Reproducibility of deep learning based scleral spur localisation and anterior chamber angle measurements from anterior segment optical coherence tomography images

被引:18
作者
Liu, Peng [1 ,2 ,3 ]
Higashita, Risa [3 ,4 ]
Guo, Philip Yawen [5 ]
Okamoto, Keiichiro [4 ]
Li, Fei [6 ]
Nguyen, Anwell [7 ]
Sakata, Rei [8 ]
Duan, Lixin [1 ,2 ]
Aihara, Makoto [8 ]
Lin, Shan [7 ,9 ]
Zhang, Xiulan [6 ]
Leung, Christopher Kai-Shun [5 ]
Liu, Jiang [3 ,10 ,11 ,12 ]
机构
[1] Univ Elect Sci & Technol China, Sch Comp Sci & Engn, Chengdu, Peoples R China
[2] Univ Elect Sci & Technol China, Shenzhen Inst Adv Study, Chengdu, Peoples R China
[3] Southern Univ Sci & Technol, Dept Comp Sci & Engn, Shenzhen, Peoples R China
[4] Tomey Corp, Nagoya, Aichi, Japan
[5] Chinese Univ Hong Kong, Dept Ophthalmol & Visual Sci, Hong Kong, Peoples R China
[6] Sun Yat Sen Univ, Zhongshan Ophthalm Ctr, State Key Lab Ophthalmol, Guangzhou, Peoples R China
[7] Univ Calif San Francisco, Dept Ophthalmol, San Francisco, CA 94143 USA
[8] Univ Tokyo, Dept Ophthalmol, Tokyo, Japan
[9] Glaucoma Ctr San Francisco, San Francisco, CA USA
[10] Chinese Acad Sci, Cixi Inst Biomed Engn, Ningbo, Peoples R China
[11] Southern Univ Sci & Technol, Res Inst Trustworthy Autonomous Syst, Shenzhen, Peoples R China
[12] Southern Univ Sci & Technol, Dept Comp Sci & Engn, Guangdong Prov Key Lab Brain Inspired Intelligent, Shenzhen, Peoples R China
关键词
anterior chamber; glaucoma; CLASSIFICATION; GLAUCOMA; PREVALENCE;
D O I
10.1136/bjophthalmol-2021-319798
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Aims To apply a deep learning model for automatic localisation of the scleral spur (SS) in anterior segment optical coherence tomography (AS-OCT) images and compare the reproducibility of anterior chamber angle (ACA) width between deep learning located SS (DLLSS) and manually plotted SS (MPSS). Methods In this multicentre, cross-sectional study, a test dataset comprising 5166 AS-OCT images from 287 eyes (116 healthy eyes with open angles and 171 eyes with primary angle-closure disease (PACD)) of 287 subjects were recruited from four ophthalmology clinics. Each eye was imaged twice by a swept-source AS-OCT (CASIA2, Tomey, Nagoya, Japan) in the same visit and one eye of each patient was randomly selected for measurements of ACA. The agreement between DLLSS and MPSS was assessed using the Euclidean distance (ED). The angle opening distance (AOD) of 750 mu m (AOD750) and trabecular-iris space area (TISA) of 750 mu m (TISA750) were calculated using the CASIA2 embedded software. The repeatability of ACA width was measured. Results The mean age was 60.8 +/- 12.3 years (range: 30-85 years) for the normal group and 63.4 +/- 10.6 years (range: 40-91 years) for the PACD group. The mean difference in ED for SS localisation between DLLSS and MPSS was 66.50 +/- 20.54 mu m and 84.78 +/- 28.33 mu m for the normal group and the PACD group, respectively. The span of 95% limits of agreement between DLLSS and MPSS was 0.064 mm for AOD750 and 0.034 mm(2) for TISA750. The respective repeatability coefficients of AOD750 and TISA750 were 0.049 mm and 0.026 mm(2) for DLLSS, and 0.058 mm and 0.030 mm(2) for MPSS. Conclusion DLLSS achieved comparable repeatability compared with MPSS for measurement of ACA.
引用
收藏
页码:802 / 808
页数:7
相关论文
共 20 条
  • [1] Chan PPM, 2020, INVEST OPHTH VIS SCI, V61
  • [2] DeepLab: Semantic Image Segmentation with Deep Convolutional Nets, Atrous Convolution, and Fully Connected CRFs
    Chen, Liang-Chieh
    Papandreou, George
    Kokkinos, Iasonas
    Murphy, Kevin
    Yuille, Alan L.
    [J]. IEEE TRANSACTIONS ON PATTERN ANALYSIS AND MACHINE INTELLIGENCE, 2018, 40 (04) : 834 - 848
  • [3] Reproducibility of Scleral Spur Identification and Angle Measurements Using Fourier Domain Anterior Segment Optical Coherence Tomography
    Cumba, Ricardo J.
    Radhakrishnan, Sunita
    Bell, Nicholas P.
    Nagi, Kundandeep S.
    Chuang, Alice Z.
    Lin, Shan C.
    Mankiewicz, Kimberly A.
    Feldman, Robert M.
    [J]. JOURNAL OF OPHTHALMOLOGY, 2012, 2012
  • [4] The definition and classification of glaucoma in prevalence surveys
    Foster, PJ
    Buhrmann, R
    Quigley, HA
    Johnson, GJ
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2002, 86 (02) : 238 - 242
  • [5] AGE challenge: Angle Closure Glaucoma Evaluation in Anterior Segment Optical Coherence Tomography
    Fu, Huazhu
    Li, Fei
    Sun, Xu
    Cao, Xingxing
    Liao, Jingan
    Orlando, Jose Ignacio
    Tao, Xing
    Li, Yuexiang
    Zhang, Shihao
    Tan, Mingkui
    Yuan, Chenglang
    Bian, Cheng
    Xie, Ruitao
    Li, Jiongcheng
    Li, Xiaomeng
    Wang, Jing
    Geng, Le
    Li, Panming
    Hao, Huaying
    Liu, Jiang
    Kong, Yan
    Ren, Yongyong
    Bogunovic, Hrvoje
    Zhang, Xiulan
    Xu, Yanwu
    Zhang, Yichi
    Li, Nuhui
    Yang, Chunman
    Luo, Huang
    Li, Xingyi
    Deng, Feiyan
    Sun, Yi
    Zhou, Rouxi
    [J]. MEDICAL IMAGE ANALYSIS, 2020, 66
  • [6] A Deep Learning System for Automated Angle-Closure Detection in Anterior Segment Optical Coherence Tomography Images
    Fu, Huazhu
    Baskaran, Mani
    Xu, Yanwu
    Lin, Stephen
    Wong, Damon Wing Kee
    Liu, Jiang
    Tun, Tin A.
    Mahesh, Meenakshi
    Perera, Shamira A.
    Aung, Tin
    [J]. AMERICAN JOURNAL OF OPHTHALMOLOGY, 2019, 203 : 37 - 45
  • [7] Angle-Closure Detection in Anterior Segment OCT Based on Multilevel Deep Network
    Fu, Huazhu
    Xu, Yanwu
    Lin, Stephen
    Wong, Damon Wing Kee
    Baskaran, Mani
    Mahesh, Meenakshi
    Aung, Tin
    Liu, Jiang
    [J]. IEEE TRANSACTIONS ON CYBERNETICS, 2020, 50 (07) : 3358 - 3366
  • [8] Hao HY, 2019, IEEE ENG MED BIO, P849, DOI [10.1109/EMBC.2019.8857615, 10.1109/embc.2019.8857615]
  • [9] He K., 2016, 2016 IEEE C COMP VIS, DOI [DOI 10.1109/CVPR.2016.90, 10.1109/CVPR.2016.90]
  • [10] Stacked Hourglass Networks for Human Pose Estimation
    Newell, Alejandro
    Yang, Kaiyu
    Deng, Jia
    [J]. COMPUTER VISION - ECCV 2016, PT VIII, 2016, 9912 : 483 - 499