Surface guided electron FLASH radiotherapy for canine cancer patients

被引:4
作者
Mannerberg, Annika [1 ]
Konradsson, Elise [1 ]
Kugele, Malin [1 ,2 ]
Edvardsson, Anneli [1 ,2 ]
Kadhim, Mustafa [2 ]
Ceberg, Crister [1 ]
Peterson, Kristoffer [2 ,3 ]
Thomasson, Hanna-Maria [2 ]
Arendt, Maja L. [4 ]
Borresen, Betina [4 ]
Jensen, Kristine Bastholm [5 ]
Ceberg, Sofie [1 ]
机构
[1] Lund Univ, Med Radiat Phys, Lund, Sweden
[2] Skane Univ Hosp, Dept Hematol Oncol & Radiat Phys, Lund, Sweden
[3] Univ Oxford, MRC Oxford Inst Radiat Oncol, Dept Oncol, Oxford, England
[4] Univ Copenhagen, Dept Vet Clin Sci, Frederiksberg, Denmark
[5] Veterinarhuset Oresund, Limhamn, Sweden
关键词
FLASH; motion management; surface guided radiotherapy; RADIATION-THERAPY;
D O I
10.1002/mp.16453
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundDuring recent years FLASH radiotherapy (FLASH-RT) has shown promising results in radiation oncology, with the potential to spare normal tissue while maintaining the antitumor effects. The high speed of the FLASH-RT delivery increases the need for fast and precise motion monitoring to avoid underdosing the target. Surface guided radiotherapy (SGRT) uses surface imaging (SI) to render a 3D surface of the patient. SI provides real-time motion monitoring and has a large scanning field of view, covering off-isocentric positions. However, SI has so far only been used for human patients with conventional setup and treatment. PurposeThe aim of this study was to investigate the performance of SI as a motion management tool during electron FLASH-RT of canine cancer patients. MethodsTo evaluate the SI system's ability to render surfaces of fur, three fur-like blankets in white, grey, and black were used to imitate the surface of canine patients and the camera settings were optimized for each blanket. Phantom measurements using the fur blankets were carried out, simulating respiratory motion and sudden shift. Respiratory motion was simulated using the QUASAR Respiratory Motion Phantom with the fur blankets placed on the phantom platform, which moved 10 mm vertically with a simulated respiratory period of 4 s. Sudden motion was simulated with an in-house developed phantom, consisting of a platform which was moved vertically in a stepwise motion at a chosen frequency. For sudden measurements, 1, 2, 3, 4, 5, 6, 7, and 10 Hz were measured. All measurements were both carried out at the conventional source-to-surface distance (SSD) of 100 cm, and in the locally used FLASH-RT setup at SSD = 70 cm. The capability of the SI system to reproduce the simulated motion and the sampling time were evaluated. As an initial step towards clinical implementation, the feasibility of SI for surface guided FLASH-RT was evaluated for 11 canine cancer patients. ResultsThe SI camera was capable of rendering surfaces for all blankets. The deviation between simulated and measured mean peak-to-peak breathing amplitude was within 0.6 mm for all blankets. The sampling time was generally higher for the black fur than for the white and grey fur, for the measurement of both respiratory and sudden motion. The SI system could measure sudden motion within 62.5 ms and detect motion with a frequency of 10 Hz. The feasibility study of the canine patients showed that the SI system could be an important tool to ensure patient safety. By using this system we could ensure and document that 10 out of 11 canine patients had a total vector offset from the reference setup position We have shown that SI can be used for surface guided FLASH-RT of canine patients. The SI system is currently not fast enough to interrupt a FLASH-RT beam while irradiating but with the short sampling time sudden motion can be detected. The beam can therefore be held just prior to irradiation, preventing treatment errors such as underdosing the target.
引用
收藏
页码:4047 / 4054
页数:8
相关论文
共 23 条
  • [1] The role of surface-guided radiation therapy for improving patient safety
    Al-Hallaq, Hania
    Batista, Vania
    Kugele, Malin
    Ford, Eric
    Viscariello, Natalie
    Meyer, Juergen
    [J]. RADIOTHERAPY AND ONCOLOGY, 2021, 163 : 229 - 236
  • [2] AAPM task group report 302: Surface-guided radiotherapy
    Al-Hallaq, Hania A.
    Cervino, Laura
    Gutierrez, Alonso N.
    Havnen-Smith, Amanda
    Higgins, Susan A.
    Kugele, Malin
    Padilla, Laura
    Pawlicki, Todd
    Remmes, Nicholas
    Smith, Koren
    Tang, Xiaoli
    Tome, Wolfgang A.
    [J]. MEDICAL PHYSICS, 2022, 49 (04) : E82 - E112
  • [3] Clinical paradigms and challenges in surface guided radiation therapy: Where do we go from here?
    Batista, Vania
    Meyer, Juergen
    Kugele, Malin
    Al-Hallaq, Hania
    [J]. RADIOTHERAPY AND ONCOLOGY, 2020, 153 : 34 - 42
  • [4] Dose- and Volume-Limiting Late Toxicity of FLASH Radiotherapy in Cats with Squamous Cell Carcinoma of the Nasal Planum and in Mini Pigs
    Bley, Carla Rohrer
    Wolf, Friederike
    Jorge, Patrik Goncalves
    Grilj, Veljko
    Petridis, Ioannis
    Petit, Benoit
    Boehlen, Till T.
    Moeckli, Raphael
    Limoli, Charles
    Bourhis, Jean
    Meier, Valeria
    Vozenin, Marie-Catherine
    [J]. CLINICAL CANCER RESEARCH, 2022, 28 (17) : 3814 - 3823
  • [5] Normal Tissue Sparing by FLASH as a Function of Single-Fraction Dose: A Quantitative Analysis
    Boehlen, Till Tobias
    Germond, Jean-Francois
    Bourhis, Jean
    Vozenin, Marie-Catherine
    Ozsahin, Esat Mahmut
    Bochud, Francois
    Bailat, Claude
    Moeckli, Raphael
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2022, 114 (05): : 1032 - 1044
  • [6] Treatment of a first patient with FLASH-radiotherapy
    Bourhis, Jean
    Sozzi, Wendy Jeanneret
    Jorge, Patrik Goncalves
    Gaide, Olivier
    Bailat, Claude
    Duclos, Frederic
    Patin, David
    Ozsahin, Mahmut
    Bochud, Francois
    Germond, Jean-Francois
    Moeckli, Raphael
    Vozenin, Marie-Catherine
    [J]. RADIOTHERAPY AND ONCOLOGY, 2019, 139 : 18 - 22
  • [7] Optical Surface Scanning for Patient Positioning in Radiation Therapy: A Prospective Analysis of 1902 Fractions
    Carl, G.
    Reitz, D.
    Schoenecker, S.
    Pazos, M.
    Freislederer, P.
    Reiner, M.
    Alongi, F.
    Niyazi, M.
    Ganswindt, U.
    Belka, C.
    Corradini, S.
    [J]. TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2018, 17
  • [8] Accuracy of real-time respiratory motion tracking and time delay of gating radiotherapy based on optical surface imaging technique
    Chen, Li
    Bar, Sen
    Li, Guangjun
    Li, Zhibin
    Xiao, Qing
    Bai, Long
    Li, Changhu
    Xian, Lixun
    Hu, Zhenyao
    Dai, Guyu
    Wang, Guangyu
    [J]. RADIATION ONCOLOGY, 2020, 15 (01)
  • [9] Delivery efficiency of an Elekta linac under gated operation
    Cui, Guoqiang
    Housley, David J.
    Chen, Fan
    Mehta, Vivek K.
    Shepard, David M.
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2014, 15 (05): : 2 - 11
  • [10] Characteristics of gated treatment using an optical surface imaging and gating system on an Elekta linac
    Freislederer, Philipp
    Reiner, Michael
    Hoischen, Winfried
    Quanz, Anton
    Heinz, Christian
    Walter, Franziska
    Belka, Claus
    Soehn, Matthias
    [J]. RADIATION ONCOLOGY, 2015, 10