Development and validation of high-performance thin layer chromatographic method for simultaneous quantitation of novel combination perindopril erbumine and moxonidine hydrochloride

被引:5
|
作者
Akabari, Ashok H. [1 ,3 ]
Surati, Jasmina [1 ]
Patel, Sagar [1 ]
Pathak, Bhumin [1 ]
Patel, Arun [1 ]
Patel, Chandani [1 ]
Patel, Sagarkumar K. [2 ]
机构
[1] Shree Naranjibhai Lalbhai Patel Coll Pharm, Dept Qual Assurance, Umrakh, Gujarat, India
[2] Labcorp Drug Dev Inc, Somerset, NJ USA
[3] Shree Naranjibhai Lalbhai Patel Coll Pharm, Umrakh, Gujarat, India
关键词
analytical method; anti-hypertensive agent; high-performance thin-layer chromatography method; moxonidine hydrochloride; perindopril erbumine; HUMAN PLASMA; AMLODIPINE; ARGININE; BULK;
D O I
10.1002/sscp.202300051
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The primary purpose of the present study was to develop and validate a high-performance thin-layer chromatography method for quantitatively determining an anti-hypertensive agent, perindopril erbumine, and moxonidine hydrochloride in bulk and synthetic mixture. The densitometric procedure was performed on aluminum thin-layer chromatography plates pre-coated with silica gel 60F254, employing a combination of dichloromethane: toluene: methanol: ammonia (7:1:2:0.1 v/v/v/v) as the mobile phase. The thin-layer chromatography scanner was operated in absorbance mode at a wavelength of 223 nm to evaluate densitograms. The linearity of the method was established in the range of 1000-5000 ng/band for perindopril erbumine and 40-200 ng/band for moxonidine hydrochloride; the correlation coefficient (r(2)) was 0.9993 and 0.9983, respectively. The values of a limit of detection (186.06 and 3.51 ng/band, respectively, for perindopril erbumine and moxonidine hydrochloride) and limit of quantification (620.23 and 11.73 ng/band, respectively, for perindopril erbumine and moxonidine hydrochloride) have demonstrated the sensitivity of the developed method. The reported process was precise in both intra-day and inter-day analysis; the percentage relative standard deviation of peak area was less than 2% and has an accuracy within 100 +/- 2%. The developed method has the potential to quantify perindopril erbumine and moxonidine hydrochloride from its synthetic mixture without any interference from other components or in quality control laboratories.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] APPLICATION OF STABILITY INDICATING HIGH PERFORMANCE THIN LAYER CHROMATOGRAPHIC METHOD FOR QUANTITATION OF DESVENLAFAXINE IN PHARMACEUTICAL DOSAGE FORM
    Pawar, Shubhangi M.
    Dhaneshwar, Sunil R.
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2012, 35 (1-4) : 499 - 510
  • [22] APPLICATION OF HIGH-PERFORMANCE THIN-LAYER CHROMATOGRAPHIC METHOD FOR THE SIMULTANEOUS DETERMINATION OF LAMIVUDINE AND TENOFOVIR DISOPROXIL FUMARATE IN PHARMACEUTICAL DOSAGE FORM
    Chandra, P.
    Rathore, A. S.
    Sathiyanarayanan, L.
    Mahadik, K. R.
    JOURNAL OF THE CHILEAN CHEMICAL SOCIETY, 2011, 56 (02) : 702 - 705
  • [23] Development and Validation of a Densitometric-High-Performance Thin-Layer Chromatographic Method for Quantitative Analysis of Amitriptyline in Gastric Lavage
    Turkmen, Zeynep
    Mercan, Selda
    Bavunoglu, Isil
    Cengiz, Salih
    JPC-JOURNAL OF PLANAR CHROMATOGRAPHY-MODERN TLC, 2013, 26 (06) : 496 - 501
  • [24] Validated High-Performance Thin-Layer Chromatographic Method for Quantitation of Fluvoxamine in the Presence of Degradation Products Formed under ICH Recommended Stress Conditions
    Pawar, Shubhangi Mahadev
    Dhaneshwar, Sunil Rajaram
    JPC-JOURNAL OF PLANAR CHROMATOGRAPHY-MODERN TLC, 2012, 25 (04) : 338 - 343
  • [25] Development and Validation of a High-Performance Liquid Chromatographic Method for Determination of Eprosartan in Bulk Drug and Tablets
    Patel, Harsha U.
    Suhagia, Bhanubhai N.
    Patel, Chhaganbhai N.
    JOURNAL OF AOAC INTERNATIONAL, 2010, 93 (06) : 1862 - 1867
  • [26] High-performance thin-layer chromatographic methods for the determination of febuxostat and febuxostat/diclofenac combination in human plasma
    El-Yazbi, Fawzi A.
    Amin, Omayma A.
    El-Kimary, Eman, I
    Khamis, Essam F.
    Younis, Sameh E.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2018, 1086 : 89 - 96
  • [27] Novel determination of a new antiviral combination; sofosbuvir and velpatasvir by high performance thin layer chromatographic method; application to real human samples
    Rezk, Mamdouh R.
    Monir, Hany H.
    Marzouk, Hoda M.
    MICROCHEMICAL JOURNAL, 2019, 146 : 828 - 834
  • [28] Stability-Indicating High-Performance Thin-Layer Chromatographic Method for the Simultaneous Determination of Quercetin and Resveratrol in the Lipid-Based Nanoformulation
    Imran, Mohammad
    Iqubal, Mohammad Kashif
    Ahmad, Sayeed
    Ali, Javed
    Baboota, Sanjula
    JPC-JOURNAL OF PLANAR CHROMATOGRAPHY-MODERN TLC, 2019, 32 (05) : 393 - 400
  • [29] Simultaneous High-Performance Thin-Layer Chromatographic Determination of Ondansetron and Pantoprazole in Their Pure Forms and Spiked Human Plasma
    Magda Elhenawee
    Hanaa Saleh
    Roshdy E. Saraya
    JPC – Journal of Planar Chromatography – Modern TLC, 2019, 32 : 149 - 156
  • [30] Simultaneous High-Performance Thin-Layer Chromatographic Determination of Ondansetron and Pantoprazole in Their Pure Forms and Spiked Human Plasma
    Elhenawee, Magda
    Saleh, Hanaa
    Saraya, Roshdy E.
    JPC-JOURNAL OF PLANAR CHROMATOGRAPHY-MODERN TLC, 2019, 32 (02) : 149 - 156