Utility of the continuous intraoperative neuromonitoring in the prevention of the recurrent laryngeal nerve paralysis during thyroid surgery. A prospective observational study

被引:1
|
作者
Senosiain, Irene Maya [1 ]
Urdiain, Andrea Goikoetxea [1 ]
Egea, Maria Pilar Salvador [1 ]
Garayoa, Patricia Ahechu [1 ]
Apinaniz, Emma Anda [1 ]
Saiz, Isabel Blanco [2 ]
Montes, Raquel Lacomba [1 ]
机构
[1] Complejo Hosp Navarra, Endocrine Surg Unit, Pamplona, Spain
[2] Complejo Hosp Navarra, Nucl Med Dept, Pamplona, Spain
来源
CIRUGIA ESPANOLA | 2023年 / 101卷 / 07期
关键词
Continuous intraoperative; neuromonitoring; Recurrent laryngeal nerve; Vocal cord paralysis; Thyroid surgery; EMG CHANGES; INTERMITTENT; PALSY; METAANALYSIS; IMPACT;
D O I
10.1016/j.ciresp.2022.06.006
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: The continuous intraoperative neuromonitoring (C-IONM) of the recurrent laryngeal nerve (RLN) could help reducing the incidence of nerve paralysis after thyroid surgery, in comparison with the mere anatomical visualization of the RLN. The objective is to assess the efficacy and utility of C-IONM as a predictive test for recurrent laryngeal nerve paralysis after thyroidectomy. Methods: A prospective observational study was performed in 248 patients who underwent thyroid surgery where C-IONM was applied, between September 2018 and December 2019, in a high-volume center. A previous and later laryngoscopy was performed, which allowed to evaluate the reliability of the C-IONM as a predictive test for recurrent paralysis. Sensitivity (SE), specificity (SP), positive predictive value (PPV), negative predictive value (NPV) were studied. Results: A total number of 171 thyroidectomies, 62 hemithyroidectomies, 15 totalization thyroidectomies and 27 thyroidectomy with cervical dissections were performed. Postoperative laryngoscopy was altered in 40 patients (16.12%). The SE, SP, PPV and NPV values were 65%, 94.7%, 70.2% and 93.4% respectively. Conclusions: C-IONM is a safe technique that provides real-time information about anatomical and functional integrity of the RLN and can improve the results of thyroid surgery. (c) 2022 Published by Elsevier Espana, S.L.U. on behalf of AEC.
引用
收藏
页码:466 / 471
页数:6
相关论文
共 50 条
  • [41] Does the Use of Intraoperative Neuromonitoring during Thyroid and Parathyroid Surgery Reduce the Incidence of Recurrent Laryngeal Nerve Injuries? A Systematic Review and Meta-Analysis
    Saxe, Andrew
    Idris, Mohamed
    Gemechu, Jickssa
    DIAGNOSTICS, 2024, 14 (09)
  • [42] Meta-analysis of recurrent laryngeal nerve injury in thyroid surgery with or without intraoperative nerve monitoring
    Rulli, F.
    Ambrogi, V.
    Dionigi, G.
    Amirhassankhani, S.
    Mineo, T. C.
    Ottaviani, F.
    Buemi, A.
    Di Stefano, P.
    Mourad, M.
    ACTA OTORHINOLARYNGOLOGICA ITALICA, 2014, 34 (04) : 223 - 229
  • [43] Intraoperative monitoring of the recurrent laryngeal nerve during thyroid surgery in childhood
    Meyer, T.
    Timmermann, W.
    Hamelmann, W.
    MONATSSCHRIFT KINDERHEILKUNDE, 2006, 154 (08) : 817 - 821
  • [44] Immediate Intraoperative Repair of the Recurrent Laryngeal Nerve in Thyroid Surgery
    Simo, Ricard
    Nixon, Iain J.
    Rovira, Aleix
    Vander Poorten, Vincent
    Sanabria, Alvaro
    Zafereo, Mark
    Hartl, Dana M.
    Kowalski, Luiz P.
    Randolph, Gregory W.
    Kamani, Dipti
    Shaha, Ashok R.
    Shah, Jatin
    Marie, Jean-Paul
    Rinaldo, Alessandra
    Ferlito, Alfio
    LARYNGOSCOPE, 2021, 131 (06) : 1429 - 1435
  • [45] Traction injury of the recurrent laryngeal nerve: Results of continuous intraoperative neuromonitoring in a swine model
    Lee, Hye Yoon
    Cho, Young Geon
    You, Ji Young
    Choi, Byoung Ho
    Kim, Joon Yub
    Wu, Che-Wei
    Chiang, Feng-Yu
    Kim, Hoon Yub
    HEAD AND NECK-JOURNAL FOR THE SCIENCES AND SPECIALTIES OF THE HEAD AND NECK, 2016, 38 (04): : 582 - 588
  • [46] Electromyographic endotracheal tube placement during thyroid surgery in neuromonitoring of recurrent laryngeal nerve
    Tsai, Cheng-Jing
    Tseng, Kuang-Yi
    Wang, Fu-Yuan
    Lu, I-Cheng
    Wang, Hsun-Mo
    Wu, Che-Wei
    Chiang, Hui-Ching
    Chiang, Feng-Yu
    KAOHSIUNG JOURNAL OF MEDICAL SCIENCES, 2011, 27 (03) : 96 - 101
  • [47] Intraoperative Monitoring of the Recurrent Laryngeal Nerve in Thyroid Surgery
    H. Dralle
    C. Sekulla
    K. Lorenz
    M. Brauckhoff
    A. Machens
    World Journal of Surgery, 2008, 32 : 1358 - 1366
  • [48] Does extensive dissection of recurrent laryngeal nerve during thyroid operation increase the risk of nerve injury? Evidence from the application of intraoperative neuromonitoring
    Chiang, Feng-Yu
    Lu, I-Cheng
    Tsai, Cheng-Jing
    Hsiao, Pi-Jung
    Hsu, Chia-Cjen
    Wu, Che-Wei
    AMERICAN JOURNAL OF OTOLARYNGOLOGY, 2011, 32 (06) : 499 - 503
  • [49] Application of Intraoperative Neuromonitoring (IONM) of the Recurrent Laryngeal Nerve during Esophagectomy: A Systematic Review and Meta-Analysis
    Chen, Boyang
    Yang, Tianbao
    Wang, Wu
    Tang, Weifeng
    Xie, Jinbiao
    Kang, Mingqiang
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (02)
  • [50] Paralysis of the recurrent laryngeal nerve after thyroid surgery - causes and consequences
    Thermann, M
    Feltkamp, M
    Elies, W
    Windhorst, T
    CHIRURG, 1998, 69 (09): : 951 - 956