Synthesis of Titanium Oxide Nanotubes Loaded with Hydroxyapatite

被引:21
|
作者
Nahum, Elinor Zadkani [1 ]
Lugovskoy, Alex [1 ]
Lugovskoy, Svetlana [1 ]
Sobolev, Alexander [1 ]
机构
[1] Ariel Univ, Dept Chem Engn, IL-4070000 Ariel, Israel
关键词
anodizing; titanium oxide nanotubes; growth kinetics; corrosion resistance; hydroxyapatite; biomedical applications; PLASMA ELECTROLYTIC OXIDATION; AMORPHOUS CALCIUM-PHOSPHATE; TIO2; NANOTUBES; ANODIZATION; KINETICS; VOLTAGE; ALLOY;
D O I
10.3390/nano13202743
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A simple method of synthesis of TiO2 nanotubes (TiNT) loaded with hydroxyapatite (HAP) is described. Such nanotubes find wide applications in various fields, including biomedicine, solar cells, and drug delivery, due to their bioactivity and potential for osseointegration. The Cp-Ti substrate was anodized at a constant voltage of 40 V, with the subsequent heat treatment at 450 degrees C. The resulting TiNT had a diameter of 100.3 +/- 2.8 nm and a length of 3.5 +/- 0.04 mu m. The best result of the growth rate of HAP in Hanks' balanced salt solution (Hanks' BSS) was obtained in calcium glycerophosphate (CG = 0.1 g/L) when precipitates formed on the bottom and walls of the nanotubes. Structural properties, surface wettability, corrosion resistance, and growth rate of HAP as an indicator of the bioactivity of the coating have been studied. X-ray diffraction (XRD), scanning electron microscope (SEM), energy dispersive spectroscopy (EDS), potentiodynamic polarization test (PPC), electrochemical impedance spectroscopy (EIS), and contact angle (CA) measurements were used to characterize HAP-loaded nanotubes (HAP-TiNT). The CA, also serving as an indirect indicator of bioactivity, was 30.4 +/- 1.1 degrees for the TiNT not containing HAP. The contact angle value for HAP-TiNT produced in 0.1 g/L CG was 18.2 +/- 1.2 degrees, and for HAP-TiNT exposed to Hanks' BSS for 7 days, the CA was 7.2 +/- 0.5 degrees. The corrosion studies and measurement of HAP growth rates after a 7-day exposure to Hanks' BSS confirmed the result that TiNT processed in 0.1 g/L of CG exhibited the most significant capacity for HAP formation compared to the other tested samples.
引用
收藏
页数:17
相关论文
共 50 条
  • [41] Titanium Oxide Nanotubes: Synthesis of Anatase Phase, Characterization and Photocatalytic Application
    Trota Filho, Jorge
    Rocco, Ana Maria
    REVISTA VIRTUAL DE QUIMICA, 2013, 5 (04) : 630 - 645
  • [42] Synthesis and characterization of titania nanotubes by anodizing of titanium in fluoride containing electrolytes
    Ahmad, Akhlaq
    Ul Haq, Ehsan
    Akhtar, Waseem
    Arshad, Muhammad
    Ahmad, Zubair
    APPLIED NANOSCIENCE, 2017, 7 (08) : 701 - 710
  • [43] Preparation and Characterization of Oxide Nanotubes on Titanium Surface for Use in Controlled Drug Release Systems
    Osak, Patrycja
    Skwarek, Sandra
    Lukowiec, Dariusz
    Przeliorz, Grzegorz
    Losiewicz, Bozena
    MATERIALS, 2024, 17 (15)
  • [44] Recent Developments in Suspension Plasma Sprayed Titanium Oxide and Hydroxyapatite Coatings
    Jaworski, R.
    Pawlowski, L.
    Pierlot, C.
    Roudet, F.
    Kozerski, S.
    Petit, F.
    JOURNAL OF THERMAL SPRAY TECHNOLOGY, 2010, 19 (1-2) : 240 - 247
  • [45] Mechanochemical synthesis of hydroxyapatite/titanium nanocomposite
    Fahami, Abbas
    Ebrahimi-Kahrizsangi, Reza
    Nasiri-Tabrizi, Bahman
    SOLID STATE SCIENCES, 2011, 13 (01) : 135 - 141
  • [46] Titanium oxide nanotubes for bone regeneration
    Suguru Kubota
    Kohei Johkura
    Kazuhiko Asanuma
    Yasumitsu Okouchi
    Naoko Ogiwara
    Katsunori Sasaki
    Tomoko Kasuga
    Journal of Materials Science: Materials in Medicine, 2004, 15 : 1031 - 1035
  • [47] Magnesium substituted hydroxyapatite coating on titanium with nanotublar TiO2 intermediate layer via electrochemical deposition
    Yan, Yajing
    Ding, Qiongqiong
    Huang, Yong
    Han, Shuguang
    Pang, Xiaofeng
    APPLIED SURFACE SCIENCE, 2014, 305 : 77 - 85
  • [48] Single-walled carbon nanotubes/hydroxyapatite coatings on titanium obtained by electrochemical deposition
    Pei, Xibo
    Zeng, Yongxiang
    He, Rui
    Li, Zhongjie
    Tian, Lingyang
    Wang, Jian
    Wan, Qianbing
    Li, Xiaoyu
    Bao, Hong
    APPLIED SURFACE SCIENCE, 2014, 295 : 71 - 80
  • [49] The enhancement of osseointegration using a graphene oxide/chitosan/hydroxyapatite composite coating on titanium fabricated by electrophoretic deposition
    Suo, Lai
    Jiang, Nan
    Wang, Yan
    Wang, Puyu
    Chen, Junyu
    Pei, Xibo
    Wang, Jian
    Wan, Qianbing
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2019, 107 (03) : 635 - 645
  • [50] Loaded titanium implant with hydroxyapatite coat -: histological observations.
    Himmlová, L
    Dorazilová, V
    Dostálová, T
    Jelínek, M
    LASER FLORENCE '99: A WINDOW ON THE LASER MEDICINE WORLD, 1999, 1 (37): : 245 - 252