A Dual-Chamber Leadless Pacemaker

被引:127
作者
Knops, Reinoud E. [1 ]
Reddy, Vivek Y. [2 ,11 ]
Ip, James E. [3 ]
Doshi, Rahul
Exner, Derek V. [5 ]
Defaye, Pascal [6 ]
Canby, Robert [4 ,7 ]
Bongiorni, Maria Grazia [8 ]
Shoda, Morio [9 ]
Hindricks, Gerhard [10 ]
Neuzil, Petr [11 ]
Rashtian, Mayer [12 ]
Breeman, Karel T. N. [1 ]
Nevo, Jordan R. [13 ]
Ganz, Leonard [13 ]
Hubbard, Chris [13 ]
Cantillon, Daniel J. [14 ]
机构
[1] Univ Amsterdam, Med Ctr, Amsterdam, Netherlands
[2] Icahn Sch Med Mt Sinai, New York, NY USA
[3] New York Presbyterian Hosp, Weill Cornell Med, New York, NY USA
[4] HonorHlth Cardiac Arrhythmia Grp, Scottsdale, AZ USA
[5] Foothills Med Ctr, Calgary, AB, Canada
[6] CHRU Albert Michallon, Grenoble, France
[7] Texas Cardiac Arrhythmia Inst, Austin, TX USA
[8] Azienda Osped Univ Pisana, Pisa, Italy
[9] Tokyo Womens Med Univ, Tokyo, Japan
[10] Deutsch Herzzentrum Charite, Berlin, Germany
[11] Na Homolce Hosp, Prague, Czech Republic
[12] Huntington Mem Hosp, Pasadena, CA USA
[13] Abbott Med, Sylmar, CA USA
[14] Cleveland Clin, Cleveland, OH USA
关键词
ATRIAL-FIBRILLATION; COMPLICATIONS; IMPLANTATION; PREDICTORS;
D O I
10.1056/NEJMoa2300080
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Single-chamber ventricular leadless pacemakers do not support atrial pacing or consistent atrioventricular synchrony. A dual-chamber leadless pacemaker system consisting of two devices implanted percutaneously, one in the right atrium and one in the right ventricle, would make leadless pacemaker therapy a treatment option for a wider range of indications. METHODS We conducted a prospective, multicenter, single-group study to evaluate the safety and performance of a dual-chamber leadless pacemaker system. Patients with a conventional indication for dual-chamber pacing were eligible for participation. The primary safety end point was freedom from complications (i.e., device- or procedurerelated serious adverse events) at 90 days. The first primary performance end point was a combination of adequate atrial capture threshold and sensing amplitude at 3 months. The second primary performance end point was at least 70% atrioventricular synchrony at 3 months while the patient was sitting. RESULTS Among the 300 patients enrolled, 190 (63.3%) had sinus-node dysfunction and 100 (33.3%) had atrioventricular block as the primary pacing indication. The implantation procedure was successful (i.e., two functioning leadless pacemakers were implanted and had established implant-to-implant communication) in 295 patients (98.3%). A total of 35 device- or procedure-related serious adverse events occurred in 29 patients. The primary safety end point was met in 271 patients (90.3%; 95% confidence interval [CI], 87.0 to 93.7), which exceeded the performance goal of 78% (P<0.001). The first primary performance end point was met in 90.2% of the patients (95% CI, 86.8 to 93.6), which exceeded the performance goal of 82.5% (P<0.001). The mean (+/- SD) atrial capture threshold was 0.82 +/- 0.70 V, and the mean P-wave amplitude was 3.58 +/- 1.88 mV. Of the 21 patients (7%) with a P-wave amplitude of less than 1.0 mV, none required device revision for inadequate sensing. At least 70% atrioventricular synchrony was achieved in 97.3% of the patients (95% CI, 95.4 to 99.3), which exceeded the performance goal of 83% (P<0.001). CONCLUSIONS The dual-chamber leadless pacemaker system met the primary safety end point and provided atrial pacing and reliable atrioventricular synchrony for 3 months after implantation. (Funded by Abbott Medical; Aveir DR i2i ClinicalTrials.gov number, NCT05252702.)
引用
收藏
页码:2360 / 2370
页数:11
相关论文
共 23 条
[1]   Silent atrial fibrillation in pacemaker early post-implantation period: an unintentionally provoked situation? [J].
Benezet-Mazuecos, Juan ;
Antonio Iglesias, Jose ;
Cortes, Marcelino ;
Manuel Rubio, Jose ;
Jose de la Vieja, Juan ;
del Rio, Ana ;
Sanchez-Borque, Pepa ;
Miracle, Angel ;
Farre, Jeronimo .
EUROPACE, 2018, 20 (05) :758-763
[2]   Wireless Communication Between Paired Leadless Pacemakers for Dual-Chamber Synchrony [J].
Cantillon, Daniel J. ;
Gambhir, Alok ;
Banker, Rajesh ;
Rashtian, Mayer ;
Doshi, Rahul ;
Badie, Nima ;
Booth, Daniel ;
Yang, Weiqun ;
Nee, Peter ;
Fishler, Matthew ;
Ligon, David ;
Neuzil, Petr ;
Knops, Reinoud E. .
CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2022, 15 (07) :456-463
[3]   Comparative study of acute and mid-term complications with leadless and transvenous cardiac pacemakers [J].
Cantillon, Daniel J. ;
Dukkipati, Srinivas R. ;
Ip, John H. ;
Exner, Derek V. ;
Niazi, Imran K. ;
Banker, Rajesh S. ;
Rashtian, Mayer ;
Plunkitt, Kenneth ;
Tomassoni, Gery F. ;
Nabutovsky, Yelena ;
Davis, Kevin J. ;
Reddy, Vivek Y. .
HEART RHYTHM, 2018, 15 (07) :1023-1030
[4]  
Cantillon Daniel J, 2017, JACC Clin Electrophysiol, V3, P1296, DOI 10.1016/j.jacep.2017.05.007
[5]   Leadless vs. transvenous single-chamber ventricular pacing in the Micra CED study: 2-year follow-up [J].
El-Chami, Mikhael F. ;
Bockstedt, Lindsay ;
Longacre, Colleen ;
Higuera, Lucas ;
Stromberg, Kurt ;
Crossley, George ;
Kowal, Robert C. ;
Piccini, Jonathan P. .
EUROPEAN HEART JOURNAL, 2022, 43 (12) :1207-1215
[6]   Updated performance of the Micra transcatheter pacemaker in the real-world setting: A comparison to the investigational study and a transvenous historical control [J].
El-Chami, Mikhael F. ;
Al-Samadi, Faisal ;
Clementy, Nicolas ;
Garweg, Christophe ;
Luis Martinez-Sande, Jose ;
Piccini, Jonathan P. ;
Iacopino, Saverio ;
Lloyd, Michael ;
Vinolas Prat, Xavier ;
Jacobsen, Michael Dilou ;
Ritter, Philippe ;
Johansen, Jens Brock ;
Tondo, Claudio ;
Liu, Fang ;
Fagan, Dedra H. ;
Eakley, Alyssa K. ;
Roberts, Paul R. .
HEART RHYTHM, 2018, 15 (12) :1800-1807
[7]   Complications arising after implantation of DDD pacemakers: The MOST experience [J].
Ellenbogen, KA ;
Hellkamp, AS ;
Wilkoff, BL ;
Camunas, JL ;
Love, JC ;
Hadjis, TA ;
Lee, KL ;
Lamas, GA .
AMERICAN JOURNAL OF CARDIOLOGY, 2003, 92 (06) :740-741
[8]   Randomized trial of pacemaker and lead system for safe scanning at 1.5 Tesla [J].
Gimbel, J. Rod ;
Bello, David ;
Schmitt, Matthias ;
Merkely, Bela ;
Schwitter, Juerg ;
Hayes, David L. ;
Sommer, Torsten ;
Schloss, Edward J. ;
Chang, Yanping ;
Willey, Sarah ;
Kanal, Emanuel .
HEART RHYTHM, 2013, 10 (05) :685-691
[9]  
Glikson M, 2021, EUR HEART J, V42, P3427, DOI [10.1093/eurheartj/ehab364, 10.1093/europace/euab232]
[10]   Long-term performance of active-fixation pacing leads: A prospective study [J].
Kistler, PM ;
Liew, G ;
Mond, HG .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2006, 29 (03) :226-230