Inter-rater and intra-rater reliability of manual assessment of respiratory motion in patients with unilateral cervical radiculopathy: A cross-sectional study

被引:0
|
作者
Yoosefinejad, Amin Kordi [1 ,2 ]
Yousefiyan, Raziyeh [3 ]
Nazari, Raziyeh [3 ]
Rezaei, Iman [1 ,2 ,4 ]
机构
[1] Shiraz Univ Med Sci, Sch Rehabil Sci, Phys Therapy Dept, 1 Abivardi Ave,Chamran Blvd, Shiraz 713451733, Iran
[2] Shiraz Univ Med Sci, Rehabil Sci Res Ctr, Shiraz, Iran
[3] Shiraz Univ Med Sci, Student Res Comm, Sch Rehabil Sci, Shiraz, Iran
[4] Shiraz Univ Med Sci, Sch Rehabil Sci, Phys Therapy Dept, 1 Abivardi Ave,Chamran Blvd, Shiraz 71345, Iran
关键词
Breathing pattern; Cervical radiculopathy; Manual assessment of respiratory motion; Reliability; HEMIDIAPHRAGMATIC PARALYSIS; SPONDYLOSIS; DYSPNEA;
D O I
10.1016/j.ijosm.2024.100708
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Altered breathing pattern is a consequence of dysfunctional breathing. The respiratory pattern might be impaired in patients with cervical radiculopathy due to the involvement of common nerve roots with the phrenic nerve (C3- C5). Objective: The aim of this study was to investigate the inter-rater and intra-rater reliability of a technique for evaluating the breathing pattern known as manual assessment of respiratory motion (MARM) in patients with unilateral cervical radiculopathy. Design: Cross-sectional study. Setting: Rehabilitation Sciences Research Center Participants: Twenty-five patients with unilateral cervical radiculopathy aged 30-55 years participated in this study. Methods: Two experienced physical therapists investigated the respiratory pattern of the patients during normal and deep breathing using MARM, separately. Assessments were repeated again a week apart by each examiner. The inter- and intra-rater reliability of the MARM were calculated. Results: "Very good" inter-rater and intra-rater reliability were found with the MARM values during both normal and deep breathing patterns. (Inter-rater: ICC range = 0.71 to 0.82; intra-rater: ICC range = 0.72 to 0.80). Conclusions: MARM is a reliable clinical and research tool for assessing breathing patterns with very good interand intra-rater reliability in patients with unilateral cervical radiculopathy.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Measuring Essay Assessment: Intra-rater and Inter-rater Reliability
    Kayapinar, Ulas
    EURASIAN JOURNAL OF EDUCATIONAL RESEARCH, 2014, (57): : 113 - 135
  • [2] Intra-rater and inter-rater reliability of pressure pain threshold assessment in stroke patients
    Zhang, Yong-Hui
    Wang, Yu-Chen
    Hu, Gong-Wei
    Ding, Xiao-Qin
    Shen, Xiao-Hua
    Ng, Hui Ya
    Rong, Ji-Feng
    Wang, Xue-Qiang
    EUROPEAN JOURNAL OF PHYSICAL AND REHABILITATION MEDICINE, 2022, 58 (04) : 549 - 557
  • [3] Intra-rater and inter-rater reliability of robotic arthrometer DYNEELAX®
    Mihalinec, Katja
    Martinez-Cepa, Carmen B.
    Zuil-Escobar, Juan C.
    Kejzar, Natasa
    Vauhnik, Renata
    JOURNAL OF EXPERIMENTAL ORTHOPAEDICS, 2024, 11 (03)
  • [4] THE INTER-RATER AND INTRA-RATER RELIABILITY ANALYSIS OF WORKPLACE ERGONOMIC RISK ASSESSMENT
    Rohani, Jafri Mohd.
    Adeyemi, Ademola James
    Abd Aziz, Roseni
    Rani, Mat Rebi Abdul
    JURNAL TEKNOLOGI, 2018, 80 (01): : 53 - 59
  • [5] Inter-rater and intra-rater reliability of nursing process records for patients with schizophrenia
    Chung, Min-Huey
    Chiang, I-Jen
    Chou, Kuei-Ru
    Chu, Hsin
    Chang, Hsiu-Ju
    JOURNAL OF CLINICAL NURSING, 2010, 19 (21-22) : 3023 - 3030
  • [6] Inter-rater and intra-rater reliability of Kinovea software for measurement of shoulder range of motion
    Reham M. Abd Elrahim
    Eman A. Embaby
    Mohamed F. Ali
    Ragia M. Kamel
    Bulletin of Faculty of Physical Therapy, 2016, 21 (2) : 80 - 87
  • [7] Inter-rater and intra-rater reliability of the current assessment model and tools for laparoscopic suturing
    Wei, Chin-Hung
    Shen, Shih-Chiang
    Duh, Yih-Cherng
    Tsai, Kuei-Yen
    Chen, Hsin-An
    Huang, Shih-Wei
    SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2022, 36 (09): : 6586 - 6591
  • [8] Inter-rater and intra-rater reliability of the current assessment model and tools for laparoscopic suturing
    Chin-Hung Wei
    Shih-Chiang Shen
    Yih-Cherng Duh
    Kuei‐Yen Tsai
    Hsin-An Chen
    Shih-Wei Huang
    Surgical Endoscopy, 2022, 36 : 6586 - 6591
  • [9] Optoelectronic plethysmography: Intra-rater and inter-rater reliability in healthy subjects
    Vieira, Danielle S. R.
    Hoffman, Mariana
    Pereira, Danielle A. G.
    Britto, Raquel R.
    Parreira, Veronica F.
    RESPIRATORY PHYSIOLOGY & NEUROBIOLOGY, 2013, 189 (03) : 473 - 476
  • [10] INTER-RATER AND INTRA-RATER RELIABILITY OF UROFLOWMETRY INTERPRETATION IN ADULT WOMEN
    Rickey, Leslie M.
    Mueller, Elizabeth R.
    Newman, Diane K.
    Markland, Alayne D.
    Falke, Chloe
    Rudser, Kyle
    Lukacz, Emily S.
    JOURNAL OF UROLOGY, 2023, 209 : E519 - E519