Lumbar discectomy and fusion: Organs? dose and effective dose estimation using Monte Carlo simulation

被引:0
|
作者
Metaxas, Vasileios [1 ]
Efthymiou, Fotios [1 ]
Dimitroukas, Christos [1 ,2 ]
Delis, Harry [1 ]
Gatzounis, George [3 ,4 ]
Zampakis, Petros [5 ,6 ]
Tzortzidis, Fotios [3 ]
Papadakos, Dimitrios [3 ]
Constantoyannis, Constantine [3 ,4 ]
Panayiotakis, George [1 ,2 ]
机构
[1] Univ Patras, Sch Med, Dept Med Phys, Patras 26504, Greece
[2] Univ Hosp Patras, Dept Med Phys, Patras 26504, Greece
[3] Univ Hosp Patras, Dept Neurosurg, Patras 26504, Greece
[4] Univ Patras, Sch Med, Dept Neurosurg, Patras 26504, Greece
[5] Univ Hosp Patras, Dept Radiol, Patras 26504, Greece
[6] Univ Patras, Sch Med, Dept Radiol, Patras 26504, Greece
关键词
Lumbar discectomy and fusion; Organ dose; Effective dose; VirtualDose-IR; RADIATION-EXPOSURE; PATIENT; REDUCTION; DOSIMETRY; RISKS;
D O I
10.1016/j.apradiso.2023.110781
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
In this study, the effect of patient- and procedure-related parameters on organs' dose (OD), peak skin dose (PSD) and effective dose (ED) during lumbar discectomy and fusion (LDF) was assessed. Intra-operative parameters obtained from 102 LDFs were inserted into VirtualDose-IR software implementing sex-specific and BMIadjustable anthropomorphic phantoms for dosimetric calculations. Fluoroscopy time (FT), kerma-area product (KAP), cumulative and incident air-kerma (Kair) were also recorded from the dosimetric report of the mobile Carm. An increase in KAP, Kair, PSD and ED was found for male or higher BMI patients, multi-level or fusion or L5/ S1 procedures. However, a significant difference was found only for PSD and incident Kair between normal and obese patients and for FT between discectomy and discectomy and fusion procedures. The spleen, kidneys and colon received the highest doses. The BMI have a significant impact only for kidneys, pancreas, and spleen doses when comparing obese to overweight and for urinary bladder when comparing overweight to normal patients. Multi-level and fusion procedures resulted in significantly higher doses for lungs, heart, stomach, adrenals, gallbladder and kidneys, while pancreas and spleen doses significantly increased only for multi-level procedures. Additionally, a significant increase was found only for urinary bladder, adrenals, kidneys, and spleen ODs when comparing L5/S1 and L3/L4 levels. The mean ODs were lower compared to the literature. These data may aid neurosurgeons in optimising exposure techniques during LDF to keep patients' dose as low as is practicably possible.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Fetal Organ Dose Assessment during Chest CT Examination Using Monte Carlo/Gate Simulation
    Benameur, Y.
    Tahiri, M.
    Mkimel, M.
    El Baydaoui, R.
    El Hariri, B.
    Mesradi, M. R.
    Hilali, A.
    Saad, E.
    PHYSICS OF PARTICLES AND NUCLEI LETTERS, 2023, 20 (04) : 690 - 698
  • [22] ORGAN DOSE EVALUATIONS BASED ON MONTE CARLO SIMULATION FOR CT EXAMINATIONS USING TUBE CURRENT MODULATION
    Fujii, K.
    Nomura, K.
    Muramatsu, Y.
    Obara, S.
    Akahane, K.
    Kusumoto, M.
    RADIATION PROTECTION DOSIMETRY, 2017, 174 (03) : 387 - 394
  • [23] PATIENT SIZE INDICES AND DOSE IN FLUOROSCOPICALLY GUIDED LUMBAR DISCECTOMY AND FUSION: A PRELIMINARY STUDY
    Metaxas, Vasileios, I
    Gatzounis, George D.
    Tzortzidis, Fotios N.
    Panayiotakis, George S.
    RADIATION PROTECTION DOSIMETRY, 2020, 192 (03) : 350 - 361
  • [24] DO THE BMI AND SURGEON INFLUENCE THE PATIENT DOSE IN FLUOROSCOPICALLY GUIDED LUMBAR DISCECTOMY AND FUSION?
    Metaxas, Vasileios, I
    Messaris, Gerasimos A.
    Gatzounis, George D.
    Tzortzidis, Fotios N.
    Panayiotakis, George S.
    RADIATION PROTECTION DOSIMETRY, 2019, 185 (04) : 472 - 482
  • [25] Radiation dose assessement on dual and 16 slices MDCT using Monte Carlo simulation
    Mkimel, M.
    Mesradi, M. R.
    El Baydaoui, R.
    Toufique, Y.
    Halimi, A.
    Hilal, M.
    Saad, E.
    Hilali, A.
    2018 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS (MEMEA), 2018, : 885 - 889
  • [26] Evaluation of glandular dose in mammography in presence of breast cysts using Monte Carlo simulation
    Deevband, Mohammad Reza
    Kaveh, Zeinab
    Ghorbani, Mahdi
    Khajetash, Benyamin
    POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING, 2021, 27 (01): : 41 - 50
  • [27] Scatter radiation dose profile evaluation in computed tomography using Monte Carlo simulation
    Mohammadi, Gh R. Fallah
    Hesamnezhad, L.
    Mahdavi, M.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2021, 19 (04): : 813 - 818
  • [28] DOSE COEFFICIENTS FOR LIVER CHEMOEMBOLISATION PROCEDURES USING MONTE CARLO CODE
    Karavasilis, E.
    Dimitriadis, A.
    Gonis, H.
    Pappas, P.
    Georgiou, E.
    Yakoumakis, E.
    RADIATION PROTECTION DOSIMETRY, 2016, 172 (04) : 409 - 415
  • [29] STOCHASTIC VARIABILITY IN EFFECTIVE DOSE TISSUE WEIGHTING FACTORS - A MONTE-CARLO STUDY
    LESLIE, WD
    HEALTH PHYSICS, 1994, 67 (01): : 70 - 75
  • [30] The effect of overranging on patient effective dose and organs' doses during parathyroid CT examinations utilising Monte Carlo software
    Dimitroukas, Christos P.
    Metaxas, Vasileios I.
    Efthymiou, Fotios O.
    Kalogeropoulou, Christina P.
    Zampakis, Petros E.
    Panayiotakis, George S.
    RADIATION PHYSICS AND CHEMISTRY, 2023, 212