Synthetic cathinones determination by liquid chromatography-mass spectrometry after ultrasound membrane assisted extraction

被引:2
|
作者
Suarez-Oubina, Cristian [1 ]
Cabarcos-Fernandez, Pamela [2 ]
Tabernero-Duque, Maria Jesus [2 ]
Bermejo-Barrera, Pilar [1 ]
Moreda-Pineiro, Antonio [1 ]
Bermejo-Barrera, Ana Maria [2 ]
机构
[1] Univ Santiago de Compostela, Inst Mat iMATUS, Fac Chem, Dept Analyt Chem Nutr & Bromatol,Trace Element Sp, Ave Ciencias,S-N, Santiago De Compostela 15782, Spain
[2] Univ Santiago de Compostela, Forens Sci Inst Luis Concheiro INCIFOR, Fac Med, Rua San Francisco S-N, Santiago De Compostela 15782, Spain
关键词
Synthetic cathinones; Urine; LC-MS; MS; Ultrasounds; Membrane assisted solvent extraction; SOLVENT-EXTRACTION; POLYCHLORINATED-BIPHENYLS; URINE; BLOOD; QUANTIFICATION; METABOLITES; STIMULANTS; DRUGS; ABUSE; MS;
D O I
10.1016/j.microc.2023.108869
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The extraction time for membrane-assisted solvent extraction (MASE) when isolating synthetic cathinones from urine has been speeded up to 30 min by using ultrasounds. Separation and determination of eleven synthetic cathinones was further performed liquid chromatography-tandem mass spectrometry (LC-MS/MS). The ultra-sound assisted MASE consisted of adjusting 5.0 mL of urine at pH 11.8 and performing the extractive process with 400 mu L of n-hexane as an acceptor phase inside the polypropylene membrane under ultrasonication at room temperature. Synthetic cathinones exhibiting LogP values higher than 2.0, such as 3,4-dimethyl methcathinone, methylendioxypyrovalerone, and naphyrone), were efficiently extracted and pre-concentrated. Other synthetic cathinones (LogP between 2.0 and 0.7) were found to exhibit a lower mass transfer. The method was found to be matrix dependent, and a matrix-matched calibration was required for measurements. The achieved limits of detection (LOD) were between 0.03 (flephedrone) to 0.29 (ethylone) mu g L-1, with relative standard deviations (RSDs) within the 6-14% and 7-19% ranges for intraday and inter-day assays, and intraday and inter-day analytical recoveries from 84 to 115% and 85 to 118%, respectively. The developed method was finally applied to urine samples from volunteers attending a music festival.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Determination of Synthetic Cathinones in Urine Using Gas Chromatography-Mass Spectrometry Techniques
    Hong, Wei-Yin
    Ko, Ya-Chun
    Lin, Mei-Chih
    Wang, Po-Yu
    Chen, Yu-Pen
    Chiueh, Lih-Ching
    Shih, Daniel Yang-Chih
    Chou, Hsiu-Kuan
    Cheng, Hwei-Fang
    JOURNAL OF ANALYTICAL TOXICOLOGY, 2016, 40 (01) : 12 - 16
  • [2] Ultrasound assisted membrane-assisted solvent extraction for the determination of antidepressants in pericardial fluid by gas chromatography-mass spectrometry
    Cabarcos-Fernandez, P.
    Gesia, L.
    Moreda-Pineiro, A.
    Fernandez-Liste, A.
    Alvarez-Freire, I.
    Tabernero-Duque, M. J.
    Bermejo-Barrera, A. M.
    MICROCHEMICAL JOURNAL, 2025, 208
  • [3] Determination of Pesticide Residues in Ectoparasiticide-Impregnated Collars Using Ultrasound-Assisted Extraction and Liquid Chromatography-Mass Spectrometry
    Gomes, Pricilia Santos Pereira
    Santos, Luis Fabricio Santana
    Navickiene, Sandro
    BIOMEDICAL CHROMATOGRAPHY, 2025, 39 (03)
  • [4] Comparison of six derivatizing agents for the determination of nine synthetic cathinones using gas chromatography-mass spectrometry
    Alsenedi, Khalid A.
    Morrison, Calum
    ANALYTICAL METHODS, 2017, 9 (18) : 2732 - 2743
  • [5] Ultrasound-assisted dispersive liquid-liquid microextraction for the determination of synthetic musk fragrances in aqueous matrices by gas chromatography-mass spectrometry
    Homem, Vera
    Alves, Alice
    Alves, Arminda
    Santos, Lucia
    TALANTA, 2016, 148 : 84 - 93
  • [6] Determination of synthetic polycyclic musks in aqueous samples by ultrasound-assisted dispersive liquid-liquid microextraction and gas chromatography-mass spectrometry
    Yang, Ching-Ya
    Ding, Wang-Hsien
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 402 (04) : 1723 - 1730
  • [7] Determination of Synthetic Musks in Water by Ultrasound-assisted Emulsion Microextraction-Gas Chromatography-Mass Spectrometry
    Yu Rui-Peng
    Che Jin-Shui
    He En-Qi
    Niu Wei-Min
    Song Qi-Jun
    Wang Li-Ping
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2012, 40 (01) : 159 - 163
  • [8] Electrochemical profiling and liquid chromatography-mass spectrometry characterization of synthetic cathinones: From methodology to detection in forensic samples
    Schram, Jonas
    Parrilla, Marc
    Sleegers, Nick
    Van Durme, Filip
    van den Berg, Jorrit
    van Nuijs, Alexander L. N.
    De Wael, Karolien
    DRUG TESTING AND ANALYSIS, 2021, 13 (07) : 1282 - 1294
  • [9] Determination of Phthalates in Milk by Ultrasound-Assisted Dispersive Liquid-Liquid Microextraction and Gas Chromatography-Mass Spectrometry
    Tuncel, Semra G.
    Senlik, Damla
    ANALYTICAL LETTERS, 2016, 49 (09) : 1334 - 1343
  • [10] Confirmatory and quantitative analysis using experimental design for the extraction and liquid chromatography-UV, liquid chromatography-mass spectrometry and liquid chromatography-mass spectrometry/mass spectrometry determination of quinolones in turkey muscle
    Clemente, M.
    Hermo, M. P.
    Barron, D.
    Barbosa, J.
    JOURNAL OF CHROMATOGRAPHY A, 2006, 1135 (02) : 170 - 178