Membrane distillation of wastewater: comparison of model and real organics

被引:3
作者
Habib, Rasikh [1 ]
Phuong, Mai [1 ]
Asif, Muhammad Bilal [2 ,3 ]
Jiang, Guangming [1 ]
Sivakumar, Muttucumaru [1 ]
机构
[1] Univ Wollongong, Fac Engn & Informat Sci, Sch Civil Min Environm & Architectural Engn, Wollongong, NSW 2525, Australia
[2] King Abdullah Univ Sci & Technol, Adv Membranes & Porous Mat Ctr, Thuwal 23955, Saudi Arabia
[3] King Abdullah Univ Sci andTechnol, Catalysis Ctr Phys Sci & Engn, Thuwal 23955, Saudi Arabia
关键词
direct contact membrane distillation (DCMD); effluent organic matter; humic acid; organic fouling mechanisms; sodium alginate; HUMIC-ACID; REMOVAL; PERFORMANCE; EFFICIENCY; REJECTION; RECOVERY; LAYER;
D O I
10.2166/wst.2024.045
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Fouling behaviour in membrane distillation (MD) processes plays a crucial role in determining their widespread acceptability. Most studies have primarily focused on model organic foulants, such as humic acid (HA) and sodium alginate (SA). This study investigates the fouling of a polytetrafluoroethylene membrane in a direct contact MD (DCMD) using model organics (i.e., HA and SA) and real wastewater. The results indicated that the flux decline (5-60%) was only observed during the initial phase of the operation with model organic foulants. In contrast, real wastewater caused a gradual decline in flux throughout the experiment in both the concentrate (40%) and continuous (90%) modes. The study also found significant differences in the fouling layer morphology, composition, and hydrophobicity between the model organic foulants and real wastewater. Fourier transform infrared spectroscopy findings demonstrated that the fouling layer formed by real wastewater varied significantly from model organics, which primarily comprised of protein-like and polysaccharide-like functional groups. Finally, liquid chromatography-organic carbon detection revealed that the fouling layer of the MD membrane with real wastewater was composed of 40.7% hydrophobic and 59.3% hydrophilic organics. This study suggests that model organics may not accurately reflect real wastewater fouling.
引用
收藏
页码:1325 / 1339
页数:15
相关论文
共 50 条
  • [21] Membrane distillation technology for treatment of wastewater from rubber industry in Malaysia
    Mokhtar, N. M.
    Lau, W. J.
    Ismail, A. F.
    Veerasamy, D.
    [J]. 12TH GLOBAL CONFERENCE ON SUSTAINABLE MANUFACTURING - EMERGING POTENTIALS, 2015, 26 : 792 - 796
  • [22] A novel osmosis membrane bioreactor-membrane distillation hybrid system for wastewater treatment and reuse
    Nguyen Cong Nguyen
    Hau Thi Nguyen
    Chen, Shiao-Shing
    Huu Hao Ngo
    Guo, Wenshan
    Chan, Wen Hao
    Ray, Saikat Sinha
    Li, Chi-Wang
    Hsu, Hung-Te
    [J]. BIORESOURCE TECHNOLOGY, 2016, 209 : 8 - 15
  • [23] Solar distillation meets the real world: a review of solar stills purifying real wastewater and seawater
    Arunkumar, Thirugnanasambantham
    Sathyamurthy, Ravishankar
    Denkenberger, David
    Lee, Sang Joon
    [J]. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2022, 29 (16) : 22860 - 22884
  • [24] Domestic wastewater treatment by forward osmosis-membrane distillation (FO-MD) integrated system
    Li, Jie
    Hou, Deyin
    Li, Kuiling
    Zhang, Yong
    Wang, Jun
    Zhang, Xiwang
    [J]. WATER SCIENCE AND TECHNOLOGY, 2018, 77 (06) : 1514 - 1523
  • [25] Performance and implications of forward osmosis-membrane distillation hybrid system for simultaneous treatment of different real produced water streams
    Nawaz, Muhammad Saqib
    Alamoudi, Talal
    Soukane, Sofiane
    Son, Hyuk Soo
    Jin, Yong
    Medina, Sandra C.
    Mustakeem, Mustakeem
    Gudideni, Veerabhadraiah
    Al-Qahtani, Ali
    Ghaffour, Noreddine
    [J]. CHEMICAL ENGINEERING JOURNAL, 2022, 450
  • [26] Comparison of different model solutions to simulate membrane fouling in the ultrafiltration of a secondary effluent from a municipal wastewater treatment plant
    Tora-Grau, M.
    Soler-Cabezas, J. L.
    Vincent-Vela, M. C.
    Mendoza-Roca, J. A.
    Martinez-Francisco, F. J.
    [J]. DESALINATION AND WATER TREATMENT, 2015, 55 (11) : 2924 - 2930
  • [27] Effect of surfactants on the treatment of radioactive laundry wastewater by direct contact membrane distillation
    Wen, Xia
    Li, Fuzhi
    Jiang, Bei
    Zhang, Xue
    Zhao, Xuan
    [J]. JOURNAL OF CHEMICAL TECHNOLOGY AND BIOTECHNOLOGY, 2018, 93 (08) : 2252 - 2261
  • [28] Boron Rejection from Aqueous Solution and Wastewater by Direct Contact Membrane Distillation
    Tan, Burcu
    Selengil, Ugur
    Bektas, Tijen Ennil
    [J]. 5TH EURASIAN WASTE MANAGEMENT SYMPOSIUM, EWMS 2020, 2020, : 533 - 542
  • [29] Membrane distillation as a second stage treatment of hydrothermal liquefaction wastewater after ultrafiltration
    Sayegh, Ali
    Prakash, Nikhil Shylaja
    Horn, Harald
    Saravia, Florencia
    [J]. SEPARATION AND PURIFICATION TECHNOLOGY, 2022, 285
  • [30] Organic Fouling Impact in a Direct Contact Membrane Distillation System Treating Wastewater: Experimental Observations and Modeling Approach
    Charfi, Amine
    Tibi, Fida
    Kim, Jeonghwan
    Hur, Jin
    Cho, Jinwoo
    [J]. MEMBRANES, 2021, 11 (07)