Characterization and comparative evaluation of polysulfone and polypropylene hollow fiber membranes for blood oxygenators

被引:0
|
作者
Teber, Oguz Orhun [1 ,2 ]
Altinay, Aysegul Derya [1 ,3 ]
Naziri Mehrabani, Seyed Ali [1 ,2 ]
Zeytuncu, Bihter [1 ,4 ]
Ates-Genceli, Esra [3 ]
Dulekgurgen, Ebru [3 ]
Golcez, Tansu [5 ,6 ]
Yildiz, Yahya [7 ]
Pekkan, Kerem [8 ]
Koyuncu, Ismail [1 ,2 ,3 ]
机构
[1] Istanbul Tech Univ, Natl Res Ctr Membrane Technol, TR-34469 Istanbul, Turkiye
[2] Istanbul Tech Univ, Nano Sci & Nano Engn Dept, Istanbul, Turkiye
[3] Istanbul Tech Univ, Environm Engn Dept, Istanbul, Turkiye
[4] Istanbul Tech Univ, Dept Met & Mat Engn, Istanbul, Turkiye
[5] Koc Univ, Grad Sch Sci & Engn, Biomed Sci & Engn Dept, Istanbul, Turkiye
[6] Bogazici Univ, Inst Biomed Engn, Istanbul, Turkiye
[7] Istanbul Medipol Univ, Sch Med, Dept Anesthesiol & Reanimat, Istanbul, Turkiye
[8] Koc Univ, Mech Engn Dept, Istanbul, Turkiye
基金
欧洲研究理事会;
关键词
artificial lung; blood oxygenator; cardiovascular devices; polypropylene; polysulfone; MASS-TRANSFER; GAS TRANSFER; COMPATIBILITY;
D O I
10.1002/app.55121
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
Blood oxygenators are used to saturate oxygen levels and remove carbon dioxide from the body during cardiopulmonary bypass. Although the natural lung is hydrophilic, commercially used oxygenator materials are hydrophobic. Surface hydrophobicity weakens blood compatibility, as long-term contact with the blood environment may lead to different degrees of blood activity. Polysulfone may be considered an alternative hydrophilic material in the design of oxygenators. Therefore, it may be directed toward developing hydrophilic membranes. This study aims to investigate the feasibility of achieving blood gas transfer with a polysulfone-based microporous hollow fiber membrane and compare it with the commercially available polypropylene membranes. Structural differences in the membrane morphology, surface hydrophilicity, tortuosity, mass transfer rate, and material properties under different operation conditions of temperature and flow rates are reported. The polysulfone membrane has a water contact angle of 81.3 degrees, whereas a commercial polypropylene membrane is 94.5 degrees. The mass transfer resistances (s/m) for the polysulfone and polypropylene membranes are calculated to be 4.8 x 104 and 1.5 x 104 at 25 degrees C, respectively. The module made of polysulfone was placed in the cardiopulmonary bypass circuit in parallel with the commercial oxygenator, and pH, pO2, pCO2 levels, and metabolic activity were measured in blood samples. Preparation steps of the blood oxygenator.image
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Polypropylene hollow fiber oxygenators: Effect of the sorption of perfluoropolyethers
    Cassiola, F
    Kiyohara, PK
    Joekes, I
    ARTIFICIAL ORGANS, 2000, 24 (03) : 168 - 173
  • [2] Hydrophobization of Polysulfone Hollow Fiber Membranes
    A. V. Bildyukevich
    T. V. Plisko
    V. V. Usosky
    A. A. Ovcharova
    V. V. Volkov
    Petroleum Chemistry, 2018, 58 : 279 - 288
  • [3] Hydrophobization of Polysulfone Hollow Fiber Membranes
    Bildyukevich, A. V.
    Plisko, T. V.
    Usosky, V. V.
    Ovcharova, A. A.
    Volkov, V. V.
    PETROLEUM CHEMISTRY, 2018, 58 (04) : 279 - 288
  • [4] Microstructured Hollow Fiber Membranes: Potential Fiber Shapes for Extracorporeal Membrane Oxygenators
    Ecker, Paul
    Pekovits, Markus
    Yorov, Tsvetan
    Haddadi, Bahram
    Lukitsch, Benjamin
    Elenkov, Martin
    Janeczek, Christoph
    Jordan, Christian
    Gfoehler, Margit
    Harasek, Michael
    MEMBRANES, 2021, 11 (05)
  • [5] ASYMMETRIC POLYSULFONE HOLLOW FIBER MEMBRANES FOR GAS SEPARATION
    FRITZSCHE, AK
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1987, 193 : 11 - PMSE
  • [6] Preparation and Performance of Polysulfone Hollow Fiber Ultrafiltration Membranes
    Bai, Yang
    Liu, Zhen
    Sun, Daobao
    FRONTIERS OF MECHANICAL ENGINEERING AND MATERIALS ENGINEERING II, PTS 1 AND 2, 2014, 457-458 : 309 - 312
  • [7] Pectin coated hollow fiber polypropylene membranes
    Lewinska, D
    Piatkiewicz, W
    Rosinski, S
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1997, 20 (11): : 650 - 655
  • [8] COMPARATIVE CHARACTERIZATION OF HOLLOW FIBER MEMBRANES PRODUCED BY THE VISCOSE METHOD
    GENSRICH, J
    SCHOLZ, C
    HOLTZ, M
    MULLER, K
    PAUL, D
    CHEMISCHE TECHNIK, 1988, 40 (09): : 407 - 407
  • [9] Fabrication and characterization of superhydrophobic polypropylene hollow fiber membranes for carbon dioxide absorption
    Lv, Yuexia
    Yu, Xinhai
    Jia, Jingjing
    Tu, Shan-Tung
    Yan, Jinyue
    Dahlquist, Erik
    APPLIED ENERGY, 2012, 90 (01) : 167 - 174
  • [10] Prevention of the capillary contraction of polysulfone based hollow fiber membranes
    Bildyukevich, A. V.
    Usosky, V. V.
    PETROLEUM CHEMISTRY, 2014, 54 (08) : 652 - 658