Test-retest reliability of functional near-infrared spectroscopy during a finger-tapping and postural task in healthy older adults

被引:7
作者
de Rond, Veerle [1 ]
Gilat, Moran [1 ,2 ]
D'Cruz, Nicholas [1 ,3 ]
Hulzinga, Femke [1 ]
Orban de Xivry, Jean-Jacques [2 ,3 ]
Nieuwboer, Alice [1 ,2 ]
机构
[1] Katholieke Univ Leuven, Dept Rehabil Sci, Neurorehabil Res Grp, Leuven, Belgium
[2] Leuven Brain Inst, Leuven, Belgium
[3] Katholieke Univ Leuven, Dept Kinesiol, Motor Control & Neuroplast Res Grp, Leuven, Belgium
关键词
Functional near-infrared spectroscopy; ageing; test-retest; reliability; postural control; finger tapping; OXYGENATION; MOTOR; PEOPLE; VOLUME;
D O I
10.1117/1.NPh.10.2.025010
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Significance: Functional near-infrared spectroscopy (fNIRS) is increasingly employed in studies requiring repeated measurements, yet test-retest reliability is largely unknown. Aim: To investigate test-retest reliability during a postural and a finger-tapping task with and without cap-removal. Approach: Twenty healthy older adults performed a postural and a finger-tapping task. The tasks were repeated twice in one session and once the next day. A portable fNIRS system measured cortical hemodynamics (HbO(2)) in five regions of interest for the postural task and in the hand motor region for finger-tapping. Results: Test-retest reliability without cap-removal was excellent for the prefrontal cortex (PFC), the premotor cortex (PMC) and the somatosensory cortex (SSC) (intraclass correlation coefficient oICCTHORN >= 0.78), and fair for the frontal eye fields (FEF) and the supplementary motor area (SMA) (ICC >= 0.48). After cap-removal, reliability reduced for PFC and SSC (ICC = 0.50), became poor for SMA (ICC = 0.01) and PMC (ICC = 0.00) and remained good for FEF (ICC = 0.64). Similarly, good reliability (ICC = 0.66) was apparent for the hand motor region without cap-removal, which deteriorated after cap-removal (ICC = 0.38). Conclusions: Test-retest reliability of fNIRS measurements during two separate motor tasks in healthy older adults was fair to excellent when the cap remained in place. However, removing the fNIRS cap between measurements compromised reliability. (c) The Authors. Published by SPIE under a Creative Commons Attribution 4.0 International License. Distribution or reproduction of this work in whole or in part requires full attribution of the original publication, including its DOI.
引用
收藏
页数:20
相关论文
共 52 条
  • [1] Augusto G., 2018, SCI REP-UK, V8, DOI [10.1038/s41598-018-21716-z, DOI 10.1038/S41598-018-21716-Z]
  • [2] There is No test-retest reliability of brain activation induced by robotic passive hand movement: A functional NIRS study
    Bae, Sungjin
    Lee, Yonghee
    Chang, Pyung-Hun
    [J]. BRAIN AND BEHAVIOR, 2020, 10 (10):
  • [3] Autoregressive model based algorithm for correcting motion and serially correlated errors in fNIRS
    Barker, Jeffrey W.
    Aarabi, Ardalan
    Huppert, Theodore J.
    [J]. BIOMEDICAL OPTICS EXPRESS, 2013, 4 (08): : 1366 - 1379
  • [4] Reliability of near-infrared spectroscopy measures of cerebral oxygenation and blood volume during handgrip exercise in nondisabled and traumatic brain-injured subjects
    Bhambhani, Yagesh
    Maikala, Ram
    Farag, Mamdouh
    Rowland, Gary
    [J]. JOURNAL OF REHABILITATION RESEARCH AND DEVELOPMENT, 2006, 43 (07) : 845 - 856
  • [5] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [6] Inter-Session Reliability of Functional Near-Infrared Spectroscopy at the Prefrontal Cortex While Walking in Multiple Sclerosis
    Broscheid, Kim-Charline
    Hamacher, Dennis
    Lamprecht, Juliane
    Sailer, Michael
    Schega, Lutz
    [J]. BRAIN SCIENCES, 2020, 10 (09) : 1 - 15
  • [7] Functional near-infrared spectroscopy - An emerging neuroimaging modality
    Bunce, Scott C.
    Izzetoglu, Meltem
    Izzetoglu, Kurtulus
    Onaral, Banu
    Pourrezaei, Kambiz
    [J]. IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 2006, 25 (04): : 54 - 62
  • [8] Cockx H., 2022, FUNCTIONAL NEAR INFR, P1, DOI [10.31219/osf.io/xgnfh, DOI 10.31219/OSF.IO/XGNFH]
  • [9] A quantitative comparison of NIRS and fMRI across multiple cognitive tasks
    Cui, Xu
    Bray, Signe
    Bryant, Daniel M.
    Glover, Gary H.
    Reiss, Allan L.
    [J]. NEUROIMAGE, 2011, 54 (04) : 2808 - 2821
  • [10] Functional near infrared spectroscopy (NIRS) signal improvement based on negative correlation between oxygenated and deoxygenated hemoglobin dynamics
    Cui, Xu
    Bray, Signe
    Reiss, Allan L.
    [J]. NEUROIMAGE, 2010, 49 (04) : 3039 - 3046