Lightly reinforced concrete walls in formwork blocks for the combined seismic and energy retrofit of masonry structures

被引:2
作者
Caprili, Silvia [1 ]
Chellini, Giuseppe [1 ]
Mattei, Francesca [1 ]
Salvatore, Walter [1 ]
Simonetti, Gemma [2 ]
Badalassi, Massimo [3 ]
机构
[1] Univ Pisa, Dept Civil & Ind Engn, Largo L Lazzarino 1, I-56122 Pisa, Italy
[2] Municipal Chiusdino, Piazza Plebiscito 2, I-53012 Chiusdino, Siena, Italy
[3] SITA Engn Srl, Pisa, Italy
关键词
Seismic retrofit; Lightly reinforced concrete walls; Formwork blocks; Energy refurbishment; Seismic performance;
D O I
10.1016/j.engstruct.2024.117573
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In recent years the interest is arising towards systems for the combined structural and energy retrofit of existing structures. In the present paper a retrofit system consisting in a lightly reinforced concrete wall realized within formwork blocks in expanded clay is proposed; the shape of the blocks allows the introduction of an insulation layer with high isolation capacity. The system is conceived to work in parallel with the existing masonry structure: the realized reinforced concrete wall acts as a shear panel devoted to carry on the horizontal seismic actions, being the existing masonry walls in still in force to sustain vertical loads. Opportune connections are realized in correspondence of the horizontal floors' levels to transfer only the horizontal actions. Conceptual design, together with application to a real case study existing masonry building that allows to size and detail the panel, is presented. The results of experimental tests with horizontal forces on the proposed system are shown, as well as the calibration of a simple model able to estimate its dissipative performance as function of structural details and material properties.
引用
收藏
页数:21
相关论文
共 38 条
[1]  
[Anonymous], 2019, Italiano Annuario Statistico
[2]  
[Anonymous], 2019, GU Serie Generale
[3]  
[Anonymous], 2005, Design of steel structures-Part 1.1: General rules and rules for buildings. EN 1993-1-1:2005
[4]  
[Anonymous], Directive (EU) 2018 of the European Parliament and of the Council of 30 May 2018 amending Directive 2010/31/EU on the energy performance of buildings and Directive 2012/27/EU on energy efficiency 17
[5]   Innovative seismic and energy retrofitting of wall envelopes using prefabricated textile-reinforced concrete panels with an embedded capillary tube system [J].
Baek, E. ;
Pohoryles, D. A. ;
Kallioras, S. ;
Bournas, D. A. ;
Choi, H. ;
Kim, T. .
ENGINEERING STRUCTURES, 2022, 265
[6]   Masonry wall panels retrofitted with thermal-insulating GFRP-reinforced jacketing [J].
Borri, Antonio ;
Corradi, Marco ;
Sisti, Romina ;
Buratti, Cinzia ;
Belloni, Elisa ;
Moretti, Elisa .
MATERIALS AND STRUCTURES, 2016, 49 (10) :3957-3968
[7]   Concurrent seismic and energy retrofitting of RC and masonry building envelopes using inorganic textile-based composites combined with insulation materials: A new concept [J].
Bournas, Dionysios A. .
COMPOSITES PART B-ENGINEERING, 2018, 148 :166-179
[8]  
Bruneau M., 1998, Ductile design of steel structures
[9]  
D.M, 2018, Norme tecniche per Le costruzioni
[10]  
EN, EN 1998-1:2005, 2005 Eurocode 8: