Human Fatty Liver Volume Measurement Device Using Nano Graphene Polyvinyl Sensor

被引:0
作者
Srilekha, M. K. [1 ]
Deepa, S. N. [2 ]
Shanker, N. R. [3 ]
Priya, M. [4 ]
机构
[1] SRM Inst Sci & Technol, Dept Elect & Commun Engn, Coll Engn & Technol, Chennai 603203, Tamil Nadu, India
[2] Natl Inst Technol Calicut, Dept Elect Engn, Kozhikode 673601, India
[3] Anna Univ, Aalim Muhammed Salegh Coll Engn, Chennai 600055, India
[4] Anna Univ, Saveetha Engn Coll, Chennai 602105, India
关键词
Liver; Ultrasonic imaging; Sensors; Volume measurement; Monitoring; Liver diseases; Ultrasonic variables measurement; Fatty liver (FL); human FL (HFL); multisynchrosqueezing transform (MSST); nano graphene polyvinyl (NGP); nonalcoholic FL diseases (NAFLDs); ultrasound (US); EPIDERMAL ELECTRONICS; HEPATIC STEATOSIS; DISEASE; ASSOCIATION; TOMOGRAPHY; DIAGNOSIS;
D O I
10.1109/JSEN.2023.3308769
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this article, human fatty liver (HFL) volume is measured using the proposed HFL device. The HFL device consists of nano graphene polyvinyl (NGP) sensor and node microcontroller (MCU). The NGP sensor acquires electromagnetic radiations from fatty liver (FL), which arise due to dielectric materials in fat. Continuous monitoring of FL volume through various medical imaging instruments leads to frequent exposure of radiation. The HFL device is used for monitoring the FL diseases like other continuous monitoring devices such as diabetes, hemoglobin, and blood pressure for effective diagnosis and treatment of liver diseases. In the HFL device, the NGP sensor is fabricated using the spray pyrolysis method. The NGP sensor consists of different materials such as nano graphene, poly acrylic acid, methylenbisacrylamide (MBAAm), and 2,2-dimethoxy-2-phenyl acetophenone (DMPAP) poly vinyl acetate. The NGP sensor is fixed on the human liver surface and acquires scattering dielectric radiation from liver. The acquired signal is processed with nonnegative matrix filter blind source separation for removal of random motion noise and extracts the FL signals. From the filtered FL signal, instantaneous frequency is obtained through multisynchrosqueezing transform (MSST). Furthermore, FL volume is measured through instantaneous frequency and Gaussian Regression model. The HFL device-based FL volume measurement is validated through FL ultrasound (US) image-based volume measurement and provides an accuracy of about 85%.
引用
收藏
页码:25390 / 25400
页数:11
相关论文
共 21 条
  • [1] Human Fatty Liver Monitoring Using Nano Sensor and IoMT
    Muthukaruppankaruppiah, Srilekha
    Nagalingam, Shanker Rajendiran
    Murugasen, Priya
    Nandaamarnath, Rajesh
    INTELLIGENT AUTOMATION AND SOFT COMPUTING, 2023, 35 (02) : 2309 - 2323
  • [2] Liver Stiffness Measurement Using XL Probe in Patients With Nonalcoholic Fatty Liver Disease
    Wong, Vincent Wai-Sun
    Vergniol, Julien
    Wong, Grace Lai-Hung
    Foucher, Juliette
    Chan, Anthony Wing-Hung
    Chermak, Faiza
    Choi, Paul Cheung-Lung
    Merrouche, Wassil
    Chu, Shirley Ho-Ting
    Pesque, Sophie
    Chan, Henry Lik-Yuen
    de Ledinghen, Victor
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2012, 107 (12) : 1862 - 1871
  • [3] ATTENUATION COEFFICIENT MEASUREMENT USING A HIGH-FREQUENCY (2-9 MHZ) CONVEX TRANSDUCER FOR CHILDREN INCLUDING FATTY LIVER
    Yoon, Haesung
    Kim, Jisoo
    Lim, Hyun Ji
    Kamiyama, Naohisa
    Oguri, Takuma
    Koh, Hong
    Lee, Mi-Jung
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2022, 48 (06) : 1070 - 1077
  • [4] Measurement of liver blood volume using a macromolecular MRI contrast agent at equilibrium
    Blustajn, J
    Cuenod, CA
    Clement, O
    Siauve, N
    VuilleminBodaghi, V
    Frija, G
    MAGNETIC RESONANCE IMAGING, 1997, 15 (04) : 415 - 421
  • [5] Measurement of liver volume using spiral CT and the curved line and cubic spline algorithms: reproducibility and interobserver variation
    Sandrasegaran, K
    Kwo, PW
    DiGirolamo, D
    Stockberger, SM
    Cummings, OW
    Kopecky, KK
    ABDOMINAL IMAGING, 1999, 24 (01): : 61 - 65
  • [6] A hemoglobin and volume measurement sensor for point of care testing analyzer using MEMS process
    Tanabe, Rikiya
    Hata, Seiichi
    Shimokohbe, Akira
    IEEJ Transactions on Sensors and Micromachines, 2007, 127 (05) : 267 - 271
  • [7] Dual-Mode Batteryless Ammonia Sensor Using Polyvinyl Alcohol-Reinforced Clitoria ternatea Anthocyanin With Graphene Nanoplatelets for Enhanced Food Quality Monitoring
    Kurian, Thiresamary
    Tan, Chun-Hui
    Chee, Pei-Song
    Ganesan, Vinod
    IEEE SENSORS JOURNAL, 2024, 24 (11) : 17424 - 17432
  • [8] Sonographic Assessment of Fatty Liver Infiltration Using the Measurement of Para- and Perirenal Fat Thickness
    Kawasaki, Satsuki
    Hasegawa, Osamu
    Satoh, Shinobu
    Numata, Kazushi
    Terauchi, Yasuo
    JOURNAL OF CLINICAL ULTRASOUND, 2010, 38 (09) : 470 - 474
  • [9] Risk Stratification of Advanced Fibrosis in Patients With Human Immunodeficiency Virus and Hepatic Steatosis Using the Fibrosis-4, Nonalcoholic Fatty Liver Disease Fibrosis, and BARD Scores
    Yendewa, George A.
    Khazan, Ana
    Jacobson, Jeffrey M.
    OPEN FORUM INFECTIOUS DISEASES, 2024, 11 (02):
  • [10] Multi-omics analysis of a fatty liver model using human hepatocyte chimeric mice
    Ichikawa, Akemi
    Miki, Daiki
    Hayes, C. Nelson
    Teraoka, Yuji
    Nakahara, Hikaru
    Tateno, Chise
    Ishida, Yuji
    Chayama, Kazuaki
    Oka, Shiro
    SCIENTIFIC REPORTS, 2024, 14 (01)