Effective lung ventilation estimation based on 4D CT image registration and supervoxels

被引:3
|
作者
Xue, Peng [1 ]
Fu, Yu [1 ]
Zhang, Jingyang [2 ]
Ma, Lei [3 ,4 ]
Ren, Meirong [1 ]
Zhang, Zhili [1 ]
Dong, Enqing [1 ]
机构
[1] Shandong Univ, Sch Mech Elect & Informat Engn, Weihai 264209, Peoples R China
[2] Shanghai Jiao Tong Univ, Sch Biomed Engn, Shanghai 201204, Peoples R China
[3] Univ North Carolina Chapel Hill, Dept Radiol, Chapel Hill, NC 27599 USA
[4] Univ North Carolina Chapel Hill, BRIC, Chapel Hill, NC 27599 USA
基金
中国国家自然科学基金;
关键词
4D CT; CT ventilation estimation; Image registration; Supervoxel clustering; PULMONARY VENTILATION; MOTION ESTIMATION; SPECT; QUANTIFICATION; REGULARIZATION; EXPANSION; PERFUSION;
D O I
10.1016/j.bspc.2022.104074
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Most computed tomography (CT)-derived ventilation estimation methods rely on deformation fields of image registration to track the volume variations of each voxel, which are easily affected by image registration results and motion artifacts of four-dimensional (4D) CT images. To attack these problems, a lung ventilation estimation method based on 4D CT image registration and supervoxels is proposed in this paper. In order to avoid estimation errors caused by image artifacts and noises in the methods of directly estimating voxel-wise ventilation, images corresponding to maximum exhale phase are represented by multi-level supervoxels. Then, according to the relationship between registered CT values in Hounsfield units (HU) and regional volume change, a ventilation estimation method is designed to calculate the whole ventilation of each supervoxel. To accurately recover the ventilation of each voxel from the supervoxel region, a linear programming model is established to obtain the ventilation of each voxel, and the final estimated lung ventilation image is obtained by averaging the recovered results of all supervoxels layers. To evaluate our proposed ventilation estimation method, we calculate voxel-wise Spearman coefficient rs and Dice similarity coefficient (DSC for low function lung DSClow and high function lung DSChigh) of various CT-derived ventilation methods on VAMPIRE dataset. The experimental results on VAMPIRE dataset show that the average rs values between our proposed method can achieve 0.38 (-0.17-0.70). Accordingly, the average DSClow and DSChigh values of our proposed method are 0.40 (0.17-0.67) and 0.36 (0.08-0.61) respectively.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Evaluation of Elekta 4D cone beam CT-based automatic image registration for radiation treatment of lung cancer
    Li, Jun
    Harrison, Amy
    Yu, Yan
    Xiao, Ying
    Werner-Wasik, Maria
    Lu, Bo
    BRITISH JOURNAL OF RADIOLOGY, 2015, 88 (1053):
  • [22] Phase Correlated Image Registration to 4D CT for Liver Stereotactic Radiosurgery with Image Guidance CT
    Juh, R.
    Suh, T.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [23] GDL-FIRE4D: Deep Learning-Based Fast 4D CT Image Registration
    Sentker, Thilo
    Madesta, Frederic
    Werner, Rene
    MEDICAL IMAGE COMPUTING AND COMPUTER ASSISTED INTERVENTION - MICCAI 2018, PT I, 2018, 11070 : 765 - 773
  • [24] Multi-Frequency Oscillatory Ventilation Minimizes Spatial Gradients of Regional Strain Using 4D CT Image Registration in Porcine Lung Injury
    Herrmann, J.
    Gerard, S. E.
    Shao, W.
    Reinhardt, J. M.
    Christensen, G. E.
    Hoffman, E. A.
    Hawley, M. L.
    Kaczka, D. W.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2019, 199
  • [25] Novel Technique for Dynamic Lung Ventilation Imaging Based On Wide Coverage 4D CT
    Neal, B.
    Kipritidis, J.
    Kohno, R.
    Matsumoto, S.
    Yamamoto, T.
    MEDICAL PHYSICS, 2014, 41 (06) : 557 - 557
  • [26] Image interpolation in 4D CT using a BSpline deformable registration model
    Schreibmann, E
    Chen, GTY
    Xing, L
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 64 (05): : 1537 - 1550
  • [27] Image interpolation in 4D CT using a BSpline deformable registration model
    Schreibmann, E
    Yang, Y
    Boyer, A
    Li, T
    Xing, L
    MEDICAL PHYSICS, 2005, 32 (06) : 1924 - 1924
  • [28] Image Registration with Sliding Motion Constraints for 4D CT Motion Correction
    Derksen, Alexander
    Heldmann, Stefan
    Polzin, Thomas
    Berkels, Benjamin
    BILDVERARBEITUNG FUR DIE MEDIZIN 2015: ALGORITHMEN - SYSTEME - ANWENDUNGEN, 2015, : 335 - 340
  • [29] Evaluating lung motion variations in repeated 4D CT studies using inverse consistent image registration
    Lu, W.
    Song, J. H.
    Christensen, G. E.
    Parikh, P. J.
    Zhao, T.
    Hubenschmidt, J. P.
    Bradley, J. D.
    Low, D. A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S606 - S607
  • [30] Evaluating lung motion variations in repeated 4D CT studies using inverse consistent image registration
    Lu, W.
    Song, J.
    Christensen, G.
    Parikh, P.
    Zhao, T.
    Hubenschmidt, J.
    Bradley, J.
    Low, D.
    MEDICAL PHYSICS, 2006, 33 (06) : 2033 - 2033