Flow-Through Amperometric Biosensor System Based on Functionalized Aryl Derivative of Phenothiazine and PAMAM-Calix-Dendrimers for the Determination of Uric Acid

被引:1
|
作者
Stoikov, Dmitry [1 ]
Ivanov, Alexey [1 ]
Shafigullina, Insiya [1 ]
Gavrikova, Milena [1 ]
Padnya, Pavel [1 ]
Shiabiev, Igor [1 ]
Stoikov, Ivan [1 ]
Evtugyn, Gennady [1 ,2 ]
机构
[1] Kazan Fed Univ, Alexander Butlerov Inst Chem, 18 Kremlevskaya St, Kazan 420008, Russia
[2] Ural Fed Univ, Chem Technol Inst, Analyt Chem Dept, 19 Mira St, Ekaterinburg 620002, Russia
来源
BIOSENSORS-BASEL | 2024年 / 14卷 / 03期
基金
俄罗斯科学基金会;
关键词
flow-through analysis; chronoamperometry; electrochemical biosensor; replaceable reactor; uricase; PAMAM-calix-dendrimers; HOST-GUEST RECOGNITION; ELECTROCHEMICAL-BEHAVIOR; SENSOR; POLYMER; SERUM;
D O I
10.3390/bios14030120
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A flow-through biosensor system for the determination of uric acid was developed on the platform of flow-through electrochemical cell manufactured by 3D printing from poly(lactic acid) and equipped with a modified screen-printed graphite electrode (SPE). Uricase was immobilized to the inner surface of a replaceable reactor chamber. Its working volume was reduced to 10 mu L against a previously reported similar cell. SPE was modified independently of the enzyme reactor with carbon black, pillar[5]arene, poly(amidoamine) dendrimers based on the p-tert-butylthiacalix[4]arene (PAMAM-calix-dendrimers) platform and electropolymerized 3,7-bis(4-aminophenylamino) phenothiazin-5-ium chloride. Introduction of the PAMAM-calix-dendrimers into the electrode coating led to a fivefold increase in the redox currents of the electroactive polymer. It was found that higher generations of the PAMAM-calix-dendrimers led to a greater increase in the currents measured. Coatings consisted of products of the electropolymerization of the phenothiazine with implemented pillar[5]arene and PAMAM-calix-dendrimers showing high efficiency in the electrochemical reduction of hydrogen peroxide that was formed in the enzymatic oxidation of uric acid. The presence of PAMAM-calix-dendrimer G2 in the coating increased the redox signal related to the uric acid assay by more than 1.5 times. The biosensor system was successfully applied for the enzymatic determination of uric acid in chronoamperometric mode. The following optimal parameters for the chronoamperometric determination of uric acid in flow-through conditions were established: pH 8.0, flow rate 0.2 mL center dot min-1, 5 U of uricase per reactor. Under these conditions, the biosensor system made it possible to determine from 10 nM to 20 mu M of uric acid with the limit of detection (LOD) of 4 nM. Glucose (up to 1 mM), dopamine (up to 0.5 mM), and ascorbic acid (up to 50 mu M) did not affect the signal of the biosensor toward uric acid. The biosensor was tested on spiked artificial urine samples, and showed 101% recovery for tenfold diluted samples. The ease of assembly of the flow cell and the low cost of the replacement parts make for a promising future application of the biosensor system in routine clinical analyses.
引用
收藏
页数:14
相关论文
共 2 条
  • [1] A Flow-Through Biosensor System Based on Pillar[3]Arene[2]Quinone and Ferrocene for Determination of Hydrogen Peroxide and Uric Acid
    Stoikov, Dmitry
    Shafigullina, Insiya
    Shurpik, Dmitry
    Stoikov, Ivan
    Evtugyn, Gennady
    CHEMOSENSORS, 2024, 12 (06)
  • [2] Flow-Through Electrochemical Biosensor with a Replaceable Enzyme Reactor and Screen-Printed Electrode for the Determination of Uric Acid and Tyrosine
    Stoikov, Dmitrii
    Ivanov, Alexey
    Shurpik, Dmitriy
    Stoikov, Ivan
    Evtugyn, Gennady
    ANALYTICAL LETTERS, 2022, 55 (08) : 1281 - 1295