Closed Reduction and Percutaneous Pinning for Treatment of Proximal Interphalangeal Joint Pilon Fractures

被引:1
作者
Mazhar, Farid Najd [1 ]
Motaghi, Paniz [1 ,2 ]
机构
[1] Iran Univ Med Sci, Tehran, Iran
[2] Iran Univ Med Sci, Res Off Shafa Yahyaeian Orthoped Hosp, Bone & Joint Reconstruct Res Ctr, Sch Med,Dept Orthoped, Mojahedin Eslam St, Tehran 1416693491, Iran
来源
HAND-AMERICAN ASSOCIATION FOR HAND SURGERY | 2023年 / 18卷 / 01期
关键词
pilon; external fixation; close reduction; middle phalanx; PIP fracture; DYNAMIC EXTERNAL FIXATOR; PERSIAN VERSION; DISLOCATIONS;
D O I
10.1177/1558944721990774
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background:Proximal interphalangeal (PIP) joint pilon fractures are among the challenging hand injuries, which are often associated with a wide range of complications. This study aimed to report the clinical and radiological outcomes of closed reduction and percutaneous Kirschner wire (KW) insertion with or without bone cement application (for the fabrication of an external fixator) in the treatment of PIP joint pilon fractures.Methods:Twenty pilon fractures underwent closed reduction and percutaneous KW fixation through a modified technique. At the end of the follow-up period, 3 questionnaires-Quick Disabilities of the Arm, Shoulder, and Hand (Quick DASH), Visual Analogue Scale for pain, and Patient-Rated Wrist Evaluation-were completed. The radiological outcome was assessed by radiography. Range of motion, and grip and pinch strength were measured.Results:The mean follow-up period was 14.57 +/- 4.03 months (range, 12-20 months). The mean range of motion of PIP at the end of the follow-up period was 89.64 degrees +/- 10.82 degrees (range, 65 degrees-100 degrees). The mean difference in the range of motion in the contralateral side was 21.4 degrees +/- 13 degrees. The mean of the Quick DASH score was 13.50 +/- 2.92 (range, 11-21). Two patients had residual articular malalignment, and 3 patients had angular or rotational malunion.Conclusion:By treating pilon fractures with the proposed technique, we achieved a satisfactory outcome. The acceptable articular and axial alignment was achieved in 75% of patients, and complications were low. The flexibility of percutaneous KW insertion and handmade external fixators makes these approaches convenient for treating PIP joint pilon fractures.
引用
收藏
页码:40 / 47
页数:8
相关论文
共 20 条
[1]   INTERNAL-FIXATION OF HAND FRACTURES [J].
BARTON, N .
JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 1989, 14B (02) :139-142
[2]   Management of Proximal Interphalangeal Joint Fracture Dislocations [J].
Caggiano, Nicholas M. ;
Harper, Carl M. ;
Rozental, Tamara D. .
HAND CLINICS, 2018, 34 (02) :149-+
[3]   Outcomes of Closed Reduction and Periarticular Pinning of Base and Shaft Fractures of the Proximal Phalanx [J].
Eberlin, Kyle R. ;
Babushkina, Anna ;
Neira, Juliana Rojas ;
Mudgal, Chaitanya S. .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2014, 39 (08) :1524-1528
[4]  
Glickel SZ, 2000, HAND CLIN, V16, P333
[5]   Current Concepts in Treatment of Fracture-Dislocations of the Proximal Interphalangeal Joint [J].
Haase, Steven C. ;
Chung, Kevin C. .
PLASTIC AND RECONSTRUCTIVE SURGERY, 2014, 134 (06) :1246-1257
[6]  
Hassankhani GG, 2017, ARCH BONE JT SURG-AB, V5, P243
[7]   CONSERVATIVE TREATMENT OF FRACTURES OF THE PROXIMAL PHALANX: AN OPTION EVEN FOR UNSTABLE FRACTURE PATTERNS [J].
Held, Michael ;
Jordaan, Pieter ;
Laubscher, Maritz ;
Singer, Martin ;
Solomons, Michael .
JOURNAL OF HAND SURGERY-ASIAN-PACIFIC VOLUME, 2013, 18 (02) :229-234
[8]   Dynamic external fixation for pilon fractures of the interphalangeal joints [J].
Hynes, MC ;
Giddins, GEB .
JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 2001, 26 (02) :122-124
[9]  
Jafari D, 2017, Shafa Orthopedic Journal, V4, pe8352
[10]  
Kang R., 2002, J Am Soc Surg Hand, V2, P47, DOI [DOI 10.1053/JSSH.2002.33317, 10.1053/jssh.2002.33317]