The Role of Intraoral Scanners in the Shade Matching Process: A Systematic Review

被引:30
作者
Akl, Mohammed A. [1 ]
Mansour, Dina E. [2 ]
Zheng, Fengyuan [1 ]
机构
[1] Univ Minnesota, Sch Dent, Dept Restorat Sci, Div Prosthodont, Minneapolis, MN 55455 USA
[2] Univ Minnesota, Sch Dent, Dept Restorat Sci, Div Endodont, Minneapolis, MN 55455 USA
来源
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY | 2023年 / 32卷 / 03期
关键词
Color science; digital dentistry; intraoral scanners; shade matching; shade selection; TOOTH-COLOR; IN-VIVO; RELIABILITY; REPEATABILITY;
D O I
10.1111/jopr.13576
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose The variation in findings with regards to the accuracy and precision of intraoral scanners for shade selection are no doubt confusing for clinicians who may find it difficult to make evidence-based decisions. The aim of this systematic review is to provide a comprehensive and in-depth assessment of available studies to determine the viability of using intraoral scanners for the purpose of shade matching. The PICO-guided research question is as follows: when shade matching, are intraoral scanners as valid as visual or other digital shade measuring devices in determining tooth colors. Methods Electronic databases including PubMed/MEDLINE, SCOPUS, EBSCO, Cochrane, and ProQuest were systematically searched for articles published between January 1, 2011 and December 30, 2021 using the main search terms: "intraoral scanners," "scanners," "TRIOS," "CEREC," "Planmeca," "Medit," "digital dentistry" in concurrence with one of the following keywords: "EasyShade" OR "shade selection" OR "shade matching" OR "shade" OR "tooth color" OR "tooth shade" OR "digital shade matching." Bibliographies of included articles and the following journals were searched for relevant articles: Journal of Prosthetic Dentistry, Journal of Prosthodontics, Journal of Esthetic and Restorative Dentistry, Journal of Advanced Prosthodontics, and Journal of Dentistry. A total of 15 articles were included in the review. Results Intraoral scanners are highly repeatable for shade matching, and outperformed visual shade matching. Accuracy varied significantly between studies, with the majority recommending the use of visual shade matching to confirm/verify the intraoral scanner results. Setting intraoral scanners to the Vita 3D Master shade guide improved both accuracy and precision. Shade matching with intraoral scanners may be influenced by external factors such as ambient light sources and incorrect use or manipulation. Conclusion Intraoral scanners set to the Vita 3D Master shade guide may be used for shade matching, but shade should be verified with visual shade matching. Further studies are required to address limitations of current studies.
引用
收藏
页码:196 / 203
页数:8
相关论文
共 45 条
[1]   Mathematical Tooth Proportions: A Systematic Review [J].
Akl, Mohammed A. ;
Mansour, Dina E. ;
Mays, Keith ;
Wee, Alvin G. .
JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2022, 31 (04) :289-298
[2]   Evaluation of self shade matching ability of dental students using visual and instrumental means [J].
AlSaleh, Samar ;
Labban, Manal ;
AlHariri, Morouj ;
Tashkandi, Esam .
JOURNAL OF DENTISTRY, 2012, 40 :E82-E87
[3]  
Bergman B, 1999, INT J PROSTHODONT, V12, P135
[4]   In vivo study for tooth colour determination-visual versus digital [J].
Brandt, Jan ;
Nelson, Shirley ;
Lauer, Hans-Christoph ;
von Hehn, Ulrike ;
Brandt, Silvia .
CLINICAL ORAL INVESTIGATIONS, 2017, 21 (09) :2863-2871
[5]   Application of a digital technique in evaluating the reliability of shade guides [J].
Cal, E ;
Sonugelen, M ;
Guneri, P ;
Kesercioglu, A ;
Kose, T .
JOURNAL OF ORAL REHABILITATION, 2004, 31 (05) :483-491
[6]  
Cao Y, 2020, Beijing Da Xue Xue Bao Yi Xue Ban, V52, P129
[7]  
Carter E.C., 2018, CIE 015:2018, V4th, DOI DOI 10.25039/TR.015.2018
[8]  
Chen H, 2012, QUINTESSENCE INT, V43, P649
[9]  
Culic C, 2018, Curr Health Sci J, V44, P337, DOI 10.12865/CHSJ.44.04.02
[10]   Comparing the effectiveness of shade measurement by intraoral scanner, digital spectrophotometer, and visual shade assessment [J].
Czigola, Alexandra ;
Roth, Ivett ;
Vitai, Viktoria ;
Feher, Dora ;
Hermann, Peter ;
Borbely, Judit .
JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2021, 33 (08) :1166-1174