Comparison of an open view autorefractor with an open view aberrometer in determining peripheral refraction in children

被引:4
作者
Demir, Pelsin [1 ]
Macedo, Antonio Filipe [1 ,2 ]
Chakraborty, Ranjay [3 ,4 ]
Baskaran, Karthikeyan [1 ]
机构
[1] Linnaeus Univ, Dept Med & Optometry, Kalmar, Sweden
[2] Univ Minho, Ctr Phys Optometry & Vis Sci, Braga, Portugal
[3] Flinders Univ S Australia, Coll Nursing & Hlth Sci, Optometry & Vis Sci, Sturt North, GPO Box 2100, Adelaide, SA 5001, Australia
[4] Flinders Univ S Australia, Caring Futures Inst, GPO Box 2100, Adelaide, SA 5001, Australia
关键词
peripheral refraction; autorefraction; aberrometer; refractive error; schoolchildren; myopia; NIPPON SRW-5000 AUTOREFRACTOR; WAVE-FRONT SENSOR; CLINICAL-EVALUATION; AXIAL LENGTH; REPEATABILITY; ERROR; EYE; ABERRATIONS; MYOPIA; VALIDATION;
D O I
10.1016/j.optom.2021.12.002
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: The aim of this study was to compare central and peripheral refraction using an open view Shin-Nippon NVision-K 5001 autorefractor and an open view COAS-HD VR aberrometer in young children.Methods: Cycloplegic central and peripheral autorefraction was measured in the right eye of 123 children aged 8 to 16 years. Three measurements each were obtained with both Shin-Nippon NVision-K 5001 autorefractor and COAS-HD VR aberrometer along the horizontal visual field up to 30 degrees (nasal and temporal) in 10 degrees steps. The refraction from the autorefractor was compared with aberrometer refraction for pupil analysis diameters of 2.5-mm and 5.0-mm. Results: The Shin-Nippon was 0.30 D more hyperopic than COAS-HD VR at 2.5-mm pupil and 0.50 D more hyperopic than COAS-HD VR at 5-mm pupil for central refraction. For both pupil sizes, the 95% limits of agreement were approximately 0.50 D for central refraction, and limits were wider in the nasal visual field compared to the temporal visual field. The mean difference for both J0 and J45 were within 0.15 D and the 95% limits of agreement within 0.90 D across the horizontal visual field.Conclusion: Defocus components were similar between the Shin-Nippon autorefractor and the COAS-HD VR aberrometer with a 2.5-mm pupil for most visual field angles. However, there was a significant difference in defocus component between the Shin-Nippon autorefractor and the COAS-HD VR aberrometer with a 5.0-mm pupil, wherein the autorefractor measured more hyper-opia. The astigmatic components J0 and J45 were similar between instruments for both central and peripheral refraction.(c) 2021 Spanish General Council of Optometry. Published by Elsevier Espana, S.L.U. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
引用
收藏
页码:20 / 29
页数:10
相关论文
共 42 条
[1]   Improved wide-field emmetropic human eye model based on ocular wavefront measurements and geometry-independent gradient index lens [J].
Akram, M. Nadeem ;
Baraas, Rigmor C. ;
Baskaran, Karthikeyan .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2018, 35 (11) :1954-1967
[2]   The role of peripheral ocular length and peripheral corneal radius of curvature in determining refractive error [J].
Alhussain, Saleh H. A. ;
Mallen, Edward A. H. ;
Strang, Niall C. ;
Jonuscheit, Sven .
JOURNAL OF OPTOMETRY, 2022, 15 (02) :129-137
[3]  
Antonio FM, 2021, PROCSPIE
[4]   Comparison of peripheral refractions determined by different instruments [J].
Atchison, DA .
OPTOMETRY AND VISION SCIENCE, 2003, 80 (09) :655-660
[5]   Repeatability of autorefraction and axial length measurements after laser in situ keratomileusis [J].
Bailey, MD ;
Twa, MD ;
Mitchell, GL ;
Dhaliwal, DK ;
Jones, LA ;
McMahon, TT .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (05) :1025-1034
[6]  
Bakaraju Ravi C, 2015, J Optom, V8, P206, DOI 10.1016/j.optom.2015.01.005
[7]   Influence of Age on Peripheral Ocular Aberrations [J].
Baskaran, Karthikeyan ;
Unsbo, Peter ;
Gustafsson, Jorgen .
OPTOMETRY AND VISION SCIENCE, 2011, 88 (09) :1088-1098
[8]   Repeatability of Peripheral Aberrations in Young Emmetropes [J].
Baskaran, Karthikeyan ;
Theagarayan, Baskar ;
Carius, Staffan ;
Gustafsson, Jorgen .
OPTOMETRY AND VISION SCIENCE, 2010, 87 (10) :751-759
[9]   Validation of aberrometry-based relative peripheral refraction measurements [J].
Berntsen, David A. ;
Mutti, Donald O. ;
Zadnik, Karla .
OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2008, 28 (01) :83-90
[10]  
Chat SWS, 2001, OPHTHAL PHYSL OPT, V21, P87, DOI 10.1016/S0275-5408(00)00048-X