A Novel Electrochemiluminescence Immunosensor Based on Resonance Energy Transfer between g-CN and NU-1000(Zr) for Ultrasensitive Detection of Ochratoxin A in Coffee

被引:7
|
作者
Li, Linzhi [1 ]
Wang, Xiaofeng [2 ]
Chen, Jian [1 ]
Huang, Tianzeng [3 ]
Cao, Hongmei [1 ]
Liu, Xing [1 ]
机构
[1] Hainan Univ, Sch Food Sci & Engn, Haikou 570228, Peoples R China
[2] Nanjing Xiaozhuang Univ, Sch Environm Sci, Nanjing 211171, Peoples R China
[3] Hainan Univ, Sch Chem Engn & Technol, Haikou 570228, Peoples R China
基金
中国国家自然科学基金;
关键词
Nb28-C4bp alpha heptamer; electrochemiluminescence immunosensor; resonance energy transfer; ochratoxin A; METAL-ORGANIC FRAMEWORKS; CARBON NANOTUBES; APTASENSOR; G-C3N4; SIGNAL;
D O I
10.3390/foods12040707
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
In this study, an electrochemiluminescence (ECL) immunosensor based on nanobody heptamer and resonance energy transfer (RET) between g-C3N4 (g-CN) and NU-1000(Zr) was proposed for ultrasensitive ochratoxin A (OTA) detection. First, OTA heptamer fusion protein was prepared by fusing OTA-specific nanometric (Nb28) with a c-terminal fragment of C4 binding protein (C4bp alpha) (Nb28-C4bp alpha). Then, Nb28-C4bp alpha heptamer with the high affinity used as a molecular recognition probe, of which plenty of binding sites were provided for OTA-Apt-NU-1000(Zr) nanocomposites, thereby improving the immunosensors' sensitivity. In addition, the quantitative analysis of OTA can be achieved by using the signal quenching effect of NU-1000(Zr) on g-CN. As the concentration of OTA increases, the amount of OTA-Apt-NU-1000(Zr) fixed on the electrode surface decreases. RET between g-CN and NU-1000(Zr) is weakened leading to the increase of ECL signal. Thus, OTA content is indirectly proportional to ECL intensity. Based on the above principle, an ultra-sensitive and specific ECL immunosensor for OTA detection was constructed by using heptamer technology and RET between two nanomaterials, with a range from 0.1 pg/mL to 500 ng/mL, and the detection limit of only 33 fg/mL. The prepared ECL-RET immunosensor showed good performance and can be successfully used for the determination of OTA content in real coffee samples, suggesting that the nanobody polymerization strategy and the RET effect between NU-1000(Zr) and g-CN can provide an alternative for improving the sensitivity of important mycotoxin detection.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] A novel electrochemiluminescence resonance energy transfer system for ultrasensitive detection of prostate-specific antigen
    Deng, Li
    Chen, Hong-Yuan
    Xu, Jing-Juan
    ELECTROCHEMISTRY COMMUNICATIONS, 2015, 59 : 56 - 59
  • [2] A fluorescence immunosensor for ochratoxin A based on resonance energy transfer between fluorescein derivative and gold nanoparticles
    Serebrennikova, Kseniya, V
    Samokhvalov, Alexey, V
    Zherdev, Anatoly, V
    Dzantiev, Boris B.
    JOURNAL OF FOOD COMPOSITION AND ANALYSIS, 2022, 114
  • [3] Fluonanobody-based nanosensor via fluorescence resonance energy transfer for ultrasensitive detection of ochratoxin A
    Su, Benchao
    Zhang, Zhong
    Sun, Zhichang
    Tang, Zongwen
    Xie, Xiaoxia
    Chen, Qi
    Cao, Hongmei
    Yu, Xi
    Xu, Yang
    Liu, Xing
    Hammock, Bruce D.
    Journal of Hazardous Materials, 2022, 422
  • [4] Fluonanobody-based nanosensor via fluorescence resonance energy transfer for ultrasensitive detection of ochratoxin A
    Su, Benchao
    Zhang, Zhong
    Sun, Zhichang
    Tang, Zongwen
    Xie, Xiaoxia
    Chen, Qi
    Cao, Hongmei
    Yu, Xi
    Xu, Yang
    Liu, Xing
    Hammock, Bruce D.
    JOURNAL OF HAZARDOUS MATERIALS, 2022, 422
  • [5] Electrochemiluminescence immunosensor for cancer antigen 125 detection based on novel resonance energy transfer between graphitic carbon nitride and NIR CdTe/CdS QDs
    Gao, Hongmin
    Zhang, Ze
    Zhang, Yingcong
    Yu, Hongwei
    Rong, Shengzhong
    Meng, Lingqiang
    Song, Shizhen
    Mei, Yong
    Pan, Hongzhi
    Chang, Dong
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2021, 886
  • [6] Ultrasensitive electrochemiluminescence immunosensor for the detection of amyloid-β proteins based on resonance energy transfer between g-C3N4 and Pd NPs coated NH2-MIL-53
    Fang, Jinglong
    Zhao, Guanhui
    Dong, Xue
    Li, Xuan
    Miao, Juncong
    Wei, Qin
    Cao, Wei
    BIOSENSORS & BIOELECTRONICS, 2019, 142
  • [7] A novel "on-off-on" electrochemiluminescence aptasensor based on resonance energy transfer as signal amplification strategy for ultrasensitive detection of sulfadiazine in different samples
    Long, Youqi
    Liu, Junjie
    Wu, Yijie
    Fu, Lin
    Bai, Lijuan
    FOOD CHEMISTRY, 2024, 456
  • [8] A novel electrochemiluminescence immunoassay based on highly efficient resonance energy transfer for florfenicol detection
    Ma, Guoyu
    Wu, Panpian
    Wu, Kang
    Deng, Anping
    Li, Jianguo
    TALANTA, 2021, 235 (235)
  • [9] Novel "signal-on" electrochemiluminescence biosensor for the detection of PSA based on resonance energy transfer
    Wu, Mei-Sheng
    Chen, Ruo-Nan
    Xiao, Yao
    Lv, Zi-Xin
    TALANTA, 2016, 161 : 271 - 277
  • [10] A quenching electrochemiluminescence energy resonance transfer system based on CdS and COFs for the ultrasensitive detection of CA242
    Han, Baokun
    Wang, Shujun
    Xie, Fengqian
    Wang, Shuangna
    Tang, Feng
    Xiang, Shaowen
    Li, Yueyuan
    Wang, Ping
    Li, Yueyun
    Liu, Qing
    Liu, Yuying
    NEW JOURNAL OF CHEMISTRY, 2024, 48 (28) : 12733 - 12739