Development and validation of high-performance thin layer chromatographic method for simultaneous quantitation of novel combination perindopril erbumine and moxonidine hydrochloride

被引:5
|
作者
Akabari, Ashok H. [1 ,3 ]
Surati, Jasmina [1 ]
Patel, Sagar [1 ]
Pathak, Bhumin [1 ]
Patel, Arun [1 ]
Patel, Chandani [1 ]
Patel, Sagarkumar K. [2 ]
机构
[1] Shree Naranjibhai Lalbhai Patel Coll Pharm, Dept Qual Assurance, Umrakh, Gujarat, India
[2] Labcorp Drug Dev Inc, Somerset, NJ USA
[3] Shree Naranjibhai Lalbhai Patel Coll Pharm, Umrakh, Gujarat, India
关键词
analytical method; anti-hypertensive agent; high-performance thin-layer chromatography method; moxonidine hydrochloride; perindopril erbumine; HUMAN PLASMA; AMLODIPINE; ARGININE; BULK;
D O I
10.1002/sscp.202300051
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The primary purpose of the present study was to develop and validate a high-performance thin-layer chromatography method for quantitatively determining an anti-hypertensive agent, perindopril erbumine, and moxonidine hydrochloride in bulk and synthetic mixture. The densitometric procedure was performed on aluminum thin-layer chromatography plates pre-coated with silica gel 60F254, employing a combination of dichloromethane: toluene: methanol: ammonia (7:1:2:0.1 v/v/v/v) as the mobile phase. The thin-layer chromatography scanner was operated in absorbance mode at a wavelength of 223 nm to evaluate densitograms. The linearity of the method was established in the range of 1000-5000 ng/band for perindopril erbumine and 40-200 ng/band for moxonidine hydrochloride; the correlation coefficient (r(2)) was 0.9993 and 0.9983, respectively. The values of a limit of detection (186.06 and 3.51 ng/band, respectively, for perindopril erbumine and moxonidine hydrochloride) and limit of quantification (620.23 and 11.73 ng/band, respectively, for perindopril erbumine and moxonidine hydrochloride) have demonstrated the sensitivity of the developed method. The reported process was precise in both intra-day and inter-day analysis; the percentage relative standard deviation of peak area was less than 2% and has an accuracy within 100 +/- 2%. The developed method has the potential to quantify perindopril erbumine and moxonidine hydrochloride from its synthetic mixture without any interference from other components or in quality control laboratories.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Development and Validation of a Stability-Indicating High-Performance Thin-Layer Chromatographic Method for the Simultaneous Quantification of Sparfloxacin and Flurbiprofen in Nanoparticulate Formulation
    Tariq, Mohammad
    Iqbal, Zeenat
    Ali, Javed
    Baboota, Sanjula
    Parveen, Rabea
    Mirza, Mohd. Aamir
    Ahmad, Sayeed
    Sahni, Jasjeet Kaur
    JPC-JOURNAL OF PLANAR CHROMATOGRAPHY-MODERN TLC, 2014, 27 (02) : 124 - 131
  • [2] Comparative High-Performance Liquid Chromatographic and High-Performance Thin-Layer Chromatographic Study for the Simultaneous Determination of Dapagliflozin and Metformin Hydrochloride in Bulk and Pharmaceutical Formulation
    Nasser, Sally
    Salama, Ismail
    Mostafa, Samia M.
    Elgawish, Mohamed Saleh
    JPC-JOURNAL OF PLANAR CHROMATOGRAPHY-MODERN TLC, 2018, 31 (06) : 469 - 476
  • [3] Development and validation of high-performance thin layer chromatographic method for concurrent estimation of dapagliflozin and vildagliptin in combined tablet
    Sen, Ashim Kumar
    Khatariya, Satish B.
    Sen, Dhanya B.
    Maheshwari, Rajesh A.
    Akabari, Ashok H.
    Velmurugan, Ramaswamy
    SEPARATION SCIENCE PLUS, 2024, 7 (01)
  • [4] Synchronized Assessment of Lobeglitazone Sulfate and Metformin Hydrochloride in Tablet by Robust, High-performance Thin-layer Chromatographic Method
    Sen, Dhanya B.
    Baldha, Krunal
    Sen, Ashim Kumar
    Maheshwari, Rajesh A.
    Zanwar, Aarti S.
    Greeshma, K. P.
    Pradhan, Prasanna Kumar
    CURRENT PHARMACEUTICAL ANALYSIS, 2024, 20 (05) : 345 - 357
  • [5] Development and validation of a high-performance thin layer chromatography method for the determination of cholesterol concentration
    John, Jinu
    Reghuwanshi, Ankit
    Aravind, Usha K.
    Aravindakumar, C. T.
    JOURNAL OF FOOD AND DRUG ANALYSIS, 2015, 23 (02) : 219 - 224
  • [6] A versatile high-performance thin-layer chromatographic method for the simultaneous determination of five antihypertensive drugs: method validation and application to different pharmaceutical formulations
    Saeed, Salma
    Nadim, Ahmed H.
    Yehia, Ali M.
    Moustafa, Azza A.
    JPC-JOURNAL OF PLANAR CHROMATOGRAPHY-MODERN TLC, 2021, 34 (05) : 467 - 477
  • [7] Validated Reversed-Phase High-Performance Liquid Chromatographic and High-Performance Thin-Layer Chromatographic Methods for Simultaneous Analysis of Tamsulosin Hydrochloride and Dutasteride in Pharmaceutical Dosage Forms
    Patel, D. B.
    Patel, N. J.
    ACTA CHROMATOGRAPHICA, 2010, 22 (03) : 419 - 431
  • [8] Simultaneous quantification of perindopril erbumine, indapamide and amlodipine besylate in newer combination of anti-hypertensive drugs in pharmaceutical dosage form by thin layer chromatography method
    Patel, Kirtan
    Chhalotiya, Usmangani
    Kacchiya, Hetaben
    Patel, Jay
    Shah, Dimal
    Nagda, Dhruti
    SEPARATION SCIENCE PLUS, 2020, 3 (05) : 175 - 184
  • [9] Factorial Design for Development of a High-Performance Thin-Layer Chromatography Method for the Simultaneous Estimation of Abacavir Sulfate, Lamivudine Hydrochloride, and Dolutegravir Sodium
    Dave, Krupali
    Desai, Sonal
    JPC-JOURNAL OF PLANAR CHROMATOGRAPHY-MODERN TLC, 2018, 31 (06) : 489 - 495
  • [10] Development and validation of a high-performance thin layer chromatography method for the simultaneous determination of amoxicillin and clavulanic acid combinations in tablet dosage forms
    Asres, Esubalew
    Layloff, Thomas
    Ashenef, Ayenew
    HELIYON, 2023, 9 (12)