Lumbar discectomy and fusion: Organs? dose and effective dose estimation using Monte Carlo simulation

被引:0
作者
Metaxas, Vasileios [1 ]
Efthymiou, Fotios [1 ]
Dimitroukas, Christos [1 ,2 ]
Delis, Harry [1 ]
Gatzounis, George [3 ,4 ]
Zampakis, Petros [5 ,6 ]
Tzortzidis, Fotios [3 ]
Papadakos, Dimitrios [3 ]
Constantoyannis, Constantine [3 ,4 ]
Panayiotakis, George [1 ,2 ]
机构
[1] Univ Patras, Sch Med, Dept Med Phys, Patras 26504, Greece
[2] Univ Hosp Patras, Dept Med Phys, Patras 26504, Greece
[3] Univ Hosp Patras, Dept Neurosurg, Patras 26504, Greece
[4] Univ Patras, Sch Med, Dept Neurosurg, Patras 26504, Greece
[5] Univ Hosp Patras, Dept Radiol, Patras 26504, Greece
[6] Univ Patras, Sch Med, Dept Radiol, Patras 26504, Greece
关键词
Lumbar discectomy and fusion; Organ dose; Effective dose; VirtualDose-IR; RADIATION-EXPOSURE; PATIENT; REDUCTION; DOSIMETRY; RISKS;
D O I
10.1016/j.apradiso.2023.110781
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
In this study, the effect of patient- and procedure-related parameters on organs' dose (OD), peak skin dose (PSD) and effective dose (ED) during lumbar discectomy and fusion (LDF) was assessed. Intra-operative parameters obtained from 102 LDFs were inserted into VirtualDose-IR software implementing sex-specific and BMIadjustable anthropomorphic phantoms for dosimetric calculations. Fluoroscopy time (FT), kerma-area product (KAP), cumulative and incident air-kerma (Kair) were also recorded from the dosimetric report of the mobile Carm. An increase in KAP, Kair, PSD and ED was found for male or higher BMI patients, multi-level or fusion or L5/ S1 procedures. However, a significant difference was found only for PSD and incident Kair between normal and obese patients and for FT between discectomy and discectomy and fusion procedures. The spleen, kidneys and colon received the highest doses. The BMI have a significant impact only for kidneys, pancreas, and spleen doses when comparing obese to overweight and for urinary bladder when comparing overweight to normal patients. Multi-level and fusion procedures resulted in significantly higher doses for lungs, heart, stomach, adrenals, gallbladder and kidneys, while pancreas and spleen doses significantly increased only for multi-level procedures. Additionally, a significant increase was found only for urinary bladder, adrenals, kidneys, and spleen ODs when comparing L5/S1 and L3/L4 levels. The mean ODs were lower compared to the literature. These data may aid neurosurgeons in optimising exposure techniques during LDF to keep patients' dose as low as is practicably possible.
引用
收藏
页数:10
相关论文
共 50 条
  • [31] DOSE POINT KERNEL SIMULATION FOR MONOENERGETIC ELECTRONS AND RADIONUCLIDES USING MONTE CARLO TECHNIQUES
    Wu, J.
    Liu, Y. L.
    Chang, S. J.
    Chao, M. M.
    Tsai, S. Y.
    Huang, D. E.
    RADIATION PROTECTION DOSIMETRY, 2012, 152 (1-3) : 119 - 124
  • [32] Monte Carlo Estimation of Cerenkov Dose for Photo-Dynamic Radiotherapy
    Chibani, O.
    Eldib, A.
    Price, R.
    Mora, G.
    Ma, C.
    MEDICAL PHYSICS, 2014, 41 (06) : 278 - +
  • [33] Estimation of dose to a bystander from F-18 FDG patients using Monte Carlo simulation in clinical exposure scenarios
    Samaranayake, K. W. N. S.
    Mckay, Erin
    Hennessy, Thomas
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2025, : 359 - 367
  • [34] DOSIS: a Monte Carlo simulation program for dose related studies in mammography
    Delis, H
    Spyrou, G
    Panayiotakis, G
    Tzanakos, G
    EUROPEAN JOURNAL OF RADIOLOGY, 2005, 54 (03) : 371 - 376
  • [35] Organs' absorbed dose and comparison of different methods for effective dose calculation in computed tomography of parathyroid glands
    Dimitroukas, Christos P.
    Metaxas, Vasileios, I
    Efthymiou, Fotios O.
    Zampakis, Petros E.
    Kalogeropoulou, Christina P.
    Panayiotakis, George S.
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2022, 8 (05)
  • [36] A dose point kernel database using GATE Monte Carlo simulation toolkit for nuclear medicine applications: Comparison with other Monte Carlo codes
    Papadimitroulas, Panagiotis
    Loudos, George
    Nikiforidis, George C.
    Kagadis, George C.
    MEDICAL PHYSICS, 2012, 39 (08) : 5238 - 5247
  • [37] Effective dose estimation in cone-beam computed tomography for dental use by Monte-Carlo simulation optimizing calculation numbers using a step-and-shoot method
    Ozaki, Yoshihiro
    Watanabe, Hiroshi
    Kurabayashi, Tohru
    DENTOMAXILLOFACIAL RADIOLOGY, 2021, 50 (07)
  • [38] Dose to Organs Outside of CT Scan Range-Monte Carlo and Hybrid Phantom Approach
    Pelletier, C.
    Lee, C.
    Jung, J.
    Kim, J.
    Lee, C.
    MEDICAL PHYSICS, 2014, 41 (06) : 249 - 249
  • [39] Dose distributions in tubing irradiated by electron beam: Monte Carlo simulation and measurement
    Weiss, DE
    Johnson, WC
    Kensek, RP
    RADIATION PHYSICS AND CHEMISTRY, 1997, 50 (05): : 475 - 485
  • [40] INVESTIGATION OF A PRACTICAL PATIENT DOSE INDEX FOR ASSESSMENT OF PATIENT ORGAN DOSE FROM CONE-BEAM COMPUTED TOMOGRAPHY IN RADIATION THERAPY USING A MONTE CARLO SIMULATION
    Kamezawa, H.
    Arimura, H.
    Arakawa, H.
    Kameda, N.
    RADIATION PROTECTION DOSIMETRY, 2018, 181 (04) : 333 - 342