Non-invasive biochemical analysis and comparison of atopic dermatitis and psoriasis skin using handheld confocal Raman spectroscopy

被引:5
|
作者
Dinish, U. S. [1 ,7 ]
Yew, Yik Weng [2 ,3 ]
Vinod Ram, Keertana [1 ]
Bi, Renzhe [1 ]
Attia, Amalina Binte Ebrahim [4 ]
Teo Xinhui, Valerie [1 ]
Rajarahm, Poongkulali [1 ]
Oon, Hazel Hweeboon [5 ,6 ]
Thng, Steven Tien Guan [2 ,8 ]
Olivo, Malini [1 ,7 ]
机构
[1] ASTAR, Inst Mat Res & Engn IMRE, Singapore, Singapore
[2] Natl Skin Ctr, Singapore, Singapore
[3] Nanyang Technol Univ, Lee Kong Chian Sch Med, Singapore, Singapore
[4] ASTAR, Biomed Res Council BMRC, Singapore, Singapore
[5] Natl Skin Ctr, Singapore, Singapore
[6] Skin Res Inst Singapore SRIS, Singapore, Singapore
[7] ASTAR, Inst Mat Res & Engn IMRE, 2 Fusionopolis Way,Innovis 08-03, Singapore 138634, Singapore
[8] Natl Skin Ctr, Singapore 308205, Singapore
关键词
atopic dermatitis; ceramides; cholesterol; confocal Raman spectroscopy; psoriasis; skin diseases; water; OPTICAL COHERENCE TOMOGRAPHY; TRANSEPIDERMAL WATER-LOSS; STRATUM-CORNEUM LIPIDS; BARRIER FUNCTION; CERAMIDE COMPOSITION; CHOLESTEROL; MICROSCOPY; MICROSPECTROSCOPY; INFLAMMATION; PARAMETERS;
D O I
10.1002/jbio.202300191
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A handheld non-invasive confocal Raman system (CRS) was used to evaluate the differences in skin biochemicals between atopic dermatitis (AD) and psoriasis, which are inflammatory skin conditions. Raman spectral measurements in the fingerprint and high wavenumber region were acquired using a portable in-house CRS system with excitation lasers operating at 671 and 785 nm. It was deduced that relative amount of water decreases in the following sequence of skin: healthy, psoriasis and AD. Moreover, differential trends were observed for the subclasses of ceramides such that ceramide 3 is lower in the lesional AD and psoriasis skin as compared to healthy, while ceramide 2 showed a contrasting trend of decrease in lesional AD and increase in lesional psoriasis as opposed to healthy skin. Amount of cholesterol was significantly higher in lesional psoriasis as compared to lesional AD and healthy skin. These differences can aid in an objective classification of the skin conditions and in the formulation of new disease-specific topical treatments.
引用
收藏
页数:10
相关论文
共 29 条
  • [21] Non-invasive optical biopsy of skin lesions by multimodal system with OCT, ultrasound, photoacoustics and Raman spectroscopy
    Kukk, Anatoly Fedorov
    Wu, Di
    Panzer, Ruediger
    Emmert, Steffen
    Roth, Bernhard
    MULTIMODAL BIOMEDICAL IMAGING XIX, 2024, 12834
  • [22] Systematic Investigation of the Effect of Non-Ionic Emulsifiers on Skin by Confocal Raman Spectroscopy-A Comprehensive Lipid Analysis
    Liu, Yali
    Lunter, Dominique Jasmin
    PHARMACEUTICS, 2020, 12 (03)
  • [23] Assessment of Raman spectroscopy as a fast and non-invasive method for total stratum corneum thickness determination of pig skin
    Mahrhauser, Denise-Silvia
    Nagelreiter, Corinna
    Gehrig, Sebastian
    Geyer, Antonia
    Ogris, Manfred
    Kwizda, Kristina
    Valenta, Claudia
    INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2015, 495 (01) : 482 - 484
  • [24] Rapid, non-invasive screening of keratitis based on Raman spectroscopy combined with multivariate statistical analysis
    Xie, Xiaodong
    Chen, Cheng
    Sun, Tiantian
    Mamati, Gulinur
    Wan, Xinjuan
    Zhang, Wenjuan
    Gao, Rui
    Chen, Fangfang
    Wu, Wei
    Fan, Yangyang
    Lv, Xiaoyi
    Wu, Guohua
    PHOTODIAGNOSIS AND PHOTODYNAMIC THERAPY, 2020, 31
  • [25] Raman spectroscopy in biomedicine - non-invasive in vitro analysis of cells and extracellular matrix components in tissues
    Brauchle, Eva
    Schenke-Layland, Katja
    BIOTECHNOLOGY JOURNAL, 2013, 8 (03) : 288 - 297
  • [26] Raman microspectroscopy as a diagnostic tool for the non-invasive analysis of fibrillin-1 deficiency in the skin and in the in vitro skin models
    Brauchle, Eva
    Bauer, Hannah
    Fernes, Patrick
    Zuk, Alexandra
    Schenke-Layland, Katja
    Sengle, Gerhard
    ACTA BIOMATERIALIA, 2017, 52 : 41 - 48
  • [27] Non-invasive depth profiling of the stratum corneum in vivo using confocal Raman microscopy considering the non-homogeneous distribution of keratin
    Darvin, Maxim E.
    Choe, Chun-Sik
    Schleusener, Johannes
    Lademann, Juergen
    BIOMEDICAL OPTICS EXPRESS, 2019, 10 (06) : 3092 - 3103
  • [28] A Comparison of Non-destructive and Non-invasive material depth profiling using FT-Raman fiber optics and microspectroscopy
    Schultz, CP
    Jackson, RS
    SUBSURFACE SENSING TECHNOLOGIES AND APPLICATIONS II, 2000, 4129 : 284 - 293
  • [29] Establishment of an atopic dermatitis-like skin model in a hairless mouse by repeated elicitation of contact hypersensitivity that enables to conduct functional analyses of the stratum corneum with various non-invasive biophysical instruments
    Matsumoto, K
    Mizukoshi, K
    Oyobikawa, M
    Ohshima, H
    Tagami, H
    SKIN RESEARCH AND TECHNOLOGY, 2004, 10 (02) : 122 - 129