A method of real-time monitoring beam output stability of intense ion beam

被引:0
作者
Xu, Mo-Fei [1 ,2 ,3 ]
Xiang, Yu [1 ,2 ,3 ]
Zhang, Shi -Jian [1 ,2 ,3 ]
Remnev, Gennady Efimovich [1 ,4 ]
Le, Xiao-Yun [1 ,2 ,3 ]
机构
[1] Beihang Univ, Sch Phys, Beijing 100191, Peoples R China
[2] Beihang Univ, Beijing Adv Innovat Ctr Big Data Based Precis Med, Beijing 100191, Peoples R China
[3] Beihang Univ, Beijing Key Lab Adv Nucl Energy Mat & Phys, Beijing 100191, Peoples R China
[4] Natl Res Tomsk Polytech Univ, Tomsk 634050, Russia
基金
中国国家自然科学基金;
关键词
intense pulsed ion beam; beam output stability; real-time monitoring; pulsed X-ray diagnostic system; SURFACE; FUSION; IRRADIATION; WAVE;
D O I
10.7498/aps.72.20230854
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Intense pulsed ion beam (IPIB) technology has made remarkable progress in surface modification, mixing, polishing, film deposition, and nano powder synthesis in recent years. However, the surface properties of materials under IPIB irradiation are highly sensitive to beam intensity variations. Deviations from acceptable parameter range can change the surface characteristics and increase prevalence of defects. Consequently, the real-time online monitoring of beam stability during irradiation experiments and promptly identifying of pulses exhibiting significant parameter jitter are of significance in accurately analyzing results and optimizing surface modification. This study presents a fast-response pulse X-ray diagnostic system by employing EJ-200 plastic scintillator, 9266FLB photomultiplier tube, and Tektronic TDS 2024 four-channel oscilloscope. Single particle test demonstrates that the system achieves a time resolution of 6 ns, meeting the requirements for temporal response to detecting pulse X-ray signals with a half-width of similar to 80 ns. By adjusting the insulation magnetic field strength of the ion diode, the IPIB output level is regulated. The diagnostic system successfully captures X-rays emitted by the external magnetic insulated ion diode operating at different output levels. Simultaneously, the ion beam energy density is measured by using an infrared camera. To mitigate diagnostic errors stemming from target ablation, the maximum energy density is controlled to be below 1.32 J/cm(2). Analysis results establish a positive correlation between X-ray intensity and ion beam energy density. This relationship arises from the influence of the insulating magnetic field adjustment on the diode's operating voltage, which subsequently affects the bremsstrahlung radiant intensity and ion beam emission intensity. This correlation offers the potential for the real-time monitoring of IPIB beam output stability by utilizing X-ray signals. To further corroborate the synchronized changes in pulse X-ray intensity and ion beam intensity, Faraday cup is employed as an alternative to infrared imaging method for measuring ion current density. Results demonstrate that the amplitude of the X-ray signal changes synchronously with fluctuations of ion current density. It is worth noting that when the output intensity of ion beam deviates significantly (more than 10% of the preset value), the diagnostic system will respond quickly. These findings validate the efficacy of the proposed non-interceptive diagnostic method of real-time monitoring the intense pulsed ion beam output stability.
引用
收藏
页数:8
相关论文
共 40 条
  • [21] Time-resolved γ-spectrometer to promptly control number and energy of protons collectively accelerated as different bunches
    Ryzhkov, V. A.
    Pyatkov, I. N.
    Remnev, G. E.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2021, 998
  • [22] Crater formation on the surface of refractory alloys during high-power ion-beam processing
    Shuov, V. A.
    Novikov, A. S.
    Paikin, A. G.
    Belov, A. B.
    Lvov, A. F.
    Remnev, G. E.
    [J]. SURFACE & COATINGS TECHNOLOGY, 2007, 201 (19-20) : 8654 - 8658
  • [23] Sun H S, 1986, Nucl. Elec. and Det. Tech., V6, P112
  • [24] VANDEVENDER JP, 1986, PLASMA PHYS CONTR F, V28, P841, DOI 10.1088/0741-3335/28/6/001
  • [25] Influence of magnetic field of a radial focusing external magnetically insulated diode on emission behavior of intense pulsed ion beam
    Xu, Mofei
    Kuang, Shicheng
    Yu, Xiang
    Zhang, Shijian
    Yan, Sha
    Remnev, Gennady Efimovich
    Le, Xiaoyun
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2023, 537 : 38 - 45
  • [26] Microstructure Formation and Mechanical Properties of Metastable Titanium-Based Gradient Coating Fabricated via Intense Pulse Ion Beam Melt Mixing
    Xu, Mofei
    Yu, Xiang
    Zhang, Shijian
    Yan, Sha
    Tarbokov, Vladislav
    Remnev, Gennady
    Le, Xiaoyun
    [J]. MATERIALS, 2023, 16 (08)
  • [27] Study of metal film/substrate mixing by intense pulsed ion beam
    Yan, S.
    Le, X. Y.
    Zhao, W. J.
    Shang, Y. J.
    Wang, Yugang
    Xue, Jianming
    [J]. SURFACE & COATINGS TECHNOLOGY, 2007, 201 (9-11) : 4817 - 4821
  • [28] [杨海亮 Yang Hailiang], 2004, [原子能科学技术, Atomic Energy Science and Technology], V38, P204
  • [29] Preliminary research results for generation and application of high power ion beams on FLASH II accelerator
    Yang, HL
    Qiu, AC
    Zhang, JS
    He, XP
    Sun, JF
    Peng, JC
    Tang, JP
    Ren, SQ
    Ouyang, XP
    Zhang, GG
    Huang, JJ
    Yang, L
    Wang, HY
    Li, HY
    Li, JY
    [J]. ACTA PHYSICA SINICA, 2004, 53 (02) : 406 - 412
  • [30] Focusing of intense pulsed ion beam by magnetically insulated diode for material research
    Yu, Xiao
    Zhang, Shijian
    Stepanov, Andrey Vladimirovich
    Shamanin, Vitaly Igorevich
    Zhong, Haowen
    Liang, Guoying
    Xu, Mofei
    Zhang, Nan
    Kuang, Shicheng
    Ren, Jianhui
    Shang, Xuying
    Yan, Sha
    Remnev, Gennady Efimovich
    Le, Xiaoyun
    [J]. SURFACE & COATINGS TECHNOLOGY, 2020, 384