases (NAFLDs); ultrasound (US); EPIDERMAL ELECTRONICS; HEPATIC STEATOSIS; DISEASE; ASSOCIATION; TOMOGRAPHY; DIAGNOSIS;
D O I
10.1109/JSEN.2023.3308769
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this article, human fatty liver (HFL) volume is measured using the proposed HFL device. The HFL device consists of nano graphene polyvinyl (NGP) sensor and node microcontroller (MCU). The NGP sensor acquires electromagnetic radiations from fatty liver (FL), which arise due to dielectric materials in fat. Continuous monitoring of FL volume through various medical imaging instruments leads to frequent exposure of radiation. The HFL device is used for monitoring the FL diseases like other continuous monitoring devices such as diabetes, hemoglobin, and blood pressure for effective diagnosis and treatment of liver diseases. In the HFL device, the NGP sensor is fabricated using the spray pyrolysis method. The NGP sensor consists of different materials such as nano graphene, poly acrylic acid, methylenbisacrylamide (MBAAm), and 2,2-dimethoxy-2-phenyl acetophenone (DMPAP) poly vinyl acetate. The NGP sensor is fixed on the human liver surface and acquires scattering dielectric radiation from liver. The acquired signal is processed with nonnegative matrix filter blind source separation for removal of random motion noise and extracts the FL signals. From the filtered FL signal, instantaneous frequency is obtained through multisynchrosqueezing transform (MSST). Furthermore, FL volume is measured through instantaneous frequency and Gaussian Regression model. The HFL device-based FL volume measurement is validated through FL ultrasound (US) image-based volume measurement and provides an accuracy of about 85%.
引用
收藏
页码:25390 / 25400
页数:11
相关论文
共 21 条
  • [21] Applicability and Results of Liver Stiffness Measurement and Controlled Attenuation Parameter Using XL Probe for Metabolic-Associated Fatty Liver Disease in Candidates to Bariatric Surgery. A Single-Center Observational Study
    Wan, Tao
    Koehn, Nastassja
    Kroell, Dino
    Berzigotti, Annalisa
    OBESITY SURGERY, 2021, 31 (02) : 702 - 711