Energy and Exergy Analysis of Cascade Mixed Refrigerant Joule-Thomson System with the Application of a Precooler

被引:0
作者
Yoon, Ji-Hoon [1 ]
Yoon, Jung-In [1 ]
Son, Chang-Hyo [1 ]
Seol, Sung-Hoon [1 ]
机构
[1] Pukyong Natl Univ, Coll Engn, Dept Refrigerat & Air Conditioning Engn, Busan 48513, South Korea
基金
新加坡国家研究基金会;
关键词
mixed refrigerant; Joule-Thomson; nonflammable refrigerant; precooler; energy and exergy analysis; PERFORMANCE; CYCLE; CIRCULATION; MIXTURE;
D O I
10.3390/en16196991
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This study proposes the application of a precooler to the cascade mixed refrigerant Joule-Thomson (CMR J-T) cycle, herein referred to as the precooled CMR J-T (PCMR J-T) system. The purpose of the precooler is to utilize the temperature gradient characteristics within the two-phase region exhibited by the non-azeotropic mixed refrigerant. The precooler reduces the temperature of the high-temperature gas exiting the compressor by using cooling water from the condenser, thereby decreasing the capacity requirements of the high-temperature cycle (HTC). The working fluid comprises a nonflammable mixed refrigerant (R218, R23, R14, and Ar), and simulations were conducted by varying the HTC evaporation temperature and cooling water temperature for energy and exergy analysis. Under the analysis conditions, the capacity of each component in the HTC can be reduced by over 45%, leading to a maximum increase of 21.6% in the system's coefficient of performance. Furthermore, the exergy destruction in the PCMR J-T system decreases along with the reduction in component capacity, with the most significant reduction occurring at the HTC expansion valve. The exergy efficiency of the system increases by up to 47.4%.
引用
收藏
页数:18
相关论文
共 38 条
[11]   Performance of a Linde-Hampson refrigerator operating from-120 °C to-60 °C with optimised R14-hydrocarbon mixtures exhibiting vapour-liquid-liquid equilibria [J].
Jerome, Sunil ;
Venkatarathnam, G. .
HEAT AND MASS TRANSFER, 2020, 56 (05) :1523-1535
[12]   Use of dual pressure Claude liquefaction cycles for complete and energy-efficient reliquefaction of boil-off gas in LNG carrier ships [J].
Kochunni, Sarun Kumar ;
Chowdhury, Kanchan .
ENERGY, 2020, 198
[13]   Design of high efficiency mixed refrigerant Joule-Thomson refrigerator for cooling HTS cable [J].
Lee, Jisung ;
Hwang, Gyuwan ;
Jeong, Sangkwon ;
Park, Byung Jun ;
Han, Young Hee .
CRYOGENICS, 2011, 51 (07) :408-414
[14]   Performance Characteristics of a Joule-Thomson Refrigeration System with Mixed Refrigerant Composition [J].
Lee, Kwang-Seok ;
Yoon, Jung-In ;
Son, Chang-Hyo ;
Lee, Joon-Hyuk ;
Moon, Choon-Geun ;
Yoo, Wook-Jin ;
Lee, Byeong-Chan .
HEAT TRANSFER ENGINEERING, 2021, 42 (13-14) :1087-1096
[15]  
LITTLE WA, 1994, ADV CRYOG ENG, V39, P1467
[16]   Thermodynamic analysis of a novel vapor-injection Joule-Thomson refrigeration cycle with a binary hydrocarbon mixture for-86? freezer [J].
Liu, Jiarui ;
Liu, Ye ;
Yu, Jianlin ;
Yan, Gang .
APPLIED THERMAL ENGINEERING, 2023, 230
[17]   Performance analysis of a modified ejector-enhanced auto-cascade refrigeration cycle [J].
Liu, Shuilong ;
Bai, Tao ;
Wei, Yuan ;
Yu, Jianlin .
ENERGY, 2023, 265
[18]   Experimental test on the performance of a -80 °C cascade refrigeration unit using refrigerants R290-R170 for COVID-19 vaccines storage [J].
Liu, Zhan ;
Bai, Minkai ;
Tan, Haihui ;
Ling, Yunzhi ;
Cao, Zhen .
JOURNAL OF BUILDING ENGINEERING, 2023, 63
[19]  
LONGSWORTH RC, 1995, CRYOCOOLERS 8, P537
[20]   Experimental investigation of cycle characteristics of a R23 and R600a based Joule-Thomson refrigerator [J].
Lu, Xianghua ;
Rui, Shengjun ;
He, Tao .
HEAT AND MASS TRANSFER, 2019, 55 (05) :1439-1446