Accounting for blood attenuation in intravascular near-infrared fluorescence-ultrasound imaging using a fluorophore-coated guidewire

被引:3
作者
Rauschendorfer, Philipp [1 ,2 ]
Wissmeyer, Georg [3 ]
Jaffer, Farouc A. [3 ,4 ]
Gorpas, Dimitris [1 ,2 ]
Ntziachristos, Vasilis [1 ,2 ,5 ]
机构
[1] Tech Univ Munich, Chair Biol Imaging Cent Inst Translat Canc Res Tr, Sch Med, Munich, Germany
[2] Helmholtz Zentrum Munchen, Inst Biol & Med Imaging, Neuherberg, Germany
[3] Massachusetts Gen Hosp, Cardiovasc Res Ctr, Cardiol Div, Boston, MA USA
[4] Massachusetts Gen Hosp, Wellman Ctr Photomed, Boston, MA USA
[5] DZHK German Ctr Cardiovasc Res, Munich Heart Alliance, Munich, Germany
关键词
intravascular imaging; near-infrared fluorescence imaging; intravascular ultrasound; quantification; light attenuation; ATHEROSCLEROSIS; INFLAMMATION; CATHETER; IVUS;
D O I
10.1117/1.JBO.28.4.046001
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Significance: Intravascular near-infrared fluorescence (NIRF) imaging aims to improve the inspection of vascular pathology using fluorescent agents with specificity to vascular disease biomarkers. The method has been developed to operate in tandem with an anatomical modality, such as intravascular ultrasound (IVUS), and complements anatomical readings with pathophysiological contrast, enhancing the information obtained from the hybrid examination.Aim: However, attenuation of NIRF signals by blood challenges NIRF quantification. We propose a new method for attenuation correction in NIRF intravascular imaging based on a fluorophore-coated guidewire that is used as a reference for the fluorescence measurement and provides a real-time measurement of blood attenuation during the NIRF examination.Approach: We examine the performance of the method in a porcine coronary artery ex vivo and phantoms using a 3.2F NIRF-IVUS catheter.Results: We demonstrate marked improvement over uncorrected signals of up to 4.5-fold and errors of <11% for target signals acquired at distances up to 1 mm from the catheter system employed.Conclusions: The method offers a potential means of improving the accuracy of intravascular NIRF imaging under in vivo conditions.
引用
收藏
页数:14
相关论文
共 26 条
[1]   Validating a bimodal intravascular ultrasound (IVUS) and near-infrared fluorescence (NIRF) catheter for atherosclerotic plaque detection in rabbits [J].
Abran, Maxime ;
Staehli, Barbara E. ;
Merlet, Nolwenn ;
Mihalache-Avram, Teodora ;
Mecteau, Melanie ;
Rheaume, Eric ;
Busseuil, David ;
Tardif, Jean-Claude ;
Lesage, Frederic .
BIOMEDICAL OPTICS EXPRESS, 2015, 6 (10) :3989-3999
[2]   Near-infrared fluorescent coatings of medical devices for image-guided surgery [J].
Ashoka, Anila Hoskere ;
Kong, Seong-Ho ;
Seeliger, Barbara ;
Andreiuk, Bohdan ;
Soares, Renato Vianna ;
Barberio, Manuel ;
Diana, Michele ;
Klymchenko, Andrey S. .
BIOMATERIALS, 2020, 261
[3]   Optoacoustic sensing of hematocrit to improve the accuracy of hybrid fluorescence-ultrasound intravascular imaging [J].
Bozhko, Dmitry ;
Karlas, Angelos ;
Gorpas, Dimitris ;
Ntziachristos, Vasilis .
JOURNAL OF BIOPHOTONICS, 2018, 11 (10)
[4]   Quantitative intravascular biological fluorescence-ultrasound imaging of coronary and peripheral arteries in vivo [J].
Bozhko, Dmitry ;
Osborn, Eric A. ;
Rosenthal, Amir ;
Verjans, Johan W. ;
Hara, Tetsuya ;
Kellnberger, Stephan ;
Wissmeyer, Georg ;
Ovsepian, Saak V. ;
McCarthy, Jason R. ;
Mauskapf, Adam ;
Stein, Ashley F. ;
Jaffer, Farouc A. ;
Ntziachristos, Vasilis .
EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2017, 18 (11) :1253-1261
[5]   Photophysical Properties of Indocyanine Green in the Shortwave Infrared Region [J].
Cosco, Emily D. ;
Lim, Irene ;
Sletten, Ellen M. .
CHEMPHOTOCHEM, 2021, 5 (08) :727-734
[6]   Intravascular near-infrared fluorescence catheter with ultrasound guidance and blood attenuation correction [J].
Dixon, Adam J. ;
Hossack, John A. .
JOURNAL OF BIOMEDICAL OPTICS, 2013, 18 (05)
[7]   Influence of oxygen saturation on the optical scattering properties of human red blood cells in the spectral range 250 to 2000 nm [J].
Friebel, Moritz ;
Helfmann, Juergen ;
Netz, Uwe ;
Meinke, Martina .
JOURNAL OF BIOMEDICAL OPTICS, 2009, 14 (03)
[8]   Influence of shear rate on the optical properties of human blood in the spectral range 250 to 1100 nm [J].
Friebel, Moritz ;
Helfmann, Juergen ;
Mueller, Gerhard ;
Meinke, Martina .
JOURNAL OF BIOMEDICAL OPTICS, 2007, 12 (05)
[9]   Image-Guided Surgery Using Invisible Near-Infrared Light: Fundamentals of Clinical Translation [J].
Gioux, Sylvain ;
Choi, Hak Soo ;
Frangioni, John V. .
MOLECULAR IMAGING, 2010, 9 (05) :237-255
[10]   Real-Time Catheter Molecular Sensing of Inflammation in Proteolytically Active Atherosclerosis [J].
Jaffer, Farouc A. ;
Vinegoni, Claudio ;
John, Michael C. ;
Aikawa, Elena ;
Gold, Herman K. ;
Finn, Aloke V. ;
Ntziachristos, Vasilis ;
Libby, Peter ;
Weissleder, Ralph .
CIRCULATION, 2008, 118 (18) :1802-1809