Non-invasive imaging of neural activity with magnetic detection electrical impedance tomography (MDEIT): a modelling study

被引:7
作者
Mason, Kai [1 ]
Aristovich, Kirill [1 ]
Holder, David [1 ]
机构
[1] UCL, Dept Med Phys & Biomed Engn, Gower St, London, England
基金
英国工程与自然科学研究理事会;
关键词
impedance imaging; tomography; neural imaging; magnetometry; human; non-invasive; NEURONAL DEPOLARIZATION; EVOKED RESPONSES; HUMAN HEAD; EIT; RECONSTRUCTION; BRAIN; MAGNETOENCEPHALOGRAPHY; FIELD;
D O I
10.1088/1361-6579/ad0358
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Objectives. (1) Develop a computational pipeline for three-dimensional fast neural magnetic detection electrical impedance tomography (MDEIT), (2) determine whether constant current or constant voltage is preferable for MDEIT, (3) perform reconstructions of simulated neural activity in a human head model with realistic noise and compare MDEIT to EIT and (4) perform a two-dimensional study in a saline tank for MDEIT with optically pumped magnetometers (OPMs) and compare reconstruction algorithms. Approach. Forward modelling and image reconstruction were performed with a realistic model of a human head in three dimensions and at three noise levels for four perturbations representing neural activity. Images were compared using the error in the position and size of the reconstructed perturbations. Two-dimensional MDEIT was performed in a saline tank with a resistive perturbation and one OPM. Six reconstruction algorithms were compared using the error in the position and size of the reconstructed perturbations. Main results. A computational pipeline was developed in COMSOL Multiphysics, reducing the Jacobian calculation time from months to days. MDEIT reconstructed images with a lower reconstruction error than EIT with a mean difference of 7.0%, 5.5% and 11% for three noise cases representing current noise, reduced current source noise and reduced current source and magnetometer noise. A rank analysis concluded that the MDEIT Jacobian was less rank-deficient than the EIT Jacobian. Reconstructions of a phantom in a saline tank had a best reconstruction error of 13%, achieved using 0th-order Tikhonov regularisation with simulated noise-based correction. Significance. This study demonstrated that three-dimensional MDEIT for neural imaging is feasible and that MDEIT reconstructed superior images to EIT, which can be explained by the lesser rank deficiency of the MDEIT Jacobian. Reconstructions of a perturbation in a saline tank demonstrated a proof of principle for two-dimensional MDEIT with OPMs and identified the best reconstruction algorithm.
引用
收藏
页数:19
相关论文
共 50 条
[31]   Towards non-invasive imaging through spinal-cord generated magnetic fields [J].
Spedden, Meaghan E. ;
O'Neill, George C. ;
Tierney, Tim M. ;
West, Timothy O. ;
Schmidt, Maike ;
Mellor, Stephanie ;
Farmer, Simon F. ;
Bestmann, Sven ;
Barnes, Gareth R. .
FRONTIERS IN MEDICAL TECHNOLOGY, 2024, 6
[32]   Impedance changes recorded with scalp electrodes during visual evoked responses: Implications for Electrical Impedance Tomography of fast neural activity [J].
Gilad, O. ;
Holder, D. S. .
NEUROIMAGE, 2009, 47 (02) :514-522
[33]   Non-invasive detection of neuronal population activity in human hippocampus [J].
Tesche, CD ;
Karhu, J ;
Tissari, SO .
COGNITIVE BRAIN RESEARCH, 1996, 4 (01) :39-47
[34]   A non-invasive experiment for root zone monitoring using electrical resistivity imaging [J].
Pradipta, Arya ;
Kirmizakis, Panagiotis ;
Papadopoulos, Nikos ;
Soupios, Pantelis .
ENVIRONMENTAL EARTH SCIENCES, 2025, 84 (01)
[35]   Non-invasive temperature monitoring in fixed-bed reactors by electrical capacitance tomography [J].
Weiss, Michael ;
Fischerauer, Alice ;
Jess, Andreas ;
Fischerauer, Gerhard .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2024, 35 (09)
[36]   Magnetic resonance electrical impedance tomography (MREIT) for high-resolution conductivity imaging [J].
Woo, Eung Je ;
Seo, Jin Keun .
PHYSIOLOGICAL MEASUREMENT, 2008, 29 (10) :R1-R26
[37]   A Simulation Study on Induced Current Magnetic Resonance Electrical Impedance Tomography of Anisotropic Brain Tissues [J].
Liu, Yang ;
Dai, Songshi .
2010 3RD INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING AND INFORMATICS (BMEI 2010), VOLS 1-7, 2010, :75-77
[38]   Application of non-invasive cerebral electrical impedance measurement on brain edema in patients with cerebral infarction [J].
He, Lan Ying ;
Wang, Jian ;
Luo, Yong ;
Dong, Wei Wei ;
Liu, Li Xu .
NEUROLOGICAL RESEARCH, 2010, 32 (07) :770-774
[39]   Non-invasive urine volume estimation in the bladder by electrical impedance-based methods: A review [J].
Noyori, Shuhei S. ;
Nakagami, Gojiro ;
Sanada, Hiromi .
MEDICAL ENGINEERING & PHYSICS, 2022, 101
[40]   A novel method for recording neuronal depolarization with recording at 125-825 Hz: implications for imaging fast neural activity in the brain with electrical impedance tomography [J].
Oh, T. ;
Gilad, O. ;
Ghosh, A. ;
Schuettler, M. ;
Holder, D. S. .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2011, 49 (05) :593-604