A spatial mapping of thermal comfort and air quality (SMTC-AQ) framework for the built environment using computational fluid dynamics approach

被引:5
作者
Rajput, Tripti Singh [1 ]
Thomas, Albert [1 ]
机构
[1] Indian Inst Technol Bombay Powai, Dept Civil Engn, Mumbai 400076, India
关键词
SMTC-AQ; IEQ; Thermal comfort; IAQ; Opening characteristics; DRIVEN NATURAL VENTILATION; INDOOR ENVIRONMENT; CLIMATE; PERFORMANCE; SUMMER; INDIA; AGE; BUILDINGS;
D O I
10.1016/j.jobe.2023.108267
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Indoor environmental quality (IEQ), driven by thermal comfort and indoor air quality (IAQ), is a major factor that impacts occupant's well-being and productivity since people spend 80-90 % of their time indoors. The current approaches for assessing and quantifying IEQ presume fixed values and ranges in naturally ventilated (NV) spaces within the simulation environment. However, such an approach cannot capture point-to-point changes that occur in the built environment due to localized variations of environmental variables such as air velocity and temperature. This study proposes a sensing and simulation-based framework, Spatial Mapping of Thermal Comfort and Air Quality (SMTC-AQ) in a computational fluid dynamics (CFD) environment to address this. Salient characteristics of SMTC-AQ include the modification of predicted mean vote (PMV) for NV spaces, specifically for the Indian context, and the implementation of the under-explored concept of domain-decoupling utilizing the ISHRAE weather file. Using SMTC-AQ, the study determines the optimal window-to-wall ratio (WWR) and opening-to-wall ratio (OWR) for a case study room in an Indian academic building, considering both IAQ and thermal comfort. In the study, indoor air velocity and temperature are first validated with field data, followed by a scenario analysis to assess the impact of opening characteristics on IEQ. The findings show that for building spaces in tropical climates with moderate outdoor temperatures and lower relative humidity, thermal comfort, and IAQ can be improved by implementing higher WWR and OWR. Moreover, WWR is a more relevant criterion for improving thermal comfort and a better OWR design is crucial for enhancing IAQ in NV spaces.
引用
收藏
页数:25
相关论文
共 84 条
[61]  
RMC Mumbai, Mumbai Regional Meteorological Centre
[62]   Indoor air quality and health in schools: A critical review for developing the roadmap for the future school environment [J].
Sadrizadeh, Sasan ;
Yao, Runming ;
Yuan, Feng ;
Awbi, Hazim ;
Bahnfleth, William ;
Bi, Yang ;
Cao, Guangyu ;
Croitoru, Cristiana ;
de Dear, Richard ;
Haghighat, Fariborz ;
Kumar, Prashant ;
Malayeri, Mojtaba ;
Nasiri, Fuzhan ;
Ruud, Mathilde ;
Sadeghian, Parastoo ;
Wargocki, Pawel ;
Xiong, Jing ;
Yu, Wei ;
Li, Baizhan .
JOURNAL OF BUILDING ENGINEERING, 2022, 57
[63]   Indoor Air Quality Monitoring Systems Based on Internet of Things: A Systematic Review [J].
Saini, Jagriti ;
Dutta, Maitreyee ;
Marques, Goncalo .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2020, 17 (14) :1-22
[64]   Improved indoor environment through optimised ventilator and furniture positioning: A case of slum rehabilitation housing, Mumbai, India [J].
Sarkar, Ahana ;
Bardhan, Ronita .
FRONTIERS OF ARCHITECTURAL RESEARCH, 2020, 9 (02) :350-369
[65]   TROPICAL SUMMER INDEX - A STUDY OF THERMAL COMFORT OF INDIAN SUBJECTS [J].
SHARMA, MR ;
ALI, S .
BUILDING AND ENVIRONMENT, 1986, 21 (01) :11-24
[66]   High-performance building: Sensitivity analysis for simulating different combinations of components of a two-sided windcatcher [J].
Sheikhshahrokhdehkordi, Mohammadamin ;
Khalesi, Javad ;
Goudarzi, Navid .
JOURNAL OF BUILDING ENGINEERING, 2020, 28
[67]   Status of thermal comfort in naturally ventilated classrooms during the summer season in the composite climate of India [J].
Singh, Manoj Kumar ;
Kumar, Sanjay ;
Ooka, Ryozo ;
Rijal, Hom B. ;
Gupta, Gyanesh ;
Kumar, Anuj .
BUILDING AND ENVIRONMENT, 2018, 128 :287-304
[68]   Adaptive thermal comfort in the offices of North-East India in autumn season [J].
Singh, Manoj Kumar ;
Ooka, Ryozo ;
Rijal, Hom B. ;
Takasu, Marina .
BUILDING AND ENVIRONMENT, 2017, 124 :14-30
[69]   Adaptive thermal comfort model for different climatic zones of North-East India [J].
Singh, Manoj Kumar ;
Mahapatra, Sadhan ;
Atreya, S. K. .
APPLIED ENERGY, 2011, 88 (07) :2420-2428
[70]   Optimizing passive design strategies for energy efficient buildings using hybrid artificial neural network (ANN) and multi-objective evolutionary algorithm through a case study approach [J].
Singh Rajput, Tripti ;
Thomas, Albert .
INTERNATIONAL JOURNAL OF CONSTRUCTION MANAGEMENT, 2023, 23 (13) :2320-2332