In the paper, new detection methods that can be used to detect signals in a miniature MEMS (Micro-Electro-Mechanical System) electron microscope were presented. The methods were designed to fit the structure of the developed MEMS microscope, equipped with an electron-optical microcolumn and a scanning system based on an octupole deflector. In the experiments carried out, imaging was performed using a system of three silicon detectors placed above, below, and at the sample level and integrated with the octupole deflection system. Measurements were carried out under different pressure conditions (vacuum and atmospheric pressure) and for different detector bias voltage and electron beam energy. Good quality images were obtained using all three detectors, both in vacuum and in air. The results presented indicate that in the final implementation of the MEMS electron microscope, all three detection systems can be successfully incorporated.
引用
收藏
页数:10
相关论文
共 15 条
[1]  
de Jonge N, 2011, NAT NANOTECHNOL, V6, P695, DOI [10.1038/nnano.2011.161, 10.1038/NNANO.2011.161]
[2]   WIDE-BAND DETECTOR FOR MICRO-MICROAMPERE LOW-ENERGY ELECTRON CURRENTS [J].
EVERHART, TE ;
THORNLEY, RFM .
JOURNAL OF SCIENTIFIC INSTRUMENTS, 1960, 37 (07) :246-248
[3]  
Goldstein J., 2003, SCANNING ELECT MICRO, DOI [10.1007/978-1-4939-6676-9, DOI 10.1007/978-1-4615-0215-9]
[4]   A Comparison of Conventional Everhart-Thornley Style and In-Lens Secondary Electron Detectors-A Further Variable in Scanning Electron Microscopy [J].
Griffin, Brendan J. .
SCANNING, 2011, 33 (03) :162-173
[5]   The assembly of a fully functional microcolumn and its STEM-mode operation [J].
Kim, HS ;
Kim, DW ;
Ahn, SJ ;
Kim, YC ;
Park, SS ;
Choi, SK ;
Kim, DY .
JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2003, 43 (05) :831-835
[6]   Atmospheric Pressure Electron Detection Method for MEMS Electron Microscope [J].
Krysztof, M. ;
Bialas, M. ;
Grzebyk, T. ;
Gorecka-Drzazga, A. .
IEEE ELECTRON DEVICE LETTERS, 2022, 43 (05) :813-815
[7]   Fabrication and characterization of a miniaturized octupole deflection system for the MEMS electron microscope [J].
Krysztof, M. ;
Bialas, M. ;
Szyszka, P. ;
Grzebyk, T. ;
Gorecka-Drzazga, A. .
ULTRAMICROSCOPY, 2021, 225
[8]   Technology and parameters of thin membrane-anode for MEMS transmission electron microscope [J].
Krysztof, Michal ;
Grzebyk, Tomasz ;
Szyszka, Piotr ;
Laszczyk, Karolina ;
Drzazga, Anna Gorecka ;
Dziuban, Jan .
JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 2018, 36 (02)
[9]   Sharing of secondary electrons by in-lens and out-lens detector in low-voltage scanning electron microscope equipped with immersion lens [J].
Kumagai, Kazuhiro ;
Sekiguchi, Takashi .
ULTRAMICROSCOPY, 2009, 109 (04) :368-372
[10]   Novel microchip for in situ TEM imaging of living organisms and bio-reactions in aqueous conditions [J].
Liu, Kuo-Liang ;
Wu, Chien-Chen ;
Huang, Ying-Jung ;
Peng, Hwei-Ling ;
Chang, Hwan-You ;
Chang, Pin ;
Hsu, Long ;
Yew, Tri-Rung .
LAB ON A CHIP, 2008, 8 (11) :1915-1921