Mid-term Results of Revision Total Hip Arthroplasty Using Delta Ceramic-on-Ceramic

被引:5
作者
Lee, Young-Kyun [1 ,2 ]
Ha, Yong-Chan [1 ,3 ]
Won, Samuel Jaeyoon [1 ]
Kim, Jin-Hak [1 ,3 ]
Park, Jung-Wee [1 ]
Koo, Kyung-Hoi [1 ,2 ]
机构
[1] Seoul Natl Univ, Dept Orthoped Surg, Bundang Hosp, 166 Gumi Ro, Seongnam 13620, South Korea
[2] Seoul Natl Univ, Dept Orthoped Surg, Coll Med, Seoul, South Korea
[3] Chung Ang Univ Hosp, Dept Orthopaed Surg, Seoul, South Korea
关键词
Revision hip arthroplasty; Delta ceramic; Complication; Survivorship; CLASSIFICATION; ABNORMALITIES; SQUEAKING; FIXATION;
D O I
10.4055/cios21192
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Delta ceramic-on-ceramic (CoC) articulation affords excellent outcomes in primary total hip arthroplasty (THA). However, the safety and reliability of this bearing in revision THA need more evidence. This study aimed to report complications, radiological changes, clinical results, and survivorship of revision THA using Delta CoC articulation at minimum 5-year follow-up.Methods: We reviewed 118 revision THAs (113 patients: 68 men and 45 women) performed with use of Delta CoC bearing. Their mean age was 58.7 years (range, 30-90 years) and their mean body mass index was 24.6 kg/m2 (range, 15.2-32.5 kg/m2). These patients were followed up for 5-12 years (mean, 7.2 years). We evaluated squeak, grinding sensation, ceramic fracture, disloca-tion, periprosthetic joint infection (PJI), periprosthetic fracture, prosthetic loosening, ceramic wear, osteolysis, modified Harris hip score (mHHS), and survivorship with any reoperation after the revision as the endpoint.Results: Two patients (1.7%) had grinding sensation, but no patient had ceramic fracture. Reoperations were necessary in 9 hips (7.6%) due to PJIs in 2, stem loosening in 2, cup loosening in 2, recurrent dislocation in 2, and periprosthetic fracture in 1. No hip had measurable wear or osteolysis. The average mHHS improved from 53.3 points before the revision to 82.3 points at the final follow-up. Survivorship was 91.6% (95% confidence interval, 86.3%-96.9%) at 12 years.Conclusions: The Delta ceramic bearing appeared a reliable option for revision THA, showing encouraging mid-term results with acceptable survivorship and a low complication rate.
引用
收藏
页码:20 / 26
页数:7
相关论文
共 28 条
[1]   Prospective analysis of hip arthroscopy with 2-year follow-up [J].
Byrd, JWT ;
Jones, KS .
ARTHROSCOPY, 2000, 16 (06) :578-587
[2]   Delta-on-Delta Ceramic Bearing Surfaces in Revision Hip Arthroplasty [J].
Castagnini, Francesco ;
Bordini, Barbara ;
Tassinari, Enrico ;
Stea, Susanna ;
Ancarani, Cristina ;
Traina, Francesco .
JOURNAL OF ARTHROPLASTY, 2019, 34 (09) :2065-2071
[3]   Midterm outcome of fourth-generation ceramic-on-ceramic bearing surface in revision total hip arthroplasty [J].
Chang, Jun-Dong ;
Kim, In-Sung ;
Mansukhani, Sameer Ajit ;
Sharma, Vishwas ;
Lee, Sang-Soo ;
Yoo, Je-Hyun .
JOURNAL OF ORTHOPAEDIC SURGERY, 2018, 26 (02)
[4]  
DANTONIO J, 1993, CLIN ORTHOP RELAT R, P133
[5]  
DANTONIO JA, 1989, CLIN ORTHOP RELAT R, P126
[6]  
DELEE JG, 1976, CLIN ORTHOP RELAT R, P20
[7]  
ENGH CA, 1994, CLIN ORTHOP RELAT R, P89
[8]  
ENGH CA, 1990, CLIN ORTHOP RELAT R, P107
[9]   CEMENTLESS ACETABULAR COMPONENTS [J].
ENGH, CA ;
GRIFFIN, WL ;
MARX, CL .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1990, 72 (01) :53-59
[10]  
GRUEN TA, 1979, CLIN ORTHOP RELAT R, P17