Optimization of workflow for detection of brain metastases at 3T: is a black-blood MTC prepared 3D T1 used alone robust enough to replace the combination of conventional 3D T1 and the black-blood 3D T1 MTC?

被引:2
作者
Chkili, Sophia [1 ]
Lefebvre, Yolene [1 ]
Chao, Shih-Li [1 ]
Bali, Maria Antonietta [1 ]
Lemort, Marc [1 ]
Coquelet, Nicolas [1 ]
机构
[1] Inst Jules Bordet, Dept Radiol, 90 Rue Meylemeersch, B-1070 Brussels, Belgium
关键词
Brain metastases; Contrast enhancement; T1-weighted sequence; Magnetization transfer contrast; Black-blood; Vessel suppression; WHITE-MATTER HYPERINTENSITIES; SPINAL-CORD; CONTRAST; RADIOSURGERY; MANAGEMENT; DIAGNOSIS; ECHO;
D O I
10.1007/s00234-023-03143-8
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
PurposeSampling perfection with application-optimized contrasts by using different flip angle evolutions (SPACE) is a black-blood 3D T1-weighted (T1w) magnetic resonance imaging (MRI) sequence that has shown robust performance for brain metastases detection. However, this could generate false positive results due to suboptimal blood signal suppression. For that reason, SPACE is used in our institution alongside a non-black-blood T1w sequence: volumetric interpolated breath-hold examination (VIBE). Our study aims to (i) evaluate the diagnostic accuracy of SPACE compared to its use in combination with VIBE, (ii) investigate the effect of radiologist's experience in the sequence's performance, and (iii) analyze causes of discordants results.MethodsFour hundred seventy-three 3T MRI scans were retrospectively analyzed following a monocentric study design. Two studies were formed: one including SPACE alone and one combining both sequences (SPACE + VIBE, the reference). An experienced neuroradiologist and a radiology trainee independently reviewed the images of each study and reported the number of brain metastases. The sensitivity (Se) and specificity (Sp) of SPACE compared to SPACE + VIBE in metastases detection were reported. Diagnostic accuracy of SPACE compared to SPACE + VIBE was assessed by using McNemar's test. Significance was set at p < 0.05. Cohen's kappa was used for inter-method and inter-observer variability.ResultsNo significant difference was found between the two methods, with SPACE having a Se > 93% and a Sp > 87%. No effect of readers' experience was disclosed.ConclusionIndependently of radiologist's experience, SPACE alone is robust enough to replace SPACE + VIBE for brain metastases detection.
引用
收藏
页码:1133 / 1141
页数:9
相关论文
共 39 条
[31]  
Singh SK, 2002, AM J NEURORADIOL, V23, P817
[32]   Diagnosis and treatment of brain metastases from solid tumors: guidelines from the European Association of Neuro-Oncology (EANO) [J].
Soffietti, Riccardo ;
Abacioglu, Ufuk ;
Baumert, Brigitta ;
Combs, Stephanie E. ;
Kinhult, Sara ;
Kros, Johan M. ;
Marosi, Christine ;
Metellus, Philippe ;
Radbruch, Alexander ;
Freixa, Salvador S. Villa ;
Brada, Michael ;
Carapella, Carmine M. ;
Preusser, Matthias ;
Le Rhun, Emilie ;
Ruda, Roberta ;
Tonn, Joerg C. ;
Weber, Damien C. ;
Weller, Michael .
NEURO-ONCOLOGY, 2017, 19 (02) :162-174
[33]  
Spilt A, 2006, AM J NEURORADIOL, V27, P1964
[34]   The detectability of brain metastases using contrast-enhanced spin-echo or gradient-echo images: a systematic review and meta-analysis [J].
Suh, Chong Hyun ;
Jung, Seung Chai ;
Kim, Kyung Won ;
Pyo, Junhee .
JOURNAL OF NEURO-ONCOLOGY, 2016, 129 (02) :363-371
[35]   MR IMAGING OF THE CRANIAL MENINGES WITH EMPHASIS ON CONTRAST ENHANCEMENT AND MENINGEAL CARCINOMATOSIS [J].
SZE, G ;
SOLETSKY, S ;
BRONEN, R ;
KROL, G .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1989, 153 (05) :1039-1049
[36]   Improved Black-Blood Imaging Using DANTE-SPACE for Simultaneous Carotid and Intracranial Vessel Wall Evaluation [J].
Xie, Yibin ;
Yang, Qi ;
Xie, Guoxi ;
Pang, Jianing ;
Fan, Zhaoyang ;
Li, Debiao .
MAGNETIC RESONANCE IN MEDICINE, 2016, 75 (06) :2286-2294
[37]   Computer-Aided Detection of Metastatic Brain Tumors Using Magnetic Resonance Black-Blood Imaging [J].
Yang, Seungwook ;
Nam, Yoonho ;
Kim, Min-Oh ;
Kim, Eung Yeop ;
Park, Jaeseok ;
Kim, Dong-Hyun .
INVESTIGATIVE RADIOLOGY, 2013, 48 (02) :113-119
[38]   A prospective pilot study of two-session Gamma Knife surgery for large metastatic brain tumors [J].
Yomo, Shoji ;
Hayashi, Motohiro ;
Nicholson, Claire .
JOURNAL OF NEURO-ONCOLOGY, 2012, 109 (01) :159-165
[39]   Improvement of T1 Contrast in Whole-brain Black-blood Imaging using Motion-sensitized Driven-equilibrium Prepared 3D Turbo Spin Echo (3D MSDE-TSE) [J].
Yoneyama, Masami ;
Nakamura, Masanobu ;
Takahara, Taro ;
Takemura, Atsushi ;
Obara, Makoto ;
Tabuchi, Takashi ;
Tatsuno, Satoshi ;
Sawano, Seishi .
MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2014, 13 (01) :61-65