Electrochemical urea biosensor based on Proteus mirabilis urease immobilized over polyaniline PANi-Glassy carbon electrode

被引:7
作者
Atailia, Sara [1 ]
Baraket, Abdoullatif [2 ]
Rabai, Selma [1 ]
Benounis, Messaoud [1 ]
Jaffrezic, Nicole [2 ]
Araar, Hala [1 ]
Nait-Bouda, Abdelyamine [3 ]
Boumaza, Abdecharif [4 ]
Errachid, Abdelhamid [2 ]
Houhamdi, Moussa [5 ]
机构
[1] Univ Abbes Laghrour, Fac Sci & Technol, Lab Sensors Instrumentat & Proc LCIP, Khenchela, Algeria
[2] Univ Lyon, Inst Analyt Sci ISA, 5 Rue La Doua, F-69100 Lyon, France
[3] Ctr Dev Adv Technol CDTA, Algiers, Algeria
[4] Univ Abbes Laghrour, Fac Sci & Technol, Lab Properties & Interatom Interact LASPI2A, Khenchela, Algeria
[5] Univ 8 May 1945, Fac SNV STU, Lab Biol Water & Environm LBEE, Guelma, Algeria
基金
欧盟地平线“2020”;
关键词
cyclic voltammetry; glassy carbon electrode; polyaniline PANi; polymer; Proteus mirabilis; urea; urease enzyme; INHIBITIVE DETERMINATION; POTENTIOMETRIC BIOSENSOR; PARTIAL-PURIFICATION; KINETIC-PARAMETERS; HEAVY-METALS; DEHYDROGENASE; NANOPARTICLES; COPOLYMER; MEMBRANE; MILK;
D O I
10.1002/elan.202200502
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study, a novel, sensitive electrochemical enzyme-based biosensor for urea detection was presented. This biosensor combines a three-electrode system consisting of a classic Glassy Carbon Electrode (GCE) as the working electrode, a platinum counter electrode, and Ag/AgCl as the reference electrode. To construct this urea platform, a GCE was modified with a polyaniline (PANi) film. Then, bacterial urease from Proteus mirabilis was immobilized on the modified GCE (P-m-Urease-PANi-GCE). For the characterization of surface modification, Cyclic Voltammetry (CV) and Scanning Electron Microscope (SEM) were applied, while the Square Wave Voltammetry (SWV) technique was performed for urea detection. The main analytical characteristics of the P-m-Urease-PANi-GCE biosensor showed a good linear range from 0.1 to 10 mM of urea, a limit of detection (LOD) of 0.1 mM, a Michaelis-Menten K-m of 0.23 mM, and a sensitivity value 46 mu A/mM/cm(2). This biosensor allows the detection of urea in solutions, and it could be improved for further medical, environmental, or engineering applications.
引用
收藏
页数:14
相关论文
共 80 条
[21]   Extraction, purification, kinetic and thermodynamic properties of urease from germinating Pisum Sativum L. seeds [J].
EL-Hefnawy, Mohamed E. ;
Sakran, Mohamed ;
Ismail, Ali I. ;
Aboelfetoh, Eman Fahmy .
BMC BIOCHEMISTRY, 2014, 15
[22]   New analytical approach to the insulator-metal transition in conductive polyaniline [J].
Fedorko, P. ;
Trznadel, M. ;
Pron, A. ;
Djurado, D. ;
Planes, J. ;
Travers, J. P. .
SYNTHETIC METALS, 2010, 160 (15-16) :1668-1671
[23]   Electrochemical Deposition and Properties of Polyaniline Films on Carbon and Precious Metal Surfaces in Perchloric Acid/Acetonitrile [J].
Fomo, Gertrude ;
Waryo, Tesfaye T. ;
Baker, Priscilla ;
Iwuoha, Emmanuel I. .
INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2016, 11 (12) :10347-10361
[24]   Coimmobilization of urease and glutamate dehydrogenase in electrochemically prepared polypyrrole-polyvinyl sulfonate films [J].
Gambhir, A ;
Gerard, M ;
Mulchandani, AK ;
Malhotra, BD .
APPLIED BIOCHEMISTRY AND BIOTECHNOLOGY, 2001, 96 (1-3) :249-257
[25]   Kinetic parameters of urease immobilized on modified acrylonitrile copolymer membranes in the presence and absence of Cu(II) ions [J].
Godjevargova, T ;
Gabrovska, K .
MACROMOLECULAR BIOSCIENCE, 2005, 5 (05) :459-466
[26]   Novel potentiometric sensors based on polysulfone immobilized metallothioneins as metal-ionophores [J].
Gonzalez-Bellavista, Anna ;
Atrian, Silvia ;
Munoz, Maria ;
Capdevila, Merce ;
Fabregas, Esteve .
TALANTA, 2009, 77 (04) :1528-1533
[27]  
Guevarra J., 2009, IRUE PROGRAMM, P154
[28]   A UREA-SPECIFIC ENZYME ELECTRODE [J].
GUILBAULT, GG ;
MONTALVO, JG .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1969, 91 (08) :2164-+
[29]  
Gupta B, 2010, BIOSENSORS, P93
[30]  
Gvodenovic M. M., 2011, ELECTROPOLYMERIZATIO, P77