Experimental and CFD investigation of a helical coil heat exchanger coupled with a parabolic trough solar collector for heating a batch reactor: An exergy approach

被引:11
作者
Chater, Hamza [1 ]
Asbik, Mohamed [1 ]
Mouaky, Ammar [2 ]
Koukouch, Abdelghani [2 ]
Belandria, Veronica [3 ]
Sarh, Brahim [3 ]
机构
[1] Mohammed V Univ Rabat, ERTE, ENSAM, BP 6207,Ave FAR, Rabat 10100, Morocco
[2] Green Energy Pk IRESEN, UM6P, Km 2,Route Reg R206, Benguerir 43150, Morocco
[3] ICARE CNRS, 1C Ave Rech Sci, F-45071 Orleans 2, France
关键词
Exergy analysis; Entropy generation; Helical coil heat exchanger; Parabolic trough solar collector; Batch reactor; ENTROPY GENERATION; TUBE; PERFORMANCE; SIMULATION; STORAGE; FLOW;
D O I
10.1016/j.renene.2022.11.108
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
An experimental and numerical study was conducted to evaluate the performances of an innovative thermal system composed of a batch reactor surrounded by a helical coil heat exchanger (HX), coupled with a parabolic trough solar collector. It was equipped with K-type thermocouples connected to a laptop to instantaneously record the heat transfer fluid temperatures at the inlet and outlet of the HX. Temperature and pressure of water were also measured inside the reactor. It was found that all temperature profiles follow similar trends as the Direct Normal Irradiation (DNI) variation, and the thermal efficiency does not exceed 20% because of significant thermal losses. The exergy analysis was applied to the mathematically modeled HX and simulated using COMSOL Multiphysics software. Temperatures from the CFD simulation and those measured during experiment tests are in good agreement. The Bejan number varies rapidly from 0.6 to 1 because of the strong dominance of heat irreversibilities. The total entropy generation increases with temperature and DNI until reaching its maximum value, then decreases in the cooling phase. A new heat exchanger design was proposed and simulated to reduce thermal losses. Consequently, the destroyed exergy was considerably reduced, and the efficiency was enhanced by almost 16%.
引用
收藏
页码:1507 / 1519
页数:13
相关论文
共 30 条
[1]   Exergetic performance of the helically coiled tube heat exchangers: Comparison the sector-by-sector with tube in tube types [J].
Abu-Hamdeh, Nidal H. ;
Almitani, Khalid H. ;
Alimoradi, Ashkan .
ALEXANDRIA ENGINEERING JOURNAL, 2021, 60 (01) :979-993
[2]   Exergy analysis of Shell and helical coil heat exchanger and design optimization [J].
Al-Abbas, Audai Hussein ;
Mohammed, Akeel Abbas ;
Hassoon, Atheer Saleh .
HEAT AND MASS TRANSFER, 2021, 57 (05) :797-806
[3]  
[Anonymous], 2020, DESIGN OPERATION HEA, DOI [10.1016/C2017-0-03210-X, DOI 10.1016/C2017-0-03210-X]
[4]  
[Anonymous], 2011, Thermo-Fluid Dynamics of Two-Phase Flow, DOI [10.1007/978-1-4419-7985-8, DOI 10.1007/978-1-4419-7985-8]
[5]   Numerical study of laminar condensation of downward flowing vapour on a single horizontal cylinder or a bank of tubes [J].
Asbik, M ;
Daif, A ;
Panday, PK ;
Khmou, A .
CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 1999, 77 (01) :54-61
[6]   Exergy analysis of solar desalination still combined with heat storage system using phase change material (PCM) [J].
Asbik, Mohamed ;
Ansari, Omar ;
Bah, Abdellah ;
Zari, Nadia ;
Mimet, Abdelaziz ;
El-Ghetany, Hamdy .
DESALINATION, 2016, 381 :26-37
[7]   Exergy analysis of an integrated solar combined cycle system [J].
Baghernejad, A. ;
Yaghoubi, M. .
RENEWABLE ENERGY, 2010, 35 (10) :2157-2164
[8]  
Bejan A., 1999, THERMODYNAMIC OPTIMI, DOI [10.1007/978-94-011-4685-2, DOI 10.1007/978-94-011-4685-2, 10.1007/978-94- 011-4685-2]
[9]  
Bellout H., 2014, INCOMPRESSIBLE BIPOL, DOI [10.1007/978-3-319-00891-2, DOI 10.1007/978-3-319-00891-2]
[10]  
Chater H., 2021, 2021 9 INT RENEWABLE, P1, DOI [10.1109/IRSEC53969.2021.9741104, DOI 10.1109/IRSEC53969.2021.9741104]