Time in Range and Pregnancy Outcomes in People with Diabetes Using Continuous Glucose Monitoring

被引:9
|
作者
Bartal, Michal Fishel [1 ,3 ]
Cornthwaite, Joycelyn A. Ashby A. [1 ]
Ghafir, Danna [1 ]
Ward, Clara [1 ]
Ortiz, Gladys [1 ]
Louis, Aleaha [1 ]
Cornthwaite, John [2 ]
Chauhan, Suneet S. P. [1 ]
Sibai, Baha M. [1 ]
机构
[1] Univ Texas Hlth Sci Ctr Houston, McGovern Med Sch, Dept Obstet Gynecol & Reprod Sci, Div Maternal Fetal Med, Houston, TX USA
[2] Rice Univ, Dept Earth Environm & Planetary Sci, Houston, TX USA
[3] Univ Texas Hlth Sci Ctr Houston UTHlth, McGovern Med Sch, Dept Obstet Gynecol & Reprod Sci, Div Maternal Fetal Med, 6431 Fannin St,Suite 3-264, Houston, TX 77030 USA
关键词
neonatal morbidity; hypertensive disorder of pregnancy; continuous glucose monitoring; time in range; TASK-FORCE; WOMEN; BENEFITS; MELLITUS; TYPE-1;
D O I
10.1055/a-1904-9279
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective The international consensus on continuous glucose monitoring (CGM) recommends time in range (TIR) target of > 70% for pregnant people. Our aim was to compare outcomes between pregnant people with TIR & LE; versus > 70%.Study Design This study was a retrospective study of all people using CGM during pregnancy from January 2017 to May 2021 at a tertiary care center. All people with pregestational diabetes who used CGM and delivered at our center were included in the analysis. Primary neonatal outcome included any of the following: large for gestational age, neonatal intensive care unit (NICU) admission, need for intravenous (IV) glucose, or respiratory distress syndrome (RDS). Maternal outcomes included hypertensive disorders of pregnancy and delivery outcomes. Logistic regression was used to estimate unadjusted and adjusted odds ratios (aORs) with 95% confidence intervals (CIs).Results Of 78 people managed with CGM, 65 (80%) met inclusion criteria. While 33 people (50.1%) had TIR & LE;70%, 32 (49.2%) had TIR > 70%. People with TIR >= 70% were more likely to be younger, have a lower body mass index, and have type 1 diabetes than those with TIR > 70%. After multivariable regression, there was no difference in the composite neonatal outcome between the groups (aOR: 0.56, 95% CI: 0.16-1.92). However, neonates of people with TIR & LE;70% were more likely to be admitted to the NICU ( p = 0.035), to receive IV glucose ( p = 0.005), to have RDS ( p = 0.012), and had a longer hospital stay ( p = 0.012) compared with people with TIR > 70%. Furthermore, people with TIR & LE;70% were more likely to develop hypertensive disorders ( p = 0.04) than those with TIR > 70%.Conclusion In this cohort, the target of TIR > 70% was reached in about one out of two people with diabetes using CGM, which correlated with a reduction in neonatal and maternal complications.
引用
收藏
页码:461 / 466
页数:6
相关论文
共 50 条
  • [1] Continuous Glucose Monitoring and Time in Range: Association with Adverse Outcomes among People with Type 2 or Gestational Diabetes Mellitus
    Bitar, Ghamar
    Cornthwaite, Joycelyn A.
    Sadek, Sandra
    Ghorayeb, Tala
    Daye, Nahla
    Nazeer, Sarah
    Ghafir, Danna
    Cornthwaite, John
    Chauhan, Suneet P.
    Sibai, Baha M.
    Bartal, Michal Fishel
    AMERICAN JOURNAL OF PERINATOLOGY, 2024, 41 : e1370 - e1377
  • [2] Continuous glucose monitoring targets in type 1 diabetes pregnancy: every 5% time in range matters
    Murphy, Helen R.
    DIABETOLOGIA, 2019, 62 (07) : 1123 - 1128
  • [3] Continuous glucose monitoring and insulin pump therapy for diabetes in pregnancy
    Combs, C. Andrew
    JOURNAL OF MATERNAL-FETAL & NEONATAL MEDICINE, 2012, 25 (10) : 2025 - 2027
  • [4] Continuous glucose monitoring targets in type 1 diabetes pregnancy: every 5% time in range matters
    Helen R. Murphy
    Diabetologia, 2019, 62 : 1123 - 1128
  • [5] Impact of continuous glucose monitoring on pregnancy outcomes in women with pregestational diabetes
    Hinojal, Isabel
    Chimenea, Angel
    Antinolo, Guillermo
    Garcia-Diaz, Lutgardo
    ACTA DIABETOLOGICA, 2025,
  • [6] Continuous glucose monitoring defined time-in-range is associated with sudomotor dysfunction in type 2 diabetes
    Guo, Qing-Yu
    Lu, Bin
    Guo, Zhan-Hong
    Feng, Zhou-Qin
    Yuan, Yan-Yu
    Jin, Xu-Guang
    Zang, Pu
    Gu, Ping
    Shao, Jia-Qing
    WORLD JOURNAL OF DIABETES, 2020, 11 (11) : 489 - 500
  • [7] Expert Recommendations for Using Time-in-Range and Other Continuous Glucose Monitoring Metrics to Achieve Patient-Centered Glycemic Control in People With Diabetes
    Bellido, Virginia
    Aguilera, Eva
    Cardona-Hernandez, Roque
    Diaz-Soto, Gonzalo
    Perez de Villar, Noemi Gonzalez
    Picon-Cesar, Maria J.
    Ampudia-Blasco, Francisco Javier
    JOURNAL OF DIABETES SCIENCE AND TECHNOLOGY, 2023, 17 (05): : 1326 - 1336
  • [8] Association of Continuous Glucose Monitoring Metrics With Pregnancy Outcomes in Patients With Preexisting Diabetes
    Sanusi, Ayodeji A.
    Xue, Yumo
    Mcilwraith, Claire
    Howard, Hannah
    Brocato, Brian E.
    Casey, Brian
    Szychowski, Jeff M.
    Battarbee, Ashley N.
    DIABETES CARE, 2024, 47 (01) : 89 - 96
  • [9] Progress and indication for use of continuous glucose monitoring in patients with diabetes in pregnancy: a review
    Song, Yu
    Zhai, Xiaodan
    Bai, Yu
    Liu, Cong
    Zhang, Le
    FRONTIERS IN ENDOCRINOLOGY, 2023, 14
  • [10] Satisfaction with continuous glucose monitoring is positively correlated with time in range in children with type 1 diabetes
    Marigliano, Marco
    Pertile, Riccardo
    Mozzillo, Enza
    Troncone, Alda
    Maffeis, Claudio
    Morotti, Elisa
    Di Candia, Francesca
    Fedi, Ludovica
    Iafusco, Dario
    Zanfardino, Angela
    Cauvin, Vittoria
    Maltoni, Giulio
    Zucchini, Stefano
    Cherubini, Valentino
    Tiberi, Valentina
    Minuto, Nicola
    Bassi, Marta
    Rabbone, Ivana
    Savastio, Silvia
    Tinti, Davide
    Tornese, Gianluca
    Schiaffini, Riccardo
    Passanisi, Stefano
    Lombardo, Fortunato
    Bonfanti, Riccardo
    Scaramuzza, Andrea
    Franceschi, Roberto
    DIABETES RESEARCH AND CLINICAL PRACTICE, 2023, 204