Challenges and Limitation Analysis of an IoT-Dependent System for Deployment in Smart Healthcare Using Communication Standards Features

被引:7
作者
Upadhyay, Shrikant [1 ]
Kumar, Mohit [2 ]
Upadhyay, Aditi [3 ]
Verma, Sahil [4 ]
Kavita [4 ]
Kaur, Maninder [5 ]
Abu Khurma, Ruba A. [6 ]
Castillo, Pedro A. [7 ]
机构
[1] Cambridge Inst Technol CIT, Dept Elect & Commun Engn, Tatisilwai 835103, India
[2] MIT Art Design & Technol Univ, Dept IT, Pune 412201, India
[3] Jaipur Natl Univ, Sch Engn, Dept Elect & Commun Engn, Jaipur 302017, India
[4] Uttranchal Univ, Dept Comp Sci & Engn, Dehra Dun 248007, India
[5] Guru Gobind Singh Coll Women, Dept Comp Sci & Applicat, Chandigarh 160019, India
[6] Al Ahliyya Amman Univ, Fac Informat Technol, Comp Sci Dept, Amman 19328, Jordan
[7] Univ Granada, Dept Comp Engn Automat & Robot, ETSIIT, Granada 18012, Spain
关键词
healthcare; IoT; wearable sensors; communication standard; cloud; security; WEARABLE DEVICE; ACCESS-CONTROL; SENSOR; INTERNET; THINGS; ARCHITECTURE; RELIABILITY; FRAMEWORK; NETWORK; ARMBAND;
D O I
10.3390/s23115155
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The use of IoT technology is rapidly increasing in healthcare development and smart healthcare system for fitness programs, monitoring, data analysis, etc. To improve the efficiency of monitoring, various studies have been conducted in this field to achieve improved precision. The architecture proposed herein is based on IoT integrated with a cloud system in which power absorption and accuracy are major concerns. We discuss and analyze development in this domain to improve the performance of IoT systems related to health care. Standards of communication for IoT data transmission and reception can help to understand the exact power absorption in different devices to achieve improved performance for healthcare development. We also systematically analyze the use of IoT in healthcare systems using cloud features, as well as the performance and limitations of IoT in this field. Furthermore, we discuss the design of an IoT system for efficient monitoring of various healthcare issues in elderly people and limitations of an existing system in terms of resources, power absorption and security when implemented in different devices as per requirements. Blood pressure and heartbeat monitoring in pregnant women are examples of high-intensity applications of NB-IoT (narrowband IoT), technology that supports widespread communication with a very low data cost and minimum processing complexity and battery lifespan. This article also focuses on analysis of the performance of narrowband IoT in terms of delay and throughput using single- and multinode approaches. We performed analysis using the message queuing telemetry transport protocol (MQTTP), which was found to be efficient compared to the limited application protocol (LAP) in sending information from sensors.
引用
收藏
页数:25
相关论文
共 109 条
[81]   A Pressure Sensing System for Heart Rate Monitoring with Polymer-Based Pressure Sensors and an Anti-Interference Post Processing Circuit [J].
Shu, Yi ;
Li, Cheng ;
Wang, Zhe ;
Mi, Wentian ;
Li, Yuxing ;
Ren, Tian-Ling .
SENSORS, 2015, 15 (02) :3224-3235
[82]   A Novel Patient-Centric Architectural Framework for Blockchain-Enabled Healthcare Applications [J].
Singh, Akhilendra Pratap ;
Pradhan, Nihar Ranjan ;
Luhach, Ashish K. ;
Agnihotri, Sivansu ;
Jhanjhi, Noor Zaman ;
Verma, Sahil ;
Kavita ;
Ghosh, Uttam ;
Roy, Diptendu Sinha .
IEEE TRANSACTIONS ON INDUSTRIAL INFORMATICS, 2021, 17 (08) :5779-5789
[83]  
Singh Dalwinder, 2021, 2021 2nd International Conference on Computation, Automation and Knowledge Management (ICCAKM), P107, DOI 10.1109/ICCAKM50778.2021.9357765
[84]  
Singh Dalwinder, 2020, 2020 4th International Conference on Trends in Electronics and Informatics (ICOEI). Proceedings, P977, DOI 10.1109/ICOEI48184.2020.9143043
[85]  
Singh Heer M., 2021, J CYBERSECUR INF MAN, V5, P5, DOI DOI 10.54216/JCIM.050201
[86]  
Sood M., 2018, NEW TRENDS COMPUTATI, DOI [10.1007/978-3-030-41862-5_52, DOI 10.1007/978-3-030-41862-5_52]
[87]  
Srivastava Akshat, 2020, IOP Conference Series: Materials Science and Engineering, V993, DOI 10.1088/1757-899X/993/1/012061
[88]   RETRACTED: An ontology-driven personalized food recommendation in IoT-based healthcare system (Retracted article. See vol. 79, pg. 5847, 2023) [J].
Subramaniyaswamy, V ;
Manogaran, Gunasekaran ;
Logesh, R. ;
Vijayakumar, V. ;
Chilamkurti, Naveen ;
Malathi, D. ;
Senthilselvan, N. .
JOURNAL OF SUPERCOMPUTING, 2019, 75 (06) :3184-3216
[89]   BioWatch: A Noninvasive Wrist-Based Blood Pressure Monitor That Incorporates Training Techniques for Posture and Subject Variability [J].
Thomas, Simi Susan ;
Nathan, Viswam ;
Zong, Chengzhi ;
Soundarapandian, Karthikeyan ;
Shi, Xiangrong ;
Jafari, Roozbeh .
IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2016, 20 (05) :1291-1300
[90]   Power allocation scheme for maximizing spectral efficiency and energy efficiency tradeoff for uplink NOMA systems in B5G/6G [J].
Tian, Xinji ;
Huang, Yuxia ;
Verma, Sahil ;
Jin, Machao ;
Ghosh, Uttam ;
Rabie, Khaled M. ;
Dinh-Thuan Do .
PHYSICAL COMMUNICATION, 2020, 43