Optimizing Clinical Cardiac MRI Workflow through Single Breath-Hold Compressed Sensing Cine: An Evaluation of Feasibility and Efficiency

被引:2
作者
Wang, Fuyan [1 ]
Zhou, Junjie [1 ,2 ]
Pu, Cailing [1 ]
Yu, Feidan [1 ]
Wu, Yan [1 ]
Zhang, Lingjie [1 ]
Ma, Siying [1 ]
Hu, Hongjie [1 ]
机构
[1] Zhejiang Univ, Sir Run Run Shaw Hosp, Dept Radiol, Dept Dermatol,Sch Med, 3 East Qingchun Rd, Hangzhou 310016, Peoples R China
[2] Zhejiang Univ, Affiliated Hosp 4, Int Inst Med, Dept Radiol,Sch Med, 1 Shangcheng Ave, Yiwu 322000, Peoples R China
基金
中国国家自然科学基金;
关键词
cardiac magnetic resonance; compressed sensing; flip angle; examination workflow; RESOLUTION; VOLUMES;
D O I
10.3390/jcm13030753
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Although compressed sensing (CS) accelerated cine holds immense potential to replace conventional cardiovascular magnetic resonance (CMR) cine, how to use CS-based cine appropriately during clinical CMR examinations still needs exploring. Methods: A total of 104 patients (46.5 +/- 17.1 years) participated in this prospective study. For each participant, a balanced steady state free precession (bSSFP) cine was acquired as a reference, followed by two CS accelerated cine sequences with identical parameters before and after contrast injection. Lastly, a CS accelerated cine sequence with an increased flip angle was obtained. We subsequently compared scanning time, image quality, and biventricular function parameters between these sequences. Results: All CS cine sequences demonstrated significantly shorter acquisition times compared to bSSFP(ref )cine (p < 0.001). The bSSFP(ref) cine showed higher left ventricular ejection fraction (LVEF) than all CS cine sequences (all p < 0.001), but no significant differences in LVEF were observed among the three CS cine sequences. Additionally, CS cine sequences displayed superior global image quality (p < 0.05) and fewer artifacts than bSSFP(ref) cine (p < 0.005). Unenhanced CS cine and enhanced CS cine with increased flip angle showed higher global image quality than other cine sequences (p < 0.005). Conclusion: Single breath-hold CS cine delivers precise biventricular function parameters and offers a range of benefits including shorter scan time, better global image quality, and diminished motion artifacts. This innovative approach holds great promise in replacing conventional bSSFP cine and optimizing the CMR examination workflow.
引用
收藏
页数:12
相关论文
共 26 条
  • [1] Accelerated MRI for the assessment of cardiac function
    Axel, Leon
    Otazo, Ricardo
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2016, 89 (1063)
  • [2] European cardiovascular magnetic resonance (EuroCMR) registry - multi national results from 57 centers in 15 countries
    Bruder, Oliver
    Wagner, Anja
    Lombardi, Massimo
    Schwitter, Juerg
    van Rossum, Albert
    Pilz, Guenter
    Nothnagel, Detlev
    Steen, Henning
    Petersen, Steffen
    Nagel, Eike
    Prasad, Sanjay
    Schumm, Julia
    Greulich, Simon
    Cagnolo, Alessandro
    Monney, Pierre
    Deluigi, Christina C.
    Dill, Thorsten
    Frank, Herbert
    Sabin, Georg
    Schneider, Steffen
    Mahrholdt, Heiko
    [J]. JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2013, 15
  • [3] Feasibility of single-shot compressed sensing cine imaging for analysis of left ventricular function and strain in cardiac MRI
    Chen, Y.
    Qian, W.
    Liu, W.
    Zhu, Y.
    Zhou, X.
    Xu, Y.
    Zhu, X.
    [J]. CLINICAL RADIOLOGY, 2021, 76 (06) : 471.e1 - 471.e7
  • [4] Primer and Historical Review on Rapid Cardiac CINE MRI
    Curtis, Aaron D.
    Cheng, Hai-Ling M.
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2022, 55 (02) : 373 - 388
  • [5] Compressed sensing MRI of different organs: ready for clinical daily practice?
    Delattre, Benedicte Marie Anne
    Boudabbous, Sana
    Hansen, Catrina
    Neroladaki, Angeliki
    Hachulla, Anne-Lise
    Vargas, Maria Isabel
    [J]. EUROPEAN RADIOLOGY, 2020, 30 (01) : 308 - 319
  • [6] Compressed sensing cine imaging with high spatial or high temporal resolution for analysis of left ventricular function
    Goebel, Juliane
    Nensa, Felix
    Schemuth, Haemi P.
    Maderwald, Stefan
    Gratz, Marcel
    Quick, Harald H.
    Schlosser, Thomas
    Nassenstein, Kai
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2016, 44 (02) : 366 - 374
  • [7] Quality assessment of cardiovascular magnetic resonance in the setting of the European CMR registry: description and validation of standardized criteria
    Klinke, Vincenzo
    Muzzarelli, Stefano
    Lauriers, Nathalie
    Locca, Didier
    Vincenti, Gabriella
    Monney, Pierre
    Lu, Christian
    Nothnagel, Detlev
    Pilz, Guenter
    Lombardi, Massimo
    van Rossum, Albert C.
    Wagner, Anja
    Bruder, Oliver
    Mahrholdt, Heiko
    Schwitter, Juerg
    [J]. JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2013, 15
  • [8] Breath-hold and free-breathing quantitative assessment of biventricular volume and function using compressed SENSE: a clinical validation in children and young adults
    Kocaoglu, Murat
    Pednekar, Amol S.
    Wang, Hui
    Alsaied, Tarek
    Taylor, Michael D.
    Rattan, Mantosh S.
    [J]. JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2020, 22 (01)
  • [9] The effects of flip angle optimization on the precision and reproducibility of feature tracking derived strain assessment in contrast enhanced bSSFP cine images
    Kuetting, Daniel L. R.
    Feisst, Andreas
    Dabir, Darius
    Luetkens, Julian
    Homsi, Rami
    Thomas, Daniel
    Schild, Hans H.
    Sprinkart, Alois M.
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2018, 102 : 9 - 14
  • [10] SCMR Position Paper (2020) on clinical indications for cardiovascular magnetic resonance
    Leiner, Tim
    Bogaert, Jan
    Friedrich, Matthias G.
    Mohiaddin, Raad
    Muthurangu, Vivek
    Myerson, Saul
    Powell, Andrew J.
    Raman, Subha, V
    Pennell, Dudley J.
    [J]. JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2020, 22 (01)