A Novel IMFET Biosensor Strategy for Interleukin-10 Quantification for Early Screening Heart Failure Disease in Saliva

被引:4
作者
Ben Halima, Hamdi [1 ]
Bellagambi, Francesca G. [1 ]
Hangouet, Marie [2 ]
Alcacer, Albert [3 ]
Pfeiffer, Norman [4 ]
Heuberger, Albert [5 ]
Zine, Nadia [1 ]
Bausells, Joan [3 ]
Errachid, Abdelhamid [1 ]
机构
[1] Claude Bernard Lyon 1 Univ UCBL, Inst Analyt Sci ISA UMR 5280, F-69100 Lyon, France
[2] French Natl Ctr Sci Res CNRS, Inst Analyt Sci ISA UMR 5280, F-69100 Lyon, France
[3] CSIC, Inst Microelect Barcelona IMB CNM, Campus UAB, Barcelona 08193, Spain
[4] Fraunhofer Inst Integrated Circuits, Fraunhofer IIS, D-91058 Erlangen, Germany
[5] Friedrich Alexander Univ Erlangen Nurnberg FAU, Informat Technol LIKE, D-91058 Erlangen, Germany
基金
欧盟地平线“2020”;
关键词
IMFET; Interleukin-10; electrochemical impedance spectroscopy; Saliva analysis; Heart failure; TNF-ALPHA; IL-10; CYTOKINES;
D O I
10.1002/elan.202200141
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We propose a salivary Interleukin-10 detection strategy as part of an easily integrable Lab-on-Chip and Point-of-Care IMFET for multi-detection Heart Failure (HF) biomarkers. Our developed IMFET showed good linearity between increasing IL-10 concentration and the charge transfer resistance in both standard solutions and real saliva samples with a LOD of 0.02 pg mL(-1). Moreover, the cross-selectivity study showed that the developed IMFET was highly selective towards IL-10 against other HF biomarkers. The precision of our IMFET was also evaluated, and the difference between the determined IL-10 concentration using the standard addition method and its expected one is<20 %.
引用
收藏
页数:9
相关论文
共 31 条
[1]   Starve a fever to heal a heart? Interleukin-18 gives new meaning to an old adage [J].
Akar, Fadi G. .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2016, 311 (02) :H311-H312
[2]   A fully integrated electrochemical biosensor platform fabrication process for cytokines detection [J].
Baraket, Abdoullatif ;
Lee, Michael ;
Zine, Nadia ;
Sigaud, Monique ;
Bausells, Joan ;
Errachid, Abdelhamid .
BIOSENSORS & BIOELECTRONICS, 2017, 93 :170-175
[3]  
Bausells J., 2021, ELSA, DOI [10.1002/elsa.202100138, DOI 10.1002/ELSA.202100138]
[4]   Determination of salivary α-amylase and cortisol in psoriatic subjects undergoing the Trier Social Stress Test [J].
Bellagambi, F. G. ;
Degano, I. ;
Ghimenti, S. ;
Lomonaco, T. ;
Dini, V. ;
Romanelli, M. ;
Mastorci, F. ;
Gemignani, A. ;
Salvo, P. ;
Fuoco, R. ;
Di Francesco, F. .
MICROCHEMICAL JOURNAL, 2018, 136 :177-184
[5]   Determination and stability of N-terminal pro-brain natriuretic peptide in saliva samples for monitoring heart failure [J].
Bellagambi, Francesca G. ;
Petersen, Christina ;
Salvo, Pietro ;
Ghimenti, Silvia ;
Franzini, Maria ;
Biagini, Denise ;
Hangouet, Marie ;
Trivella, Maria Giovanna ;
Di Francesco, Fabio ;
Paolicchi, Aldo ;
Errachid, Abdelhamid ;
Fuoco, Roger ;
Lomonaco, Tommaso .
SCIENTIFIC REPORTS, 2021, 11 (01)
[6]   Saliva sampling: Methods and devices. An overview [J].
Bellagambi, Francesca G. ;
Lomonaco, Tommaso ;
Salvo, Pietro ;
Vivaldi, Federico ;
Hangouet, Marie ;
Ghimenti, Silvia ;
Biagini, Denise ;
Di Francesco, Fabio ;
Fuoco, Roger ;
Errachid, Abdelhamid .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2020, 124
[7]   Immuno field-effect transistor (ImmunoFET) for detection of salivary cortisol using potentiometric and impedance spectroscopy for monitoring heart failure [J].
Ben Halima, Hamdi ;
Bellagambi, Francesca G. ;
Brunon, Fabien ;
Alcacer, Albert ;
Pfeiffer, Norman ;
Heuberger, Albert ;
Hangouet, Marie ;
Zine, Nadia ;
Bausells, Joan ;
Errachid, Abdelhamid .
TALANTA, 2023, 257
[8]   A silicon nitride ISFET based immunosensor for tumor necrosis factor-alpha detection in saliva. A promising tool for heart failure monitoring [J].
Ben Halima, Hamdi ;
Bellagambi, Francesca G. ;
Alcacer, Albert ;
Pfeiffer, Norman ;
Heuberger, Albert ;
Hangouet, Marie ;
Zine, Nadia ;
Bausells, Joan ;
Elaissari, Abdelhamid ;
Errachid, Abdelhamid .
ANALYTICA CHIMICA ACTA, 2021, 1161
[9]   Saliva as a non-invasive tool for monitoring oxidative stress in swimmers athletes performing a VO2max cycle ergometer test [J].
Biagini, Denise ;
Lomonaco, Tommaso ;
Ghimenti, Silvia ;
Fusi, Jonathan ;
Cerri, Eugenio ;
De Angelis, Francesca ;
Bellagambi, Francesca Giuseppa ;
Oger, Camille ;
Galano, Jean Marie ;
Bramanti, Emilia ;
Franzoni, Ferdinando ;
Fuoco, Roger ;
Di Francesco, Fabio .
TALANTA, 2020, 216
[10]   Direct Patterning of Anti-Human Serum Albumin Antibodies on Aldehyde-Terminated Silicon Nitride Surfaces for HSA Protein Detection [J].
Caballero, David ;
Samitier, Josep ;
Bausells, Joan ;
Errachid, Abdelhamid .
SMALL, 2009, 5 (13) :1531-1534