Intra- and inter-rater reliability in ultrasonographic measurements of coracohumeral distance

被引:0
作者
Guerra-Rodriguez, Diego [1 ]
Guerrero-Henriquez, Juan [2 ,3 ,7 ]
Basilio, Daniel [4 ]
Mendez-Rebolledo, Guillermo [5 ,6 ]
机构
[1] Univ Antofagasta, Fac Hlth Sci, Biomed Dept, Antofagasta, Chile
[2] Univ Antofagasta, Fac Hlth Sci, Rehabil & Human Movement Sci Dept, Antofagasta, Chile
[3] Univ Antofagasta, Fac Ciencias Salud, Ctr Invest Fisiol & Med Altura, Antofagasta, Chile
[4] Kinet K Integral Therapy & Training Ctr, Antofagasta, Chile
[5] Univ Santo Tomas, Escuela Kinesiol, Fac Salud, Lab Invest Somatosensorial & Motora, Santiago, Chile
[6] Univ Santo Tomas, Escuela Kinesiol, Fac Salud, Santiago, Chile
[7] Univ Antofagasta, Avda Univ Antofagasta 02800, Antofagasta 1240000, Chile
关键词
Ultrasonography; Reliability; Shoulder; Subacromial space;
D O I
10.1016/j.msksp.2024.102906
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Background: Ultrasonography (US) is a widely used diagnostic tool in physical therapy. One of the US variables often utilized to quantify the dimensions of the subacromial space and its association with shoulder pathology is the coracohumeral distance (CHD), however, this measurement presents diverse evidence in terms of reliability. Objectives: To assess the intra- and inter-rater reliability of both expert and non-expert raters when measuring CHD through US in asymptomatic subjects. Additionally, we determined the effect of rater experience and measurement conditions on the recording of CHD. Methods: CHD of 15 individuals were recorded from US images of the glenohumeral joint of both upper extremities in three different positions. An expert and a non-expert rater in US usage recorded three CHD measurements, after a randomization procedure. To determine intra- and inter-rater reliability, the interclass correlation coefficient (ICC) and a multivariate variance model for the effects of rater experience, joint position and time of measure were used. Standard Error of Measurement and Minimal Detectable Change was also estimated for CHD measurements. Results: Intra-rater reliability ranged 0.970 to 0.998) and Inter-rater reliability ranged 0.48 to 0.876). Joint position (F2;55 = 38.308; p < 0.001; eta 2p = 0.582) and measurement time (F2;55 = 6.019; p = 0.004; eta 2p = 0.180) effect was observed on CHD. Conclusion: Excellent intra- and poor to moderate inter-rater reliability between expert and non-expert clinicians was determined, the latter being influenced by the position of the glenohumeral joint position at the time of US recording and the time of recording the measurement.
引用
收藏
页数:5
相关论文
共 18 条
  • [1] Coracohumeral Distances and Correlation to Arm Rotation An In Vivo 3-Dimensional Biplane Fluoroscopy Study
    Brunkhorst, John P.
    Giphart, J. Erik
    LaPrade, Robert F.
    Millett, Peter J.
    [J]. ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2013, 1 (02)
  • [2] In vivo effects of two shoulder girdle motor control exercises on acromiohumeral and coracohumerai distances in healthy men
    Charry, Fernanda B.
    Martinez, Maria Jesus L.
    Rozo, Liliana
    Jurgensen, Fernando
    Guerrero-Henriquez, Juan
    [J]. JOURNAL OF MANUAL & MANIPULATIVE THERAPY, 2021, : 367 - 375
  • [3] A POWER PRIMER
    COHEN, J
    [J]. PSYCHOLOGICAL BULLETIN, 1992, 112 (01) : 155 - 159
  • [4] G*Power 3: A flexible statistical power analysis program for the social, behavioral, and biomedical sciences
    Faul, Franz
    Erdfelder, Edgar
    Lang, Albert-Georg
    Buchner, Axel
    [J]. BEHAVIOR RESEARCH METHODS, 2007, 39 (02) : 175 - 191
  • [5] Grissom R.J, 2012, EFFECT SIZES RES UNI, DOI DOI 10.4324/9781410612915
  • [6] In vivo measurements of glenohumeral distraction technique performed in three different joint positions
    Guerra-Rodriguez, Diego
    Rozo, Liliana
    Basilio, Daniel
    Guerrero-Henriquez, Juan
    [J]. JOURNAL OF MANUAL & MANIPULATIVE THERAPY, 2021, 29 (06) : 353 - 359
  • [7] Kaltenborn F., 2004, Fisioterapia Manual: Extremidades
  • [8] A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability Research
    Koo, Terry K.
    Li, Mae Y.
    [J]. JOURNAL OF CHIROPRACTIC MEDICINE, 2016, 15 (02) : 155 - 163
  • [9] Guidelines for Reporting Reliability and Agreement Studies (GRRAS) were proposed
    Kottner, Jan
    Audige, Laurent
    Brorson, Stig
    Donner, Allan
    Gajewski, Byron J.
    Hrobjartsson, Asbjorn
    Roberts, Chris
    Shoukri, Mohamed
    Streiner, David L.
    [J]. JOURNAL OF CLINICAL EPIDEMIOLOGY, 2011, 64 (01) : 96 - 106
  • [10] Determining the resting position of the glenohumeral joint in subjects who are healthy
    Lin, Hui-Ting
    Hsu, Ar-Tyan
    Chang, Guan-Liang
    Chien, Jia-rea Chang
    An, Kai-Nan
    Su, Fong Chin
    [J]. PHYSICAL THERAPY, 2007, 87 (12): : 1669 - 1682